DQR ID | Subject | Data Streams Affected |
---|---|---|
D001121.14 | SGP/NIMFR/E13 - Low calibration | sgpnimfrE13.a1 |
D001121.5 | SGP/NIMFR/E13 - Low calibration | sgpnimfrE13.a1 |
D001129.13 | SGP/NIMFR/E13 - Low calibration | sgpnimfrE13.a1 |
D001129.8 | SGP/NIMFR/E13 - Low calibration | sgpnimfrE13.a1 |
D010109.6 | SGP/NIMFR/E13 - Calibration too low | sgpnimfrE13.a1 |
D020827.2 | SGP/NIMFR/E13 - Centrovision filter leakage | sgpnimfrE13.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/2000 | 0000 | 10/31/2000 | 2359 |
Subject: | SGP/NIMFR/E13 - Low calibration |
DataStreams: | sgpnimfrE13.a1 |
Description: | New instrument being tested, calibration too low - per Jim Barnard. |
Measurements: | sgpnimfrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/01/2000 | 0000 | 08/31/2000 | 2359 |
Subject: | SGP/NIMFR/E13 - Low calibration |
DataStreams: | sgpnimfrE13.a1 |
Description: | New instrument being tested, calibration too low - per Jim Barnard. |
Measurements: | sgpnimfrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/17/2000 | 0000 | 09/30/2000 | 2359 |
Subject: | SGP/NIMFR/E13 - Low calibration |
DataStreams: | sgpnimfrE13.a1 |
Description: | New instrument being tested, calibration too low, per Jim Barnard. |
Measurements: | sgpnimfrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/01/2000 | 0000 | 09/07/2000 | 2359 |
Subject: | SGP/NIMFR/E13 - Low calibration |
DataStreams: | sgpnimfrE13.a1 |
Description: | New instrument being tested, calibration too low, per Jim Barnard. |
Measurements: | sgpnimfrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2000 | 0000 | 11/30/2000 | 2359 |
Subject: | SGP/NIMFR/E13 - Calibration too low |
DataStreams: | sgpnimfrE13.a1 |
Description: | New instrument being tested, calibration too low (to be updated soon), per Ron Severtsen. |
Measurements: | sgpnimfrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/17/2000 | 0101 | 11/29/2001 | 2359 |
Subject: | SGP/NIMFR/E13 - Centrovision filter leakage |
DataStreams: | sgpnimfrE13.a1 |
Description: | Testing of the batch of centrovision filters being used in the NIMFR EF13 instrument indicate that the first four filters leak 'out of band' light. The leakage for each filter is (1)415nm 3%, (2)500nm 1-2%, (3)615nm 1-2%, (4)673nm 3%. Acceptable leakage is less than 0.5%. This leakage causes an error in the irradiance values (too high) at these four wavelengths and the optical depths calculated using this data will be too high |
Measurements: | sgpnimfrE13.a1:
|