DQR ID | Subject | Data Streams Affected |
---|---|---|
D060928.3 | SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry | sgpsondewnpnC1.b1 |
D060928.4 | NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry | nsasondewnpnC1.b1 |
D070215.4 | NSA/SONDE/C1 - Reprocess: Incorrect surface values of T & RH | nsasondewnpnC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/28/2006 | 1728 | 12/31/9999 | 2359 |
Subject: | SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The output precision of the following variables was increased 20060928 alt changed from 1m to 0.1m dp changed from 0.1degC to 0.01degC pres changed from 0.1 hPa to 0.01 hPa RH changed from 1%RH to 0.01%RH tdry changed from .1degC to 0.01degC Note that the increase in precision does not necessarily imply an increase in accuracy. Users are cautioned to continue to use their best scientific judgement when using these or any other data. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2006 | 0500 | 12/31/9999 | 2359 |
Subject: | NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry |
DataStreams: | nsasondewnpnC1.b1 |
Description: | The output precision of the following variables was increased 20060929: alt changed from 1m to 0.1m dp changed from 0.1degC to 0.01degC pres changed from 0.1 hPa to 0.01 hPa RH changed from 1%RH to 0.01%RH tdry changed from .1degC to 0.01degC Note that the increase in precision does not necessarily imply an increase in accuracy. Users are cautioned to continue to use their best scientific judgement when using these or any other data. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/29/2007 | 0526 | 01/29/2007 | 0527 |
Subject: | NSA/SONDE/C1 - Reprocess: Incorrect surface values of T & RH |
DataStreams: | nsasondewnpnC1.b1 |
Description: | It appears that because of the cold and windy conditions at the time this sounding was done the operator took the sonde inside the heated shelter just before launch. The radiosonde was at ambient conditions for only about 14 seconds before being launched. As a result, the algorithm for automatically determining the surface conditions failed. The correct surface values are T=-17.8 degC, RH=53. |
Measurements: | nsasondewnpnC1.b1:
|