Data Quality Reports for Session: 104322 User: chen660 Completed: 02/19/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D061219.2TWP/ARSCL/C2 - Reprocess: ARSCL CloudBasePrecipitation field incorrecttwparscl1clothC2.c1, twparsclcbh1clothC2.c1, twpmmcrmode01v0101clothC2.c1,
twpmmcrmode02v0071clothC2.c1, twpmmcrmode03v0091clothC2.c1
D070104.1TWP/ARSCL/C2 - Reprocess: ARSCL CloudBasePrecipitation field incorrecttwparscl1clothC2.c1, twparsclcbh1clothC2.c1


DQRID : D061219.2
Start DateStart TimeEnd DateEnd Time
09/11/2003000001/31/20052359
Subject:
TWP/ARSCL/C2 - Reprocess: ARSCL CloudBasePrecipitation field incorrect
DataStreams:twparscl1clothC2.c1, twparsclcbh1clothC2.c1, twpmmcrmode01v0101clothC2.c1,
twpmmcrmode02v0071clothC2.c1, twpmmcrmode03v0091clothC2.c1
Description:
The CloudBasePrecipitation field is incorrect and has no physical meaning.  An ARSCL 
processing error occurred when the smet60s data stream format changed, causing the wrong data 
field to be used to supply precipitation measurements to the ARSCL VAP.	The error caused 
no significant degradation in other ARSCL fields, since manual quality control corrected 
any related errors.
Measurements:twpmmcrmode03v0091clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)

twparsclcbh1clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)

twpmmcrmode02v0071clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)

twparscl1clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)

twpmmcrmode01v0101clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)


Back To Table of Contents

DQRID : D070104.1
Start DateStart TimeEnd DateEnd Time
03/01/2003000009/10/20032359
Subject:
TWP/ARSCL/C2 - Reprocess: ARSCL CloudBasePrecipitation field incorrect
DataStreams:twparscl1clothC2.c1, twparsclcbh1clothC2.c1
Description:
The CloudBasePrecipitation field is incorrect and has no physical meaning. 
An ARSCL processing error occurred when the smet60s data stream format
changed, causing the wrong data field to be used to supply precipitation
measurements to the ARSCL VAP.  The error caused no significant
degradation in other ARSCL fields, since manual quality control corrected
any related errors.
Measurements:twparsclcbh1clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)

twparscl1clothC2.c1:
  • Microwave Radiometer Wet Window/Optical Rain Gauge Cloud Base Height(CloudBasePrecipitation)


Back To Table of Contents



END OF DATA