DQRID : D050316.1
Start DateStart TimeEnd DateEnd Time
12/18/2002000003/15/20052359
Subject:
SGP/CO2/C1 - Reprocessed: User Notes
DataStreams:sgp30co2flx4mmetC1.b1
Description:
Replacement of LI-200 sensor (total downwelling shortwave radiation, variable r_tot) by a 
new LI-190 sensor (upwelling photosynthetic photon flux density, variable ppfd_up).

The new LI-190 sensor was:
- installed on December 9, 2004. 
- being tested from December 9, 2004 to December 22, 2004.
- operational after December 22, 2004.

Consequently:
1. variable "r_tot" is filled with missing values (qc_r_tot = 1) after December 9, 2004,
2. variable "ppfd_up" is filled with missing values (qc_ppfd_up = 1) prior December 22, 
2004.
Measurements:sgp30co2flx4mmetC1.b1:
  • photosynthetic photon flux density (PAR)(ppfd_up)
  • total downwelling shortwave radiation (LI-200 sensor)(r_tot)


Back To Table of Contents

DQRID : D051116.2
Start DateStart TimeEnd DateEnd Time
04/28/2004190011/16/20050000
Subject:
SGP/CO2/C1 - downwelling longwave hemispheric irradiance incorrect
DataStreams:sgp30co2flx4mmetC1.b1
Description:
A problem was identified with the downwelling longwave hemispheric irradiance (variable 
"r_down_long_hemisp") calibration of our Kipp & Zonen CNR1 radiometer. The offset of the 
instrument is believed to be incorrect over the specified time frame, and a correction of 
the problem is underway.
Measurements:sgp30co2flx4mmetC1.b1:
  • downwelling longwave hemispheric irradiance t_rad corrected(r_down_long_hemisp)


Back To Table of Contents

DQRID : D051116.3
Start DateStart TimeEnd DateEnd Time
12/18/2002000011/16/20050000
Subject:
SGP/CO2/C1 - Soil Temperature measurements
DataStreams:sgp30co2flx4mmetC1.b1
Description:
Current data quality check (qc) procedure does not catch spikes in soil temperature 
measurements. A new qc procedure is being tested and will improve the current procedure.
Measurements:sgp30co2flx4mmetC1.b1:
  • average of two lower soil temperature sensors(mean_t_soil_lower)
  • average of two middle soil temperature sensors(mean_t_soil_middle)
  • average of two upper soil temperature sensors(mean_t_soil_upper)


Back To Table of Contents