Data Quality Reports for Session: 103974 User: wlchapma Completed: 01/29/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050825.3NSA/GNDRAD/C1 - Power Disconnected Brieflynsagndrad60sC1.b1
D060209.4NSA/GNDRAD/C1 - power outage affecting some GNDRAD sensorsnsagndradC1.00, nsagndrad20sC1.a0, nsagndrad60sC1.b1
D060630.39NSA/GNDRAD/C1 - Reprocess: Longwave Calibration errornsagndrad60sC1.b1
D060824.1NSA/GNDRAD/C1 - Incorrect calibration coefficientsnsagndradC1.00, nsagndrad20sC1.a0, nsagndrad20sC1.a1, nsagndrad60sC1.b1


DQRID : D050825.3
Start DateStart TimeEnd DateEnd Time
08/24/2005003008/24/20050030
Subject:
NSA/GNDRAD/C1 - Power Disconnected Briefly
DataStreams:nsagndrad60sC1.b1
Description:
Power to the Tip tower and Groundrad was disconnected briefly while ground resistance 
measurements were made. 

The following comments are from Inst. Mentor Tom Stoffel: 

The longwave and shortwave irradiances from GNDRAD were not effected by the
temporary power disconnect.  Data are good.  This would have only stopped
the ventilators for a brief time and the data do not show any signs of poor
instrument responses.

The "sfc_ir_temp" data were, however, impacted during the brief (2
readings?) interval.
Measurements:nsagndrad60sC1.b1:
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • External voltage(external_voltage)


Back To Table of Contents

DQRID : D060209.4
Start DateStart TimeEnd DateEnd Time
02/07/2006091002/07/20062350
Subject:
NSA/GNDRAD/C1 - power outage affecting some GNDRAD sensors
DataStreams:nsagndradC1.00, nsagndrad20sC1.a0, nsagndrad60sC1.b1
Description:
During the power outage the upwelling global measurement from the PSP instrument shows a 
slight increase from -5 to +0 W/m2.  This is due to removal of thermal offsets induced by 
the AC heater during the power outage.  This heater is installed within the PSP 
ventilator - it is necessary for the NSA/C1 climate.
The upwelling longwave PIR instrument is unaffected due to case and dome temperature 
corrections.
The IRT is AC powered and was not operational during this time period.
Measurements:nsagndradC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

nsagndrad20sC1.a0:
  • Instantaneous Surface Infra-Red Signal(inst_sfc_ir_signal)

nsagndrad60sC1.b1:
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Ventilated Pyranometer,
    Maxima(up_short_hemisp_max)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Ventilated Pyranometer,
    Minima(up_short_hemisp_min)
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Ventilated Pyranometer,
    Standard Deviation(up_short_hemisp_std)
  • Upwelling (10 meter) Shortwave Hemispheric Irradiance, Ventilated Pyranometer(up_short_hemisp)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)


Back To Table of Contents

DQRID : D060630.39
Start DateStart TimeEnd DateEnd Time
11/04/2004160012/21/20051855
Subject:
NSA/GNDRAD/C1 - Reprocess: Longwave Calibration error
DataStreams:nsagndrad60sC1.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in December 2003.  
These modified procedures introduced a calibration bias in the longwave data.  The 
previous procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.                                                             
                The data collected while the incorrect procedures were in place are 
being reprocessing to remove the calibration bias.  Note, this also affected standard 
deviation, maximum and minimum data fields.
Measurements:nsagndrad60sC1.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer(up_long_hemisp)


Back To Table of Contents

DQRID : D060824.1
Start DateStart TimeEnd DateEnd Time
08/11/2006193008/25/20061859
Subject:
NSA/GNDRAD/C1 - Incorrect calibration coefficients
DataStreams:nsagndradC1.00, nsagndrad20sC1.a0, nsagndrad20sC1.a1, nsagndrad60sC1.b1
Description:
BarrowC1, Gndrad. On Aug 11th the PSP-US was changed out and the Campbell program was 
changed to reflect this.  However, an old program that uses the 4 coefficient PIR cal factors 
was used. The PIR-UIR was not changed out, however, the logger program coeffs reverted 
back to the 4 Coeffcients.  The Eppley PIR-UIR coefficients for this S/N 30168F3 are :  
K0=0.0, K1(aka k)=.25253, K2= 1.0, K3=-4, Kr=0.0.
Measurements:nsagndradC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

nsagndrad20sC1.a0:
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Resistance, Pyrgeometer(inst_up_long_case_resist)
  • Instantaneous Upwelling Pyrgeometer Thermopile Voltage, Pyrgeometer(inst_up_long_hemisp_tp)
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Resistance, Pyrgeometer(inst_up_long_dome_resist)

nsagndrad60sC1.b1:
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Standard Deviation(up_long_hemisp_std)
  • NET mean(net_mean)
  • NET standard deviation(net_sd)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded mean(pir1_mean)
  • Net Radiation, Standard Deviation(net_std)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Minima(up_long_hemisp_min)
  • PIR1 unshaded minimum(pir1_min)
  • Net Radiation, Minima(net_min)
  • PIR1 unshaded maximum(pir1_max)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer,
    Maxima(up_long_hemisp_max)
  • Upwelling (10 meter) Longwave Hemispheric Irradiance, Ventilated Pyrgeometer(up_long_hemisp)
  • Net Radiation, Maxima(net_max)

nsagndrad20sC1.a1:
  • Instantaneous Upwelling Pyrgeometer Dome Thermistor Resistance, Pyrgeometer(inst_up_long_dome_resist)
  • Instantaneous Upwelling Pyrgeometer Case Thermistor Resistance, Pyrgeometer(inst_up_long_case_resist)
  • Instantaneous Upwelling Pyrgeometer Thermopile Voltage, Pyrgeometer(inst_up_long_hemisp_tp)
  • Instantaneous PIR1 uncorrected irradiance(pir1_voltage)
  • Instantaneous PIR1 dome thermistor(pir1_dome_therm)
  • Instantaneous PIR1 case thermistor(pir1_case_therm)


Back To Table of Contents



END OF DATA