Data Quality Reports for Session: 108672 User: mackaro Completed: 10/30/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D070917.1SGP/EBBR/E13 - Radiometer dome brokensgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1


DQRID : D070917.1
Start DateStart TimeEnd DateEnd Time
09/02/2006040009/14/20061900
Subject:
SGP/EBBR/E13 - Radiometer dome broken
DataStreams:sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1
Description:
The top net radiometer dome was broken, yielding net radiation, sensible heat flux and 
latent heat flux that were too low.

The BEFLUX (SIRS) net radiation can be used as a replacement for the EBBR net radiation.

To correct the sensible and latent heat fluxes, determine the ratio of SIRS net radiation 
to EBBR net radiation for each daylight half hour and multiply that ratio times H and LE 
to obtain approximate corrected flux values.
Measurements:sgp15ebbrE13.b1:
  • Net radiation(mv_q)

sgp5ebbrE13.b1:
  • net radiation(q)

sgp30ebbrE13.b1:
  • net radiation(q)
  • latent heat flux(e)
  • h(h)


Back To Table of Contents