DQR ID | Subject | Data Streams Affected |
---|---|---|
D011127.33 | SGP EBBR E25 - E25 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE25.a1, sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
D011127.34 | SGP EBBR E26 - Data Incorrect During 6 Month Checks | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D011206.11 | SGP EBBR E25 - E25 EBBR Wind Direction Incorrect | sgp5ebbrE25.a1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
D011206.12 | SGP EBBR E25 - E25 EBBR Wind Direction Incorrect | sgp5ebbrE25.a1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
D011206.2 | SGP EBBR E26 - Battery Voltage Low | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D011206.8 | SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrect | sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
D011206.9 | SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrect | sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
D020716.18 | SGP/EBBR/E26 - 6 Month Checks | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D020717.36 | SGP/EBBR/E25 - Reprocess: Soil Heat Flow #5 Negative Offset | sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
D020717.37 | SGP/EBBR/E26 - Measurements Zero | sgp5ebbrE26.00, sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D020717.38 | SGP/EBBR/E26 - Measurements Incorrect | sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D020717.39 | SGP/EBBR/E26 - Multiplexer 2 Failure From High Temperature | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D021113.1 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE2.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1 |
D030110.27 | SGP/EBBR/E26 - Data Incorrect during 6 month checks | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030117.26 | SGP/EBBR/E26 - Measurements zero following logger restart | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030117.27 | SGP/EBBR/E26 - Multiplexer Problem | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030117.28 | SGP/EBBR/E26 - Water in broken Net Radiometer Dome | sgp5ebbrE26.a1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030117.29 | SGP/EBBR/E26 - Battery Voltage Low | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030128.2 | SGP/EBBR/E26 - AEM Hung | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030128.3 | SGP/EBBR/E26 - Data zeros following logger restart | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030128.4 | SGP/EBBR/E26 - Left Air Temperature Incorrect | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030514.8 | SGP/EBBR/E26 - E26 EBBR Soil Heat Flow #1 Incorrect | sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030530.3 | SGP/EBBR/E27 - E27 EBBR Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR | sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030709.1 | SGP/EBBR/E25 - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE25.b1 |
D030711.2 | SGP/EBBR/E27 - Soil Heat Flow #2 Incorrect | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030711.3 | SGP/EBBR/E27 - Soil Heat Flow #4 Incorrect | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030711.4 | SGP/EBBR/E27 - Reference T Sensor Failure | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030711.5 | SGP/EBBR/E27 - Wind Direction Hung | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030711.6 | SGP/EBBR/E26 -Right Air Temperature Incorrect | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030712.23 | SGP/EBBR/E26 - 6 Month Checks | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030712.24 | SGP/EBBR/E27 - 6 Month Checks | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030728.4 | SGP/EBBR/E26 - Soil Heat Flow #5 Large Positive | sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030728.5 | SGP/EBBR/E27 - Soil Heat Flow #1 Large | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030728.6 | SGP/EBBR/E27 - Incorrect Data From Logger Restart | sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030919.11 | SGP/EBBR/E26 - Soil Storage Incorrect; Surface Fluxes Incorrect | sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
D030919.12 | SGP/EBBR/E27 - Water in Net Radiometer; Surface Fluxes are Incorrect | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030919.13 | SGP/EBBR/E27 - 15 and 30 Minute Data All Zeros | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D030922.7 | SGP/EBBR/E27 - Right Air Temperature Spiked Offscale | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D031021.3 | SGP/EBBR/E27 - Missing data during system update | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D031103.1 | SGP/EBBR/E26 - AEM Home Signals Incorrect, Surface Fluxes Incorrect | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D031117.3 | SGP/EBBR/E27 - Right Air Temperature Spiked Offscale | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D031204.21 | SGP/EBBR/E26 - 6 Month Checks | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D031204.22 | SGP/EBBR/E27 - 6 Month Checks | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D031210.1 | SGP/EBBR/E27 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
D031211.3 | SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D031222.24 | SGP/EBBR/E26 - Wind Speed Sensor Frozen By Ice Storm | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D031222.25 | SGP/EBBR/E26 - Wind Direction Sensor Frozen By Ice Storm | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D031222.26 | SGP/EBBR/E27 - Soil Temperature #3 Spike in Data | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D040304.25 | SGP/EBBR/E27 - Wind Speed Frozen Stopped By Ice | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D040304.28 | SGP/EBBR/E26 - Wind Speed Frozen Stopped By Ice | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D040304.29 | SGP/EBBR/E26 - Wind Direction Frozen Stopped By Ice | sgp5ebbrE26.b1, sgp30ebbrE26.b1 |
D040318.13 | SGP/EBBR/E27 - Soil Moisture #5 Insensitive | sgp30ebbrE27.b1 |
D040507.3 | SGP/EBBR/E27 - Right Air Temperature Incorrect | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D040706.3 | SGP/EBBR/E27 - Loose Tair Left Connections | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D040813.3 | SGP/EBBR/E27 - Data Missing or Incorrect During Battery Terminal Cleaning | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D040813.5 | SGP/EBBR/E26 - Soil Temperature #4 and Soil Heat Flow #4 Incorrect | sgp30ebbrE26.b1 |
D041222.1 | SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect | sgp5ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D041222.18 | SGP/EBBR/E26 - 6 Month Checks | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D041222.19 | SGP/EBBR/E27 - 6 Month Checks | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D041222.4 | SGP/EBBR/E26 - Low Battery Voltage - Many Measurements Incorrect | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D041222.5 | SGP/EBBR/E26 - Most Measurements Incorrect | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D050206.16 | SGP/EBBR/E26 - Wind Speed Frozen Stopped By Ice Storm | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D050206.17 | SGP/EBBR/E27 - Wind Speed Frozen Stopped By Ice Storm | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D050207.12 | SGP/EBBR/E26 - Wind Direction Frozen Stopped By Ice Storm | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D050207.13 | SGP/EBBR/E27 - Wind Direction Frozen Stopped By Ice Storm | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D050211.1 | SGP/EBBR/E26 - Aging Pressure Sensor Output Changes With Supply Voltage | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D050211.2 | SGP/EBBR/E27 - Soil Moisture #5 Incorrect | sgp30ebbrE27.b1 |
D050324.3 | SGP/EBBR/E26 - Incorrect soil type coefficients used | sgp30ebbrE26.b1 |
D050413.6 | SGP/EBBR/E27 - SM2 Coefficients Incorect | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D050719.15 | SGP/EBBR/E26 - Improved EBBR CR10 Program | sgp30ebbrE26.b1 |
D050719.16 | SGP/EBBR/E27 - Improved EBBR CR10 Program | sgp30ebbrE27.b1 |
D051106.14 | SGP/EBBR/E26 - All E26 EBBR Data Missing | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D051106.15 | SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D051106.16 | SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredt | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D051106.17 | SGP/EBBR/E27 - All E27 EBBR Data is Missing | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D051106.30 | SGP/EBBR/E26 - Average Soil Heat Flux Incorrect | sgp30ebbrE26.b1 |
D051106.31 | SGP/EBBR/E27 - Average Soil Heat Flux Incorrect | sgp30ebbrE27.b1 |
D051112.10 | SGP/EBBR/E27 - metadata corrections | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D051112.9 | SGP/EBBR/E26 - metadata corrections | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D051115.10 | SGP/EBBR/E25 - metadata errors | sgp15ebbrE25.b1, sgp30ebbrE25.b1 |
D051222.1 | SGP/EBBR/E26 - Data Suspect During Low Supply Voltage | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D060425.1 | SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrect | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D060501.26 | SGP/EBBR/E26 - Measurements Incorrect | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D060501.27 | SGP/EBBR/E27 - Flux and Gradient Measurements Incorrect | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D060508.3 | SGP/EBBR/E27 - Instrument problem, Loose connections | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D060712.1 | SGP/EBBR/E27 - Field fire burned AEM | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D060809.1 | SGP/EBBR/E27 - Sensible, Latent, and Average Soil Heat Fluxes Sometimes Incorrect | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D060809.2 | SGP/EBBR/E27 - Low Battery Condition | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D060818.11 | SGP/EBBR/E27 - Most Measurements Suspect | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D060818.13 | SGP/EBBR/E27 - Battery Voltage Problem - Measurements Incorrect | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D061114.10 | SGP/EBBR/E26 - Missing Data | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/04/2001 | 1530 | 04/04/2001 | 1631 |
10/17/2001 | 1705 | 10/17/2001 | 1811 |
Subject: | SGP EBBR E25 - E25 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE25.a1, sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE25.a1:
sgp30ebbrE25.b1:
sgp15ebbrE25.b1:
sgp30ebbrE25.a1:
sgp5ebbrE25.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/05/2001 | 1415 | 04/05/2001 | 1546 |
10/16/2001 | 1750 | 10/16/2001 | 1921 |
Subject: | SGP EBBR E26 - Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/2001 | 0845 | 05/30/2001 | 1801 |
Subject: | SGP EBBR E25 - E25 EBBR Wind Direction Incorrect |
DataStreams: | sgp5ebbrE25.a1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
Description: | The wind direction was incorrect at a constant 135 degrees during the indicated period. |
Measurements: | sgp30ebbrE25.b1:
sgp30ebbrE25.a1:
sgp5ebbrE25.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/30/2001 | 0605 | 07/11/2001 | 1631 |
Subject: | SGP EBBR E25 - E25 EBBR Wind Direction Incorrect |
DataStreams: | sgp5ebbrE25.a1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
Description: | The wind direction was incorrect at close to 0 degrees during the indicated period. The sensor was replaced to resolve the problem. |
Measurements: | sgp30ebbrE25.b1:
sgp30ebbrE25.a1:
sgp5ebbrE25.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 08/23/2001 | 1530 |
Subject: | SGP EBBR E26 - Battery Voltage Low |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The battery voltage often dropped below 10.5 volts. All data for voltages below 10.5 volts should be considered to be incorrect. See the 15 minute data files, which contain the battery voltage, to determine when the data was incorrect. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/18/2001 | 1645 | 04/18/2001 | 1701 |
Subject: | SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrect |
DataStreams: | sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
Description: | Soil heat flow #3 was large negative during the indicated period. |
Measurements: | sgp15ebbrE25.a1:
sgp30ebbrE25.b1:
sgp15ebbrE25.b1:
sgp30ebbrE25.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/13/2001 | 0030 | 05/16/2001 | 1931 |
Subject: | SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrect |
DataStreams: | sgp15ebbrE25.a1, sgp15ebbrE25.b1, sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
Description: | Soil heat flow #1 was large negative or large positive during the indicated period. |
Measurements: | sgp15ebbrE25.a1:
sgp30ebbrE25.b1:
sgp15ebbrE25.b1:
sgp30ebbrE25.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/02/2002 | 1500 | 05/02/2002 | 1531 |
Subject: | SGP/EBBR/E26 - 6 Month Checks |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/15/2002 | 2215 | 04/08/2002 | 1431 |
Subject: | SGP/EBBR/E25 - Reprocess: Soil Heat Flow #5 Negative Offset |
DataStreams: | sgp30ebbrE25.a1, sgp30ebbrE25.b1 |
Description: | Soil heat flow 5 was either too large negative or negative when it should have been positive; the cause of the negative offset is unknown, but is often the result of a failed J-panel over-voltage protection device. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g2 + g3 + g4)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE25.b1:
sgp30ebbrE25.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/2002 | 1500 | 05/30/2002 | 1501 |
Subject: | SGP/EBBR/E26 - Measurements Zero |
DataStreams: | sgp5ebbrE26.00, sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The measurements are often zero after a CR10 datalogger restart, as occurred here. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp5ebbrE26.00:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/2002 | 1530 | 05/30/2002 | 1531 |
Subject: | SGP/EBBR/E26 - Measurements Incorrect |
DataStreams: | sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Change of energy storage (CES) measurements (calculated from the change of soil temperature with time) are sometimes incorrect after a CR10 program restart because the beginning measurement of the averaging period is zero. Average soil heat flow, sensible heat flux, and latent heat flux were affected and cannot be recalculated. |
Measurements: | sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/01/2002 | 2115 | 06/30/2002 | 2356 |
Subject: | SGP/EBBR/E26 - Multiplexer 2 Failure From High Temperature |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Multiplexer 2 is failing during times of control box temperatures above 29 degrees C. The failure begins in the last channel and progresses to lower channels as the temperature increases. It has not yet been determined whether the failure is in the relays or a solid state component of the multiplexer. This condition is probably due to the aging of the device and the millions of cycles that this 10 year old device has made. More failures of this sort may occur in the future. A cure is being sought aside from replacement of the multiplexers to prevent the problem. The indicated measurements need to be inspected to determine which ones are usable. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE2.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30ebbrE8.b1:
sgp30ebbrE4.b1:
sgp30ebbrE9.b1:
sgp30ebbrE18.b1:
sgp30ebbrE26.b1:
sgp30ebbrE13.b1:
sgp30ebbrE7.b1:
sgp30ebbrE12.b1:
sgp30ebbrE19.b1:
sgp30ebbrE2.b1:
sgp30ebbrE22.b1:
sgp30ebbrE20.b1:
sgp30ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/27/2002 | 1605 | 11/27/2002 | 1635 |
Subject: | SGP/EBBR/E26 - Data Incorrect during 6 month checks |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2002 | 1600 | 07/11/2002 | 1629 |
Subject: | SGP/EBBR/E26 - Measurements zero following logger restart |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2002 | 0000 | 07/11/2002 | 1300 |
Subject: | SGP/EBBR/E26 - Multiplexer Problem |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | One of the multiplexers exhibited dropouts of the channels, beginning with the last channel at temperatures above about 30 C and moving backward through the channels as the temperature rose. High temperatures affected the switching speed of the multiplexer. This is the first time that this behavior has been documented in a Campbell Scientific multiplexer. The multiplexer had been in continuous field use for 10 years and had experienced probably more switching cycles than what is normally expected of the device in that period. The multiplexer was replaced to solve the problem. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/27/2002 | 0830 | 09/05/2002 | 1700 |
Subject: | SGP/EBBR/E26 - Water in broken Net Radiometer Dome |
DataStreams: | sgp5ebbrE26.a1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The net radiation measurement is incorrect. Measurements calculated using net radiation are also incorrect. No work-around is possible for this situation. |
Measurements: | sgp5ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2002 | 0845 | 11/06/2002 | 0130 |
Subject: | SGP/EBBR/E26 - Battery Voltage Low |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | When Battery Voltage drops below 10.5 volts, most measurements are suspect and some are often incorrect. The user will need to inspect the data carefully to determine the useability of the data. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/04/2002 | 1015 | 01/10/2003 | 1600 |
Subject: | SGP/EBBR/E26 - AEM Hung |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The AEM hung inbetween home positions during the period. The Bowen ratio, gradient measurements, sensible heat flux, and latent heat flux are incorrect. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/10/2003 | 1900 | 01/10/2003 | 1904 |
Subject: | SGP/EBBR/E26 - Data zeros following logger restart |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Most measurements were zero after restart of the CR10 datalogger, after a calibration changeout of the EBBR unit. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/14/2003 | 1725 | 01/23/2003 | 1715 |
Subject: | SGP/EBBR/E26 - Left Air Temperature Incorrect |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The left air temperature was incorrect during the period. Poor electronic connections may have caused this. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/19/2003 | 1900 | 05/16/2003 | 1500 |
Subject: | SGP/EBBR/E26 - E26 EBBR Soil Heat Flow #1 Incorrect |
DataStreams: | sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Soil Heat Flow #1 was incorrect much of the time. The sensor was replaced. |
Measurements: | sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2003 | 1030 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR/E27 - E27 EBBR Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) |
DataStreams: | sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30ebbrE27.a1:
sgp30ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 04/08/2002 | 2359 |
Subject: | SGP/EBBR/E25 - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE25.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30ebbrE25.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2003 | 1030 | 07/09/2003 | 1700 |
Subject: | SGP/EBBR/E27 - Soil Heat Flow #2 Incorrect |
DataStreams: | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | Soil Heat Flow sensor #2 was intermittently incorrect at first and then constantly so later in the period. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/15/2003 | 0100 | 06/23/2003 | 1900 |
06/27/2003 | 1030 | 06/27/2003 | 1300 |
06/30/2003 | 0030 | 06/30/2003 | 0730 |
06/30/2003 | 1000 | 06/30/2003 | 2000 |
07/05/2003 | 0400 | 07/10/2003 | 0500 |
07/10/2003 | 1430 | 07/20/2003 | 0300 |
07/20/2003 | 1730 | 07/21/2003 | 0230 |
07/21/2003 | 1930 | 07/22/2003 | 0230 |
07/22/2003 | 1730 | 07/23/2003 | 0600 |
07/23/2003 | 1630 | 07/23/2003 | 1900 |
Subject: | SGP/EBBR/E27 - Soil Heat Flow #4 Incorrect |
DataStreams: | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | Soil Heat flow sensor #4 outputs were often very small negative numbers. See below for a work-around. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2003 | 1030 | 05/15/2003 | 1600 |
05/18/2003 | 1800 | 05/28/2003 | 1700 |
Subject: | SGP/EBBR/E27 - Reference T Sensor Failure |
DataStreams: | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | The reference T sensor was not working much of the time, affecting all other temperature sensors. Sensible and latent heat fluxes were incorrect when this occurred. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp5ebbrE27.a1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2003 | 1030 | 06/12/2003 | 1800 |
Subject: | SGP/EBBR/E27 - Wind Direction Hung |
DataStreams: | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | The Wind Direction frequently hung at values in the 70s or 80s. No other data was affected. Fluxes were not affected. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp5ebbrE27.a1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/24/2003 | 1635 | 03/06/2003 | 1520 |
Subject: | SGP/EBBR/E26 -Right Air Temperature Incorrect |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | One of the Right Air Temperature connections was loose, producing incorrect data. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/17/2003 | 1445 | 04/17/2003 | 1535 |
Subject: | SGP/EBBR/E26 - 6 Month Checks |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/15/2003 | 1600 | 05/15/2003 | 1645 |
Subject: | SGP/EBBR/E27 - 6 Month Checks |
DataStreams: | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp5ebbrE27.a1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/12/2003 | 0230 | 06/12/2003 | 0300 |
06/13/2003 | 1200 | 06/13/2003 | 1230 |
Subject: | SGP/EBBR/E26 - Soil Heat Flow #5 Large Positive |
DataStreams: | sgp15ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | Soil Heat Flow #5 was large positive for these two periods, for an unknown reason. |
Measurements: | sgp15ebbrE26.b1:
sgp15ebbrE26.a1:
sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/25/2003 | 1630 | 06/25/2003 | 1630 |
Subject: | SGP/EBBR/E27 - Soil Heat Flow #1 Large |
DataStreams: | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | Soil Heat Flow #1 was large for this period, for an unknown reason. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/09/2003 | 1700 | 07/09/2003 | 1700 |
Subject: | SGP/EBBR/E27 - Incorrect Data From Logger Restart |
DataStreams: | sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | Some 30 minute was zero or incorrect after restart of the CR10. This is a common occurrence when sensor replacements are made or power outages occur. |
Measurements: | sgp30ebbrE27.a1:
sgp30ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/21/2003 | 1600 | 08/21/2003 | 1600 |
Subject: | SGP/EBBR/E26 - Soil Storage Incorrect; Surface Fluxes Incorrect |
DataStreams: | sgp30ebbrE26.a1, sgp30ebbrE26.b1 |
Description: | The half hour after restart of the CR10 datalogger, the soil temperatures for the beginning of the period are missing. Therefore the soil energy storage and surface flux values are also incorrect. |
Measurements: | sgp30ebbrE26.b1:
sgp30ebbrE26.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/30/2003 | 0630 | 09/03/2003 | 1700 |
Subject: | SGP/EBBR/E27 - Water in Net Radiometer; Surface Fluxes are Incorrect |
DataStreams: | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp5ebbrE27.a1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/20/2003 | 1600 | 08/20/2003 | 1600 |
Subject: | SGP/EBBR/E27 - 15 and 30 Minute Data All Zeros |
DataStreams: | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | 15 and 30 minute measurements were all zero after restarting the CR10 datalogger. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 1030 | 11/17/2003 | 0630 |
Subject: | SGP/EBBR/E27 - Right Air Temperature Spiked Offscale |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The right air temperature was going offscale at times. This problem seemed to end without Site Ops. intervention. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/29/2003 | 1700 | 10/29/2003 | 1930 |
Subject: | SGP/EBBR/E27 - Missing data during system update |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | Some soil parameters were slightly incorrect since EBBR.E27 was installed in May 2003. While the coefficients were being updated, data collection was suspended resulting in missing data for the specified period. No significant effects (1% or less) on the surface heat flux data would have occurred from using the slightly incorrect coefficients. Therefore, flagging of the surface flux data from the time of installation of E27 is unwarranted. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/30/2003 | 1545 | 11/13/2003 | 1545 |
Subject: | SGP/EBBR/E26 - AEM Home Signals Incorrect, Surface Fluxes Incorrect |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | During a preventative maintenance visit to perform the 6-month calibrations, the home15 and home30 outputs began reading the same as one another. A fuse replacement and lubrication of the AEM sprockets on 11/13 corrected the problem. During the interval specified, the home15, home30, and sensible and latent heat fluxes are incorrect. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/06/2003 | 1200 | 10/11/2003 | 0730 |
Subject: | SGP/EBBR/E27 - Right Air Temperature Spiked Offscale |
DataStreams: | sgp5ebbrE27.a1, sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | The right air temperature was going offscale at times. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp5ebbrE27.a1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/30/2003 | 1535 | 10/30/2003 | 1615 |
Subject: | SGP/EBBR/E26 - 6 Month Checks |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/29/2003 | 1830 | 10/29/2003 | 1945 |
Subject: | SGP/EBBR/E27 - 6 Month Checks |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/12/2003 | 1700 | 10/12/2003 | 2359 |
Subject: | SGP/EBBR/E27 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect |
DataStreams: | sgp15ebbrE27.a1, sgp15ebbrE27.b1, sgp30ebbrE27.a1, sgp30ebbrE27.b1 |
Description: | Soil Heat Flow #5 went offscale at times. Latent and Sensible Heat Fluxes were incorrect when this occurred. |
Measurements: | sgp30ebbrE27.a1:
sgp15ebbrE27.a1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 09/29/2004 | 1845 |
Subject: | SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | In a trip to E26, I found that a bad spark gap through which the barometer was powered was causing pressure measurements to be incorrect. The pressure readings oscillated with the voltage of the EBBR battery. During daytime the voltage and thus the pressure would increase and vice versa during dark hours. Apparently only the positive side of the power supply was properly connected through the spark gap and thus the voltage received by the pressure sensor was lower than required to power it properly. Under this condition the perssure measurement varies with voltage level. The pressure measurements therefore had a diurnal signature and usually were incorrect. The decreased pressure during most times would cause latent heat flux to be slightly overestimated and sensible heat flux to be slightly underestimated. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2003 | 1935 | 12/14/2003 | 1615 |
Subject: | SGP/EBBR/E26 - Wind Speed Sensor Frozen By Ice Storm |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | The wind speed sensor was frozen stopped by ice from a storm. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2003 | 2140 | 12/14/2003 | 1530 |
Subject: | SGP/EBBR/E26 - Wind Direction Sensor Frozen By Ice Storm |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/06/2003 | 0900 | 12/06/2003 | 0900 |
Subject: | SGP/EBBR/E27 - Soil Temperature #3 Spike in Data |
DataStreams: | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The soil temperature #3 spiked to zero and was therefore incorrect. |
Measurements: | sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0705 | 02/02/2004 | 1800 |
02/05/2004 | 0205 | 02/05/2004 | 0600 |
Subject: | SGP/EBBR/E27 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0200 | 02/02/2004 | 1620 |
Subject: | SGP/EBBR/E26 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0410 | 02/02/2004 | 1530 |
Subject: | SGP/EBBR/E26 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp5ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/25/2004 | 0600 | 05/12/2004 | 1930 |
Subject: | SGP/EBBR/E27 - Soil Moisture #5 Insensitive |
DataStreams: | sgp30ebbrE27.b1 |
Description: | Soil moisture sensor #5 was insensitive and put out a value of around 30%. Sensible and latent heat fluxes were not significantly affected by this small error. |
Measurements: | sgp30ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2004 | 0000 | 03/31/2004 | 2355 |
Subject: | SGP/EBBR/E27 - Right Air Temperature Incorrect |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The right air temperature, and therefore top and bottom air temperatures were offscale or incorrect on occasion. Bowen ratio, sensible heat flux, and latent heat flux were also incorrect during those times. Inspection of the data is required to detect the incorrect periods. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/10/2004 | 0600 | 07/21/2004 | 1725 |
Subject: | SGP/EBBR/E27 - Loose Tair Left Connections |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | Tair left dropped out at times. When this occurred, the sensible and latent heat fluxes are incorrect. Tightening of the electronic connections to the datalogging equipment appears to have solved the problem. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/21/2004 | 1700 | 07/21/2004 | 1900 |
Subject: | SGP/EBBR/E27 - Data Missing or Incorrect During Battery Terminal Cleaning |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The data is missing or incorrect during this period while the battery terminals were being cleaned. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/30/2004 | 1600 | 08/05/2004 | 1530 |
Subject: | SGP/EBBR/E26 - Soil Temperature #4 and Soil Heat Flow #4 Incorrect |
DataStreams: | sgp30ebbrE26.b1 |
Description: | The soil temperature and soil heat flow probes for set #4 was pulled partially out of the ground. This caused soil temperature #4 to be too high and soil heat flow #4 to be too low. The error is not so great as to cause a large error in the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/21/2003 | 1530 | 10/12/2003 | 2355 |
Subject: | SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect |
DataStreams: | sgp5ebbrE26.a1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | In a trip to E26, I found that a bad spark gap through which the barometer was powered was causing pressure measurements to be incorrect. The pressure readings oscillated with the voltage of the EBBR battery. During daytime the voltage and thus the pressure would increase and vice versa during dark hours. Apparently only the positive side of the power supply was properly connected through the spark gap and thus the voltage received by the pressure sensor was lower than required to power it properly. Under this condition the perssure measurement varies with voltage level. The pressure measurements therefore had a diurnal signature and usually were incorrect. The decreased pressure during most times would cause latent heat flux to be slightly overestimated and sensible heat flux to be slightly underestimated. |
Measurements: | sgp5ebbrE26.a1:
sgp15ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/30/2004 | 1530 | 09/30/2004 | 1600 |
Subject: | SGP/EBBR/E26 - 6 Month Checks |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2004 | 2000 | 09/29/2004 | 2030 |
Subject: | SGP/EBBR/E27 - 6 Month Checks |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/27/2004 | 1930 | 11/05/2004 | 0100 |
11/10/2004 | 0600 | 11/24/2004 | 1500 |
Subject: | SGP/EBBR/E26 - Low Battery Voltage - Many Measurements Incorrect |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | During low battery voltage conditions (< 10.5 V especially) many measurements are incorrect. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/29/2004 | 1100 | 10/29/2004 | 1600 |
Subject: | SGP/EBBR/E26 - Most Measurements Incorrect |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | Most of the measurements became either too large or too small. The cause is not known. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 0745 | 01/07/2005 | 1530 |
Subject: | SGP/EBBR/E26 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1555 | 01/07/2005 | 1605 |
Subject: | SGP/EBBR/E27 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1020 | 01/06/2005 | 1730 |
Subject: | SGP/EBBR/E26 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/06/2005 | 1005 | 01/07/2005 | 1430 |
Subject: | SGP/EBBR/E27 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2004 | 1400 | 02/17/2005 | 1630 |
Subject: | SGP/EBBR/E26 - Aging Pressure Sensor Output Changes With Supply Voltage |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | The E26 EBBR pressure sensor experienced the poor internal voltage regulation problem experienced at other sites last year. Aging of the internal voltage regulator caused the pressure output to drop by 1-2 kPa (0.1-0.5 kPa is normal) when the Sun rose and the solar panel goosed the battery voltage up. The sensible and latent heat fluxes were not significantly affected. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/15/2004 | 1600 | 03/07/2005 | 2100 |
Subject: | SGP/EBBR/E27 - Soil Moisture #5 Incorrect |
DataStreams: | sgp30ebbrE27.b1 |
Description: | The wrong CR10 program loaded from the storage module on 9/15/04. During the previous change of program, an attempt was made to store the new program in the storage module; site ops techs did not notice that this attempt failed, leaving the old program in the storage module. When power was cyled on 9/15/04, the old program with flat sm5 coefficients loaded into the CR10. The "flat" coefficients resulted in the sm5 soil moisture hovering around 30%. 15 minute raw sm5 resistances were correct. Average soil heat flow, sensible heat flux, and latent heat flux were not significantly affected and so are not included in the list of incorrect measurements. |
Measurements: | sgp30ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/10/2003 | 1700 | 03/03/2005 | 1600 |
Subject: | SGP/EBBR/E26 - Incorrect soil type coefficients used |
DataStreams: | sgp30ebbrE26.b1 |
Description: | The soil type coefficents for soil moisture were incorrect from the day of the system installation on, making soil moisture values too large. As a result, soil heat flows were overmeasured, and sensible and latent heat fluxes were underestimated. |
Measurements: | sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/04/2004 | 1645 | 03/02/2005 | 1600 |
Subject: | SGP/EBBR/E27 - SM2 Coefficients Incorect |
DataStreams: | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | Soil Moisture #2 coefficients in the CR10 datalogger program were incorrect during the time that an old program version was installed. |
Measurements: | sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/31/2005 | 1700 |
Subject: | SGP/EBBR/E26 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE26.b1 |
Description: | Effective 20050331.1700, the EBBR.E26 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050331, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE26.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE26.a1). ~ |
Measurements: | sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2003 | 0000 | 03/30/2005 | 1730 |
Subject: | SGP/EBBR/E27 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE27.b1 |
Description: | Effective 20050330.1730, the EBBR.E27 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050330, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE27.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE27.a1). |
Measurements: | sgp30ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/20/2005 | 1200 | 08/21/2005 | 1900 |
09/29/2005 | 1430 | 09/29/2005 | 1900 |
Subject: | SGP/EBBR/E26 - All E26 EBBR Data Missing |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | All E26 EBBR data was missing during these periods. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2005 | 2200 | 08/17/2005 | 1600 |
Subject: | SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The net radiometer top dome was broken and water got inside, making the net radiation, and sensible and latent heat flux measurements incorrect. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/17/2005 | 1630 | 08/27/2005 | 1930 |
Subject: | SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredt |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | Residual Moisture left in the top dome of the net radiometer after the 8/17/05 servicing caused the net radiation measurements to be biased low, and resulting in sensible and latent heat flux being low also. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/15/2005 | 1800 | 09/21/2005 | 0300 |
Subject: | SGP/EBBR/E27 - All E27 EBBR Data is Missing |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | All E27 EBBR data was missing from this period. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/03/2005 | 1800 | 03/31/2005 | 1700 |
Subject: | SGP/EBBR/E26 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE26.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/02/2005 | 1600 | 03/30/2005 | 1730 |
Subject: | SGP/EBBR/E27 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE27.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 08/16/2005 | 2359 |
Subject: | SGP/EBBR/E27 - metadata corrections |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | On 20050816, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E27 data collected by ARM back to the installation of the instrument in May 2003. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp30ebbrE27.b1:
sgp5ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E26 - metadata corrections |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E26 data collected by ARM back to the installation of the instrument in June 1992. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 04/08/2002 | 2359 |
Subject: | SGP/EBBR/E25 - metadata errors |
DataStreams: | sgp15ebbrE25.b1, sgp30ebbrE25.b1 |
Description: | During the entire span of EBBR.E25 data, the cdf data files contained a few minor global metadata errors. These errors do not affect the data values or quality. The errors include: * incomplete sensor location information * incomplete installation date information * soil moisture documented as "by volume" should have read "gravimetric" |
Measurements: | sgp30ebbrE25.b1:
sgp15ebbrE25.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/20/2005 | 0800 | 12/22/2005 | 1500 |
Subject: | SGP/EBBR/E26 - Data Suspect During Low Supply Voltage |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | Low battery supply voltage resulted in high home signals and questionable data at times. Data for battery voltage <10.5 volts should be considered to be incorrect. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/03/2006 | 0000 | 05/10/2006 | 1130 |
05/25/2006 | 2100 | 06/20/2006 | 1730 |
Subject: | SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The left T/RH probe temperature sensor was spiking some of the time during these periods. Therefore, sensible and latent heat fluxes were incorrect during parts of the periods as well. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/21/2006 | 0400 | 02/25/2006 | 1700 |
Subject: | SGP/EBBR/E26 - Measurements Incorrect |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | Most measurements were incorrect during low battery voltage conditions. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/18/2006 | 0330 | 03/01/2006 | 1615 |
Subject: | SGP/EBBR/E27 - Flux and Gradient Measurements Incorrect |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The sensible and latent heat flux and gradient measurements were incorrect while the AEM was hung in one position. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/09/2006 | 1900 | 04/16/2006 | 1600 |
Subject: | SGP/EBBR/E27 - Instrument problem, Loose connections |
DataStreams: | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The soil heat flow #1 sensor went offscale low on occasion. This sometimes caused sensible and latent heat fluxes to be 9999ed out by the EBBR programming, but not always. |
Measurements: | sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2006 | 0130 | 07/21/2006 | 1730 |
Subject: | SGP/EBBR/E27 - Field fire burned AEM |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | A fire in the E27 field burned the AEM, making it non-functional. Sensible and latent heat fluxes and gradients were incorrect during this period. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/04/2006 | 1930 | 05/04/2006 | 2200 |
05/05/2006 | 0230 | 05/05/2006 | 0800 |
05/06/2006 | 0430 | 06/20/2006 | 1730 |
Subject: | SGP/EBBR/E27 - Sensible, Latent, and Average Soil Heat Fluxes Sometimes Incorrect |
DataStreams: | sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The Soil Heat Flow #1 sensor kept going offscale. Sensible and Latent heat fluxes and the ave_shf were affected and sometimes incorrect. |
Measurements: | sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/31/2006 | 0600 | 06/07/2006 | 1730 |
06/14/2006 | 0500 | 06/20/2006 | 1730 |
Subject: | SGP/EBBR/E27 - Low Battery Condition |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | A low battery condition caused most of the measurements to be incorrect. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/26/2006 | 1830 | 08/17/2006 | 1730 |
Subject: | SGP/EBBR/E27 - Most Measurements Suspect |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | The wrong EBBR program was used at this site. Therefore, most of the measurements are suspect. Note: Mentor reports reprocessing will not correct this problem. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/11/2006 | 1300 | 08/21/2006 | 2330 |
Subject: | SGP/EBBR/E27 - Battery Voltage Problem - Measurements Incorrect |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
Description: | Battery voltage was too low much of the time during the period, thus most measurements were incorrect during much of the time period. |
Measurements: | sgp5ebbrE27.b1:
sgp30ebbrE27.b1:
sgp15ebbrE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2006 | 1730 | 10/17/2006 | 0030 |
Subject: | SGP/EBBR/E26 - Missing Data |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | All data was missing during this period. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|