DQR ID | Subject | Data Streams Affected |
---|---|---|
D000712.1 | SGP/OKM Overview of Automated QA - May 2000 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000809.1 | SGP/OKM Overview of Automated QA - June 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D000905.1 | SGP/OKM Overview of Automated QA - July 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D001005.1 | SGP/OKM - Overview of Automated Data Quality - August 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010531.3 | SGP/OKM - CATO station retired | sgpokmX1.01, sgp05okmX1.b1, sgp15okmX1.b1 |
D010531.4 | SGP/OKM - BEEX station added | sgpokmX1.01, sgp05okmX1.b1, sgp15okmX1.b1 |
D031016.1 | SGP/OKM/X1 - Station Change | sgpokmX1.01, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2000 | 0000 | 05/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - May 2000 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the May 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians continued site visits during May as part of "Spring Pass 2000". All stations will have received maintenance by the end of June. A cow broke through the enclosure at JAYX on May 12. I've been meaning to tell Ken Meyers I found somebody looking like they were up to no good at the nearby Pryor site: http://radar.metr.ou.edu/cgi-bin/sitephoto.cgi?site=pryo&dir=ne&info=photos Do you think we have our first suspect? (That link comes from our online site photo gallery accessible through the main Mesonet web page at http://okmesonet.ocs.ou.edu.) ================================================================ TAIR Current: #5011 SLAP Sensor reporting -7999 during most observations Added: None Resolved: #4965 JAYX Replaced cow-damaged sensor RELH Current: #4948 MAYR Sensor dropping to 0% #5006 CAMA Sensor reported near 0% RH intermittently #5010 SLAP RELH to 105% #5013 ARDM Sensor reporting over 103% #5014 ALV2 RELH to 108% Added: None Resolved: #4947 ELRE Replaced sensor reporting over 106% #4964 JAYX Replaced cow-damaged sensor WDIR Current: None Added: None Resolved: None WSPD Current: #4976 BYAR Sensor sporadically 4-5 m/s slower than speed at 9 m Added: None Resolved: #4993 CHIC Replaced noisy bearings #5023 ALTU Replaced noisy bearings PRES Current: #4980 RETR Sensor dropped 100 mb on May 18-19 Added: None Resolved: #4940 FTCB Replaced barometer stuck at 956.03 mb SRAD Current: #5009 SLAP Sensor reporting below 0 Added: #5072 KETC Monthly QA indicates 5-10% high bias Resolved: None RAIN Current: None Added: None Resolved: #4962 JAYX Repaired broken wire on cable #4988 TAHL Replaced failed switch #5026 ALTU Replaced intermittently failing switch TA9M Current: #5008 SLAP Sensor reporting below 0 Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5007 SLAP Sensor has 6 C warm bias Added: None Resolved: #4982 SALL Replaced gopher-damaged sensor TB10 Current: None Added: None Resolved: #4968 NORM Reset depth indicator; sensor was 1 cm high #4984 SALL Repaired erosion; sensor was 2 cm high TS05 Current: None Added: None Resolved: None TB05 Current: None Added: None Resolved: #4928 MEDF Corrected erosion problem #4965 NORM Reset depth indicator; sensor was 1 cm high #4985 SALL Repaired erosion; sensor was 2 cm high TS30 Current: #5005 CHIC Sensor stuck at -273.1 Added: None Resolved: #4983 SALL Replaced gopher-damaged sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: #4970 A161 Repaired loose wire RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: #5071 A136 Monthly QA indicates 3-4 C warm bias Resolved: None TS30 Current: None Added: None Resolved: #4966 A131 Replaced sensor with warm bias ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/01/2000 | 0000 | 06/30/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - June 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the June 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians completed Spring Pass 2000 on June 30. The point comparisons they performed on the TAIR, RELH, PRES, SRAD, and RAIN parameters were very useful for QA of Mesonet data. A number of sensors reporting slightly outside of the Mesonet's acceptable error ranges were identified. Many site photos were taken during Spring Pass 2000 to document vegetation cover around the bare and sod soil temperature plots, the soil heat flux sensors, and the soil moisture plots at each station. Look for those pictures along with the site visitation forms indicating the technician's notes to be available on the web next month. One more note... The monthly analysis for June identified the very heavy rains that fell over east Oklahoma during mid to late June. Westville took top honors with a June total of 17.04 inches! ================================================================ TAIR Current: None Added: None Resolved: #5011 SLAP Replaced malfunctioning sensor RELH Current: #5014 ALV2 RELH to 108% #5074 WIST RELH to 112% #5082 ADAX Sensor found to be 6% high during Spring Pass 2000 comparison #5083 BBOW Sensor found to be 20% high during Spring Pass 2000 comparison #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison #5102 KENT Sensor stuck at 0% for extended period Added: None Resolved: #4948 MAYR Replaced bad sensor #5006 CAMA Replaced bad sensor #5010 SLAP Replaced bad sensor #5013 ARDM Replaced sensor that failed mesocomp #5077 WEST Replaced sensor stuck at 0% #5087 CENT Replaced sensor found to have 5.3% high bias during spring pass 2000 #5094 MARE Replaced sensor found to have 5.9% high bias during spring pass 2000 #5110 BUFF Replaced sensor found to have 6.0% high bias during spring pass 2000 WDIR Current: None Added: None Resolved: None WSPD Current: #4976 BYAR Sensor sporadically 4-5 m/s slower than speed at 9 m Added: None Resolved: #5093 MARE Replaced sensor with noisy bearings #5120 CLAR Replaced sensor with noisy bearings PRES Current: #5086 RETR Sensor found to be .72 mb high during Spring Pass 2000 comparison Added: None Resolved: #4980 RETR Found tube clogged with bug #5046 WIST Replaced bad barometer SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5079 WASH Sensor found to be 23% high during Spring Pass 2000 comparison #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison Added: None Resolved: #5009 SLAP Corrected SRAD problems by replacing bad RH switch RAIN Current: #5078 BURN Gauge recorded no rain during radar-indicated rain event #5098 BESS Gauge found to be double-tipping on one side of bucket during Spring Pass 2000 test Added: None Resolved: #5075 PUTN Replaced bad switch TA9M Current: None Added: None Resolved: #5008 SLAP Corrected TA9M problems by cleaning corroded negative ground WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #5007 SLAP Corrected TS10 problems by cleaning corroded negative ground #5056 SKIA Tightened down power ground port TB10 Current: #5096 BOWL Sensor reports 10 C warm bias during and after rain events Added: None Resolved: #5057 SKIA Tightened down power ground port TS05 Current: None Added: None Resolved: #5058 SKIA Tightened down power ground port TB05 Current: None Added: None Resolved: #5059 SKIA Tightened down power ground port TS30 Current: #5005 CHIC Sensor stuck at -273.1 Added: None Resolved: #5012 SALL Replaced sensor reporting unreasonable values #5060 SKIA Tightened down power ground port ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5092 A181 Gauge recorded no rain during heavy rain event Added: None Resolved: #5055 A133 Repaired vandalized gauge TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: #5071 A136 Monthly QA indicates 3-4 C warm bias Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2000 | 0000 | 07/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - July 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | =============================================================== Notes: The Mesonet Technicians have begun Summer Pass 2000. All sites will be visited between July 15 and September 30. In addition to the routine maintenance that will be performed at each site, many new site photos (including updated panoramic photos) will be taken. Lightning, lightning, lightning... "The July Victims": (1) Fairview (2) Seiling (3) Grandfield (4) Medford base (5) Blackwell base (6) Kiowa Repeater (twice) ================================================================ TAIR Current: None Added: None Resolved: #5100 BEAV Replaced after found to be 0.59 C high during Spring Pass #5102 KENT Sensor found to be dangling from mount #5112 BOIS Replaced after found to be 0.7 C warm during Spring Pass #5113 PUTN Replaced after found to be 0.8 C warm during Spring Pass #5123 CLOU Replaced after found to be 0.6 C warm during Spring Pass #5134 PAWN Replaced bad sensor RELH Current: #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison #5140 MAYR Sensor reported to 108% Added: None Resolved: #5014 ALV2 Replaced after sensor rose to 108% RH #5073 SLAP Replaced after sensor reported erratic dips to 5-10% RH #5074 WIST Replaced after sensor rose to 112% RH #5076 HOOK Replaced after sensor sporadically dipped to 0%. #5082 ADAX Replaced after sensor found to be 6% high during Spring Pass #5083 BBOW Replaced after sensor found to be 20% high during Spring Pass #5085 KENT Repaired sensor found to be dangling from mount #5116 BYAR Replaced after sensor found to be 5.5% high during Spring Pass #5121 IDAB Replaced after sensor found to be 7.2% high during Spring Pass #5122 MTHE Replaced after sensor found to be 8% high during Spring Pass #5124 PERK Replaced after sensor found to be 5.1% high during Spring Pass #5126 SULP Replaced after sensor found to be 7.9% high during Spring Pass WDIR Current: None Added: None Resolved: #5167 SEIL Replaced lightning-damaged sensor WSPD Current: None Added: None Resolved: #4976 BYAR Replaced sensor with loose nut #5117 BYAR Replaced sensor with loose nose cone prop #5130 MINC Replaced nose cone due to bad bearings #5151 CENT Replaced sensor due to noisy bearings #5152 LANE Replaced sensor due to noisy bearings #5153 WIST Replaced sensor due to noisy bearings #5154 WILB Replaced sensor due to noisy bearings #5155 TALI Replaced sensor due to noisy bearings #5156 STUA Replaced sensor due to slightly noisy bearings PRES Current: #5086 RETR Sensor found to be .72 mb high during Spring Pass 2000 comparison Added: None Resolved: #5136 SALL Replaced barometer tube found to be plugged by critter SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5079 WASH Sensor found to be 23% high during Spring Pass 2000 comparison #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: None RAIN Current: #5078 BURN Gauge recorded no rain during radar-indicated rain event #5098 BESS Gauge found to be double-tipping on one side of bucket during Spring Pass 2000 test #5114 CHEY Gauge found to over-report by 6.25% during Spring Pass drip test Added: #5185 TIPT Long term analysis indicates possible under-reporting Resolved: #5142 KING Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset Added: None Resolved: #5096 BOWL Replaced sensor with 10 C warm bias TB10 Current: #5179 SALL TB10 is warmer than TB05 during all times of the day Added: None Resolved: None TS05 Current: None Added: None Resolved: #5127 ANTL Sensor found to be angled upward #5128 BRIS Corrected wiring problem TB05 Current: None Added: None Resolved: #5129 KING 1-2 inches of grass clippings removed from bare plot TS30 Current: None Added: None Resolved: #5005 CHIC Replaced wiring problem ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: #5180 A182 Sensor found to be 2.5 C warm during ARS pass Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5092 A181 Replaced bad switch #5104 A130 Replaced bad switch #5105 A149 Replaced bad switch TS05 Current: None Added: #5181 A132 Monthly QA indicates 4 C warm bias during all times of day Resolved: #5132 A136 Replaced gopher-damaged sensor #5149 A161 Replaced gopher-damaged sensor TS10 Current: None Added: #5182 A167 Monthly QA indicates 4 C warm bias during all times of day Resolved: #5131 A136 Replaced gopher-damaged sensor TS15 Current: None Added: None Resolved: #5071 A136 Replaced gopher-damaged sensor #5139 A137 Replaced reporting frequent data spikes TS30 Current: #5157 A165 Reporting erratic observations Added: None Resolved: #5137 A161 Cable chewed in half and sensor stolen ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/01/2000 | 0000 | 08/31/2000 | 2359 |
Subject: | SGP/OKM - Overview of Automated Data Quality - August 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the August 2000 Oklahoma Mesonet data. TAIR Current: None Added: None Resolved: None RELH Current: #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison Added: None Resolved: #5140 MAYR Replaced sensor exceeding 103% WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #5158 MADI Replaced sensor due to noisy bearings #5195 SALL Replaced sensor due to noisy bearings PRES Current: None Added: None Resolved: #5086 RETR Replaced sensor with high bias SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: #5079 WASH Replaced sensor with high bias RAIN Current: #5208 MTHE Gauge double-tipping on one side Added: None Resolved: #5078 BURN Removed spider web that was clogging gauge #5098 BESS Replaced gauge that was found to be double-tipping on one side of bucket during Spring Pass 2000 test #5162 TAHL Replaced gauge that was found to be double-tipping #5183 CHAN Replaced suspect switch #5184 BOWL Replaced switch found to be double-tipping #5185 TIPT Replaced gauge despite 4 success- ful drip tests because site has had longest dry period #5188 VINI Replaced gauge found to be double-tipping on one side #5202 SKIA Replaced gauge found to double- tip occasionally TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #5141 DURA Replaced sensor reporting constant 0 m/s TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset #5199 DURA Sensor reporting sporadically and 8 C warm Added: None Resolved: None TB10 Current: None Added: None Resolved: #5179 SALL Replaced bad sensor #5200 GRA2 Repaired cracked ground over bare plot TS05 Current: #5194 FAIR Sensor has 5 C cool bias since lightning strike Added: None Resolved: None TB05 Current: #5187 DURA Sensor stuck at -273.1 C Added: None Resolved: #5201 GRA2 Repaired cracked ground over bare plot TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: #5180 A182 Sensor found to be 2.5 C warm during ARS pass Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: #5181 A132 Monthly QA indicates 4 C warm bias during all times of day #5203 A167 Sensor reporting erratically and has 10 C warm bias Added: None Resolved: None TS10 Current: #5182 A167 Monthly QA indicates 4 C warm bias during all times of day Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: #5157 A165 Reporting erratic observations Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 04/19/2001 | 2359 |
Subject: | SGP/OKM - CATO station retired |
DataStreams: | sgpokmX1.01, sgp05okmX1.b1, sgp15okmX1.b1 |
Description: | The Catoosa station (CATO) was decommissioned on April 19 due to poor site exposure and the end of the EPSCOR project. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgpokmX1.01:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/OKM - BEEX station added |
DataStreams: | sgpokmX1.01, sgp05okmX1.b1, sgp15okmX1.b1 |
Description: | A new site located at Bee (BEEX) was added beginning on April 1, 2001. It does not appear in data files before that date. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgpokmX1.01:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 09/28/2003 | 2359 |
Subject: | SGP/OKM/X1 - Station Change |
DataStreams: | sgpokmX1.01, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | The Mesonet station near Marshall was moved on September 25, 2003 to improve accessiblity for the Mesonet technicians who visit and maintain the site. The new site has the code MRSH. It replaces the old Marshall site that had the code MARS. Since the latitude and longitude of the stations are included in the cdf file, users of these data should not have a problem. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
sgpokmX1.01:
|