Data Quality Reports for Session: 106121 User: lepagano Completed: 06/18/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060622.1SGP/EBBR/E13 - Left Air Temperature Incorrect - Fluxes Affectedsgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1
D060622.2SGP/EBBR/E13 - Fluxes Incorrect, AEM Problemssgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1


DQRID : D060622.1
Start DateStart TimeEnd DateEnd Time
04/23/2006230004/23/20062300
06/03/2006190006/04/20062330
Subject:
SGP/EBBR/E13 - Left Air Temperature Incorrect - Fluxes Affected
DataStreams:sgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1
Description:
The left air temperature was incorrect, thus the Bowen ratio and sensible and latent heat 
fluxes were incorrect also.
Measurements:sgp15ebbrE13.b1:
  • Left air temperature(tair_l)

sgp5ebbrE13.b1:
  • bottom air temperature(tair_bot)
  • top air temperature(tair_top)

sgp30ebbrE13.b1:
  • bottom air temperature(tair_bot)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • latent heat flux(e)
  • corrected sensible heat flux(h)


Back To Table of Contents

DQRID : D060622.2
Start DateStart TimeEnd DateEnd Time
04/30/2006210005/01/20061530
06/05/2006233006/06/20061600
06/14/2006203006/15/20061430
Subject:
SGP/EBBR/E13 - Fluxes Incorrect, AEM Problems
DataStreams:sgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1
Description:
The AEM did not function properly, thus sensible and latent heat fluxes were incorrect.
Measurements:sgp15ebbrE13.b1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp5ebbrE13.b1:
  • temperature of the bottom humidity sensor chamber(thum_bot)
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • temperature of the top humidity sensor chamber(thum_top)
  • bottom vapor pressure(vp_bot)
  • bottom relative humidity(hum_bot)
  • top relative humidity(hum_top)
  • bottom air temperature(tair_bot)

sgp30ebbrE13.b1:
  • bottom relative humidity(hum_bot)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • temperature of the bottom humidity sensor chamber(thum_bot)
  • temperature of the top humidity sensor chamber(thum_top)
  • latent heat flux(e)
  • corrected sensible heat flux(h)
  • bottom air temperature(tair_bot)
  • top air temperature(tair_top)
  • top relative humidity(hum_top)
  • top vapor pressure(vp_top)


Back To Table of Contents



END OF DATA