DQR ID | Subject | Data Streams Affected |
---|---|---|
D030822.10 | TWP/MWR/C2 - min/max/delta values incorrect | twpmwrlosC2.b1 |
D040920.1 | TWP/MWR/C2 - Data collection problem | twpmwrC2.00, twpmwrlosC2.b1, twpmwrtipC2.a1 |
D050310.3 | TWP/MWR/C2 - Heater problem | twpmwrlosC2.b1, twpmwrtipC2.a1, twp5mwravgC2.c1 |
D050524.2 | TWP/MWR/C2 - mixer temperature | twpmwrlosC2.b1, twpmwrtipC2.a1 |
D050928.2 | TWP/MWR/C2 - New software version (4.15) installed | twpmwrlosC2.b1, twpmwrtipC2.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/28/1998 | 0000 | 02/08/2003 | 2359 |
Subject: | TWP/MWR/C2 - min/max/delta values incorrect |
DataStreams: | twpmwrlosC2.b1 |
Description: | The values of valid_min, valid_max, and valid_delta for fields tkxc and tknd were incorrect. They should be 303, 333, and 0.5 K, respectively. |
Measurements: | twpmwrlosC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/27/2004 | 2000 | 09/24/2004 | 0219 |
Subject: | TWP/MWR/C2 - Data collection problem |
DataStreams: | twpmwrC2.00, twpmwrlosC2.b1, twpmwrtipC2.a1 |
Description: | Large, frequent data gaps occurred due to a failing laptop computer. The problem was corrected when a new computer was installed. |
Measurements: | twpmwrlosC2.b1:
twpmwrC2.00:
twpmwrtipC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/04/2005 | 2340 | 03/14/2005 | 1650 |
Subject: | TWP/MWR/C2 - Heater problem |
DataStreams: | twpmwrlosC2.b1, twpmwrtipC2.a1, twp5mwravgC2.c1 |
Description: | When the wiring of the air temperature sensor was checked the heater apparently began activating too often. |
Measurements: | twpmwrlosC2.b1:
twp5mwravgC2.c1:
twpmwrtipC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/04/2005 | 2340 | 04/19/2005 | 0242 |
Subject: | TWP/MWR/C2 - mixer temperature |
DataStreams: | twpmwrlosC2.b1, twpmwrtipC2.a1 |
Description: | When the wiring of the air temperature sensor was checked the mixer temperature unexpectedly decreased 4 degrees. It increased to its normal value when the dielectric window was replaced. The problem was probably caused by a loose and/or corroded connection. |
Measurements: | twpmwrlosC2.b1:
twpmwrtipC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2002 | 2101 | 09/15/2005 | 1424 |
Subject: | TWP/MWR/C2 - New software version (4.15) installed |
DataStreams: | twpmwrlosC2.b1, twpmwrtipC2.a1 |
Description: | A problem began with the installation of MWR.EXE version 4.12 in November 2002. The software had been upgraded from a "DOS" to a "Windows"-compiled program to address an earlier problem. The software upgrade corrected the earlier problem but introduced a new one that caused line-of-sight observing cycles to be skipped, a 15% reduction in the number of tip curves, and saturation of CPU usage. Software versions 4.13 and 4.14 also produced these problems. The new MWR software version (4.15) was installed on 9/15/2005. As a consequence of this upgrade, the tip curve frequency increased. The tip cycle time decreased from ~60s to ~50s. |
Measurements: | twpmwrlosC2.b1:
twpmwrtipC2.a1:
|