Data Quality Reports for Session: 103771 User: anderberg Completed: 01/18/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D061205.2SGP/SIRS/E24 - Spikes in datasgpsirsE24.b1, sgpsirs20sE24.a0
D061208.1SGP/SIRS/E7 - Instrument noisesgpsirsE7.b1, sgpsirs20sE7.a0


DQRID : D061205.2
Start DateStart TimeEnd DateEnd Time
11/29/2006060012/05/20061830
Subject:
SGP/SIRS/E24 - Spikes in data
DataStreams:sgpsirsE24.b1, sgpsirs20sE24.a0
Description:
The down_short_hemisp, down_long_hemisp, and upwelling_longwave showed large spikes (an 
order of magnitude) in data.  Problem corrected itself on 12/5 before the site visit on 
12/7.  It is not known why the problem did not return but instruments affected were on the 
multiplexer.  Maintenance reports it was not replaced.
Measurements:sgpsirs20sE24.a0:
  • Instantaneous Downwelling Pyrgeometer Dome Thermistor Resistance, Shaded
    Pyrgeometer(inst_down_long_shaded_dome_resist)
  • Instantaneous Upwelling Pyrgeometer Thermopile Voltage, Pyrgeometer(inst_up_long_hemisp_tp)
  • Instantaneous Downwelling Hemispheric Shortwave, Unshaded Pyranometer Thermopile
    Voltage(inst_global)
  • Instantaneous Upwelling Shortwave Irradiance, Inverted Pyranometer Thermopile
    Voltage(inst_up_short_hemisp)
  • Instantaneous Downwelling Pyrgeometer Thermopile Voltage, Shaded Pyrgeometer(inst_down_long_hemisp_shaded_tp)
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Resistance, Pyrgeometer(inst_up_long_dome_resist)
  • Instantaneous Downwelling Pyrgeometer Case Thermistor Resistance, Shaded
    Pyrgeometer(inst_down_long_shaded_case_resist)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Resistance, Pyrgeometer(inst_up_long_case_resist)

sgpsirsE24.b1:
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Temperature, Pyrgeometer(inst_up_long_dome_temp)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Minima(up_long_hemisp_min)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Standard Deviation(up_long_hemisp_std)
  • Instantaneous Downwelling Pyrgeometer Dome Thermistor Temperature, Shaded
    Pyrgeometer(inst_down_long_shaded_dome_temp)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer, Standard
    Deviation(down_short_hemisp_std)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer(down_long_hemisp_shaded)
  • Downwelling Longwave Hemispheric Net Infrared(down_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Maxima(up_long_hemisp_max)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Standard
    Deviation(down_long_hemisp_shaded_std)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer(down_short_hemisp)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Minima(down_long_hemisp_shaded_min)
  • Downwelling Longwave Hemispheric Irradiance, Shaded Pyrgeometer, Maxima(down_long_hemisp_shaded_max)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer, Maxima(down_short_hemisp_max)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyrgeometer, Minima(down_short_hemisp_min)
  • Instantaneous Downwelling Pyrgeometer Case Thermistor Temperature, Shaded
    Pyrgeometer(inst_down_long_shaded_case_temp)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Temperature, Pyrgeometer(inst_up_long_case_temp)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer(up_long_hemisp)


Back To Table of Contents

DQRID : D061208.1
Start DateStart TimeEnd DateEnd Time
10/31/2006060012/12/20062105
Subject:
SGP/SIRS/E7 - Instrument noise
DataStreams:sgpsirsE7.b1, sgpsirs20sE7.a0
Description:
Beginning around 10/31, the E7 UIR experienced an increasingly noisy signal.  The 
thermopile signal was noisy, but case and dome thermistors are well behaved.  Maintenance 
reseated the UIR cable connections on 12/12/2006 which effectively eliminated the UIR noise.

The thermopile data from the upwelling pyrgeometer is noisy with resulting irradiance 
variations of up to 5 W/m2, but doesn't appear to have a bias.
Measurements:sgpsirs20sE7.a0:
  • Instantaneous Upwelling Pyrgeometer Thermopile Voltage, Pyrgeometer(inst_up_long_hemisp_tp)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Resistance, Pyrgeometer(inst_up_long_case_resist)
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Resistance, Pyrgeometer(inst_up_long_dome_resist)

sgpsirsE7.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Maxima(up_long_hemisp_max)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Standard Deviation(up_long_hemisp_std)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer(up_long_hemisp)
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Temperature, Pyrgeometer(inst_up_long_dome_temp)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Minima(up_long_hemisp_min)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Temperature, Pyrgeometer(inst_up_long_case_temp)
  • Upwelling Longwave Hemispheric Net Infrared(up_long_netir)


Back To Table of Contents



END OF DATA