Data Quality Reports for Session: 102604 User: dholdridge Completed: 11/10/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D061003.1NSA/METTWR/C1 - All data from 10m Level Missingnsamettwr4hC1.b1
D061012.2NSA/METTWR/C1 - Missing CMH datansamettwr4hC1.b1
D061023.1NSA/METTWR/C1 - 10m level loss of powernsamettwr4hC1.b1
D061025.1NSA/METTWR/C1 - 2m T/RH probe aspirator fan failednsamettwr4hC1.b1


DQRID : D061003.1
Start DateStart TimeEnd DateEnd Time
09/25/2006223410/04/20062347
Subject:
NSA/METTWR/C1 - All data from 10m Level Missing
DataStreams:nsamettwr4hC1.b1
Description:
The winch that lowers the tower booms failed.  Manual testing of the motor and winch 
allowed the booms to be lowered briefly and then raised back into position.  A heavy freezing 
rain/icing event added extra weight to the booms.  This extra weight was suspected as the 
cause as to why the 10m boom became disconnected.  After a new motor was installed and 
all booms were lowered and re-raised the 10m level came back on line.
Measurements:nsamettwr4hC1.b1:
  • 10m Average Calculated Dew Point(DP10M_AVG)
  • 10m Average QLI Reference Temperature(RefT10m_AVG)
  • Standard Deviation of 10m Calculated Vapor Pressure(VP10M_STD)
  • 10m Average Relative Humidity(RH10M_AVG)
  • 10m Vector Averaged Wind Speed(WS10M_U_WVT)
  • 10m Average Calculated Vapor Pressure(VP10M_AVG)
  • 10m Average QLI Input Voltage(Volt10M_AVG)
  • Standard Deviation of 10m Vector Averaged Wind Direction(WD10M_SDU_WVT)
  • 10m Average Temperature(T10M_AVG)
  • Standard Deviation of 10m Relative Humidity(RH10M_STD)
  • 10m Arithmetic Mean Wind Speed(WS10M_S_WVT)
  • 10m Vector Averaged Wind Direction(WD10M_DU_WVT)
  • Standard Deviation of 10m Calculated Dew Point(DP10M_STD)
  • Standard Deviation of 10m Temperature(T10M_STD)


Back To Table of Contents

DQRID : D061012.2
Start DateStart TimeEnd DateEnd Time
10/12/2006035110/14/20060038
Subject:
NSA/METTWR/C1 - Missing CMH data
DataStreams:nsamettwr4hC1.b1
Description:
CMH data are missing.  Corrosion in the serial data line connections caused a loss of 
communication with the CMH.
Measurements:nsamettwr4hC1.b1:
  • Chilled Mirror Calculated Vapor Pressure(VPCMH)
  • Chilled Mirror Calculated Relative Humidity(CMHRH)
  • Chilled Mirror Dew Point(CMHDP)
  • Chilled Mirror Temperature(CMHTemp)
  • Chilled Mirror Calculated Saturation Vapor Pressure(SatVPCMH)


Back To Table of Contents

DQRID : D061023.1
Start DateStart TimeEnd DateEnd Time
10/18/2006184010/23/20062230
Subject:
NSA/METTWR/C1 - 10m level loss of power
DataStreams:nsamettwr4hC1.b1
Description:
The 10 meter instrument level lost power so all variables from this level are missing.
Measurements:nsamettwr4hC1.b1:
  • 10m Average Calculated Dew Point(DP10M_AVG)
  • 10m Average QLI Reference Temperature(RefT10m_AVG)
  • Standard Deviation of 10m Calculated Vapor Pressure(VP10M_STD)
  • 10m Average Relative Humidity(RH10M_AVG)
  • 10m Vector Averaged Wind Speed(WS10M_U_WVT)
  • 10m Average Calculated Vapor Pressure(VP10M_AVG)
  • 10m Average QLI Input Voltage(Volt10M_AVG)
  • Standard Deviation of 10m Vector Averaged Wind Direction(WD10M_SDU_WVT)
  • 10m Average Temperature(T10M_AVG)
  • Standard Deviation of 10m Relative Humidity(RH10M_STD)
  • 10m Arithmetic Mean Wind Speed(WS10M_S_WVT)
  • 10m Vector Averaged Wind Direction(WD10M_DU_WVT)
  • Standard Deviation of 10m Calculated Dew Point(DP10M_STD)
  • Standard Deviation of 10m Temperature(T10M_STD)


Back To Table of Contents

DQRID : D061025.1
Start DateStart TimeEnd DateEnd Time
10/18/2006224010/23/20062230
Subject:
NSA/METTWR/C1 - 2m T/RH probe aspirator fan failed
DataStreams:nsamettwr4hC1.b1
Description:
The aspirator fan for the 2m level T/RH probe failed.  This caused higher than normal 
readings for temp and RH and artificially smoothed the data.
Measurements:nsamettwr4hC1.b1:
  • 2m Average Calculated Vapor Pressure(VP2M_AVG)
  • Standard Deviation of 2m Calculated Dew Point(DP2M_STD)
  • Standard Deviation of 2m Relative Humidity(RH2M_STD)
  • 2m Average Relative Humidity(RH2M_AVG)
  • Standard Deviation of 2m Calculated Vapor Pressure(VP2M_STD)
  • 2m Average Temperature(T2M_AVG)
  • Standard Deviation of 2m Temperature(T2M_STD)
  • 2m Average Calculated Dew Point(DP2M_AVG)


Back To Table of Contents



END OF DATA