Data Quality Reports for Session: 101507 User: jberinge Completed: 09/11/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D051114.3TWP/SKYRAD/C3 - tracker inoperativetwpskyradC3.00, twpskyrad20sC3.a0, twpskyrad60sC3.b1
D051115.1TWP/SMET/C3 - Upper wind sensor failuretwpsmet60sC3.b1
D051117.2TWP/SMET/C3 - RH Values Artificially Hightwpsmet60sC3.b1
D051117.3TWP/SMET/C3 - Instrument failuretwpsmet60sC3.b1
D051206.5TWP/GNDRAD/C3 - IRT malfunctiontwpgndrad60sC3.b1
D060110.3TWP/SKYRAD/C3 - IRT damagedtwpskyrad20sC3.a0, twpskyrad60sC3.b1
D060111.1TWP/GNDRAD/C3 - IRT powertwpgndrad60sC3.b1
D060630.33TWP/SKYRAD/C3 - Reprocess: Longwave Calibration errortwpskyrad60sC3.b1
D060630.36TWP/GNDRAD/C3 - Reprocess: Longwave Calibration errortwpgndrad60sC3.b1
D060818.3TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC3.b1


DQRID : D051114.3
Start DateStart TimeEnd DateEnd Time
11/14/2005045312/02/20050000
Subject:
TWP/SKYRAD/C3 - tracker inoperative
DataStreams:twpskyradC3.00, twpskyrad20sC3.a0, twpskyrad60sC3.b1
Description:
A lightning strike at Darwin removed the tracker from service.  Instruments installed on 
the tracker were rendered either inoperative or were not shaded during this time period.  
The longwave hemispheric instruments PIR1 and PIR2 appear to have been unaffected.  They 
are not suseptable to incorrect tracker operation.  The downwelling hemispheric shortwave 
PSP instrument mounted on Skyrad will not be affected by incorrect tracker operation.
Measurements:twpskyradC3.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

twpskyrad60sC3.b1:
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Minima(short_direct_normal_min)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(down_short_diffuse_hemisp_max)
  • Shortwave Direct Normal Irradiance, Pyrheliometer(short_direct_normal)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(down_short_diffuse_hemisp_min)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer,
    Standard Deviation(down_short_diffuse_hemisp_std)
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Maxima(short_direct_normal_max)
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Standard Deviation(short_direct_normal_std)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)

twpskyrad20sC3.a0:
  • Instantaneous Direct Normal Shortwave Irradiance, Pyrheliometer Thermopile
    Voltage(inst_direct_normal)
  • Instantaneous Uncorrected Downwelling Shortwave Diffuse, Shaded Pyranometer
    Thermopile Voltage(inst_diffuse)


Back To Table of Contents

DQRID : D051115.1
Start DateStart TimeEnd DateEnd Time
11/14/2005045311/15/20052215
Subject:
TWP/SMET/C3 - Upper wind sensor failure
DataStreams:twpsmet60sC3.b1
Description:
A lightning strike destroyed the upper (#1) wind sensor.
Measurements:twpsmet60sC3.b1:
  • Wind #1 direction vector average(wind1_dir_vec_avg)
  • Wind #1 speed minimum(wind1_spd_min)
  • Wind #1 speed maximum(wind1_spd_max)
  • Wind #1 speed standard deviation(wind1_spd_sd)
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Wind #1 direction standard deviation(wind1_dir_sd)


Back To Table of Contents

DQRID : D051117.2
Start DateStart TimeEnd DateEnd Time
11/14/2005045311/15/20050050
Subject:
TWP/SMET/C3 - RH Values Artificially High
DataStreams:twpsmet60sC3.b1
Description:
Lightning strike caused RH readings to be higher than reasonable (130%).
Measurements:twpsmet60sC3.b1:
  • Vapor pressure standard deviation(vappress_sd)
  • Relative humidity mean(relh_mean)
  • Relative humidity maximum(relh_max)
  • Vapor pressure mean(vappress_mean)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • Relative humidity minimum(relh_min)


Back To Table of Contents

DQRID : D051117.3
Start DateStart TimeEnd DateEnd Time
11/14/2005045311/23/20050000
Subject:
TWP/SMET/C3 - Instrument failure
DataStreams:twpsmet60sC3.b1
Description:
A lightning strike caused a failure in the ORG.  Rainfall was being continually recorded.
Measurements:twpsmet60sC3.b1:
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • Precipitation standard deviation(precip_sd)
  • precipitation minimum(precip_min)


Back To Table of Contents

DQRID : D051206.5
Start DateStart TimeEnd DateEnd Time
11/21/2005150012/05/20050100
Subject:
TWP/GNDRAD/C3 - IRT malfunction
DataStreams:twpgndrad60sC3.b1
Description:
The internal IRT power supply failed (probably due to a lightning strike on 11/14) and was 
drawing excessive current on the data logger's DC system. The problem was corrected by 
replacing the instrument with a spare.
Measurements:twpgndrad60sC3.b1:
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)


Back To Table of Contents

DQRID : D060110.3
Start DateStart TimeEnd DateEnd Time
11/13/2005231403/07/20060257
Subject:
TWP/SKYRAD/C3 - IRT damaged
DataStreams:twpskyrad20sC3.a0, twpskyrad60sC3.b1
Description:
The analog output of the IRT was damaged by a lightning strike. The problem was corrected 
by replacing the instrument with a spare. The damaged IRT was returned to the vendor for 
repair.
Measurements:twpskyrad60sC3.b1:
  • Sky/Cloud Infra-Red Temperature Minima(sky_ir_temp_min)
  • Sky/Cloud Infra-Red Temperature(sky_ir_temp)
  • Sky/Cloud Infra-Red Temperature Standard Deviation(sky_ir_temp_std)

twpskyrad20sC3.a0:
  • Instantaneous Sky/Cloud Infrared(inst_sky_ir_signal)


Back To Table of Contents

DQRID : D060111.1
Start DateStart TimeEnd DateEnd Time
12/20/2005233001/02/20062300
Subject:
TWP/GNDRAD/C3 - IRT power
DataStreams:twpgndrad60sC3.b1
Description:
The IRT failed to report after a planned power outage to add lightning protection modules 
to the AC power wiring. The problem was corrected when a loose power connection to the 
logger was found, rectified, and power restored to the logger.
Measurements:twpgndrad60sC3.b1:
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)


Back To Table of Contents

DQRID : D060630.33
Start DateStart TimeEnd DateEnd Time
05/20/2004220012/21/20052136
Subject:
TWP/SKYRAD/C3 - Reprocess: Longwave Calibration error
DataStreams:twpskyrad60sC3.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in December 2003.  
These modified procedures introduced a calibration bias in the longwave data.  The 
previous procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.                                                             
                The data collected while the incorrect procedures were in place are 
being reprocessing to remove the calibration bias.  Note, this also affected standard 
deviation, maximum and minimum data fields.
Measurements:twpskyrad60sC3.b1:
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer2(down_long_hemisp_shaded2)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer1(down_long_hemisp_shaded1)


Back To Table of Contents

DQRID : D060630.36
Start DateStart TimeEnd DateEnd Time
05/20/2004010012/21/20052137
Subject:
TWP/GNDRAD/C3 - Reprocess: Longwave Calibration error
DataStreams:twpgndrad60sC3.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in December 2003.  
These modified procedures introduced a calibration bias in the longwave data.  The 
previous procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.                                                             
                The data collected while the incorrect procedures were in place are 
being reprocessing to remove the calibration bias.  Note, this also affected standard 
deviation, maximum and minimum data fields.
Measurements:twpgndrad60sC3.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer(up_long_hemisp)


Back To Table of Contents

DQRID : D060818.3
Start DateStart TimeEnd DateEnd Time
12/02/2003000007/13/20062219
Subject:
TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC3.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC3.b1:
  • Atmospheric pressure(atmos_pressure)


Back To Table of Contents



END OF DATA