Data Quality Reports for Session: 102937 User: sbiraud Completed: 11/30/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040608.2SGP/BRS/C1 - NIP sensor failuresgpbrsC1.00, sgpbrsC1.b1, sgpbrs20sC1.a0
D050206.1SGP/BRS/C1 - Monthly SummarysgpbrsC1.b1
D050225.2SGP/BRS/C1 - Reprocess: Incorrect Calibration CoefficientssgpbrsC1.00, sgpbrsC1.b1, sgpbrs20sC1.a0
D050312.1SGP/BRS/C1 - Monthly SummarysgpbrsC1.b1
D050322.1SGP/BRS/C1 - low downwelling shortwave readingssgpbrsC1.00, sgpbrsC1.b1, sgpbrs20sC1.a0
D060630.7SGP/BRS/C1 - Reprocessed: Longwave Calibration errorsgpbrsC1.b1
D061102.1SGP/BRS/C1 - Reprocess: Calibration error in Downwelling Longwave measurementsgpbrsC1.b1, sgpbrs20sC1.a0


DQRID : D040608.2
Start DateStart TimeEnd DateEnd Time
06/02/2004173406/15/20042010
Subject:
SGP/BRS/C1 - NIP sensor failure
DataStreams:sgpbrsC1.00, sgpbrsC1.b1, sgpbrs20sC1.a0
Description:
Normal incidence values of downwelling shortwave radiation were
               reported as -9999 (missing).  The NIP instrument was damaged by
               lightning in the area near the time of failure.
Measurements:sgpbrs20sC1.a0:
  • Instantaneous Direct Normal Shortwave Irradiance, Pyrheliometer Thermopile
    Voltage(inst_direct_normal)

sgpbrsC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

sgpbrsC1.b1:
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Maxima(short_direct_normal_max)
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Standard Deviation(short_direct_normal_std)
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Minima(short_direct_normal_min)
  • Shortwave Direct Normal Irradiance, Pyrheliometer(short_direct_normal)


Back To Table of Contents

DQRID : D050206.1
Start DateStart TimeEnd DateEnd Time
12/01/2004000012/31/20040000
Subject:
SGP/BRS/C1 - Monthly Summary
DataStreams:sgpbrsC1.b1
Description:
Data quality this site-month is poor. This is due largely to the missing Upwelling
Shortwave and Upwelling Longwave the entire month. This problem has been ongoing for
several months now. DQPR # 124 asserted that the Global PSP was recording inaccurate
readings. Thus, the Global PSP was changed out on the 17th by site ops. Prior to the
17th, the Global PSP was falling below nighttime empirical limits on most nights and
there were severe 3 component failures during the day. The change out of the PSP
mitigated the severity of the 3 component failures and eliminated the nighttime empirical
limits failures. There were still substantial 3 component flags after the 17th.
Measurements:sgpbrsC1.b1:
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Ventilated Pyranometer(up_short_hemisp)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
  • Shortwave Direct Normal Irradiance, Pyrheliometer(short_direct_normal)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer(down_short_hemisp)


Back To Table of Contents

DQRID : D050225.2
Start DateStart TimeEnd DateEnd Time
08/05/2004150012/03/20041700
Subject:
SGP/BRS/C1 - Reprocess: Incorrect Calibration Coefficients
DataStreams:sgpbrsC1.00, sgpbrsC1.b1, sgpbrs20sC1.a0
Description:
Lightening strike on or near 6/2/2004 took the BRS NIP(31747E6) out of service, on or near 
6/15 the NIP was replaced and the datalogger program was changed to reflect the new 
NIP(31343E6). On 8/5/2004 the DIR (Downwelling longwave) instrument was changed out and a new 
program was loaded to reflect a new DIR.  The new program contained the original 
installed shortwave instrument calibration coefficients including NIP 31747E6. Thus from 8/5 to 
when the shortwave instruments were changed out on 12/3 the wrong s/n and calibration 
factor (i.e. 31747E6) was applied to the actual NIP(31343E6)installed at BRS C1.
Measurements:sgpbrs20sC1.a0:
  • Instantaneous Direct Normal Shortwave Irradiance, Pyrheliometer Thermopile
    Voltage(inst_direct_normal)

sgpbrsC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

sgpbrsC1.b1:
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Maxima(short_direct_normal_max)
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Standard Deviation(short_direct_normal_std)
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Minima(short_direct_normal_min)
  • Shortwave Direct Normal Irradiance, Pyrheliometer(short_direct_normal)


Back To Table of Contents

DQRID : D050312.1
Start DateStart TimeEnd DateEnd Time
01/01/2005000002/01/20050000
Subject:
SGP/BRS/C1 - Monthly Summary
DataStreams:sgpbrsC1.b1
Description:
Data quality this site-month is good. The offset in the Global PSP has been much improved, 
with an average nighttime offset of -4 W/m^2, since measures were taken on 17 DEC 2004 
to fix it. The Global PSP does not go below nighttime empirical limits all month. Global 
does fall below daytime empirical limits for significant time periods on the 2, 4, 5, 12, 
28, 30. There were still substantial 3 component flags 17 DEC 2004. The charcteristic 
three component failures are present through out the month, especially closer to the end of 
the month. The problem is about equally as bad in the morning as the evening.

The flags are usually high level yellow at their worst for any given day. Finally, there 
are the typical three component flags on the 29th as well, but these occur under cloudy 
skies. The data return to normal the next day and a cause for the problem cannot be 
determined.
Measurements:sgpbrsC1.b1:
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Shortwave Diffuse Hemispheric Irradiance, Ventilated Pyranometer(down_short_diffuse_hemisp)
  • Shortwave Direct Normal Irradiance, Pyrheliometer(short_direct_normal)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer(down_short_hemisp)


Back To Table of Contents

DQRID : D050322.1
Start DateStart TimeEnd DateEnd Time
04/18/2003000012/17/20042030
Subject:
SGP/BRS/C1 - low downwelling shortwave readings
DataStreams:sgpbrsC1.00, sgpbrsC1.b1, sgpbrs20sC1.a0
Description:
Downwelling shortwave (DS) values frequently drop below -10 W/m^2 at night, and are 
consistently 20-40 W/m^2 less than the calculated downwelling shortwave during the day in 
clear-sky conditions. Corrective maintenance on 12/17/2004 corrected this offset.  It is not 
clear which CM action corrected the problem since the DS instrument cable was grounded to 
a new location and the DS ventilator fan was found in poor condition and was replaced.  
Either of these issues could have led to the problem observed in this instrument.
Measurements:sgpbrs20sC1.a0:
  • Instantaneous Downwelling Hemispheric Shortwave, Unshaded Pyranometer Thermopile
    Voltage(inst_global)

sgpbrsC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

sgpbrsC1.b1:
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer, Maxima(down_short_hemisp_max)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer, Standard
    Deviation(down_short_hemisp_std)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer, Minima(down_short_hemisp_min)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer(down_short_hemisp)


Back To Table of Contents

DQRID : D060630.7
Start DateStart TimeEnd DateEnd Time
12/11/2003193502/16/20061903
Subject:
SGP/BRS/C1 - Reprocessed: Longwave Calibration error
DataStreams:sgpbrsC1.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in June 2004. These 
modified procedures introduced a calibration bias in the longwave data. The previous 
procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations. 

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in November 2006.
Measurements:sgpbrsC1.b1:
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer(up_long_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)


Back To Table of Contents

DQRID : D061102.1
Start DateStart TimeEnd DateEnd Time
12/11/2003192006/14/20042359
Subject:
SGP/BRS/C1 - Reprocess: Calibration error in Downwelling Longwave measurement
DataStreams:sgpbrsC1.b1, sgpbrs20sC1.a0
Description:
On 20031211 the Downwelling LW pyrgeometer was replaced but the calibrations were not 
updated.  Calibrations have been corrected in data beginning 20040615.
Measurements:sgpbrs20sC1.a0:
  • Instantaneous Downwelling Pyrgeometer Thermopile Voltage, Shaded Pyrgeometer(inst_down_long_hemisp_shaded_tp)

sgpbrsC1.b1:
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Maxima(down_long_hemisp_shaded_max)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Minima(down_long_hemisp_shaded_min)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Standard
    Deviation(down_long_hemisp_shaded_std)


Back To Table of Contents