Data Quality Reports for Session: 108711 User: moore Completed: 11/01/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060426.8TWP/SMET/C3 - ORG data noisy due to degraded groundtwpsmet60sC3.b1
D060522.1TWP/SMET/C1 - Upper wind speed sensor failuretwpsmet60sC1.b1
D060614.2TWP/SMET/C2 - Temp/RH probe failuretwpsmet60sC2.b1
D060627.1TWP/SMET/C3 - Anemometer Readings Incorrecttwpsmet60sC3.b1
D060817.3TWP/SMET/C1 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC1.b1
D060818.2TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC2.b1
D060818.3TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC3.b1
D061011.2TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC1.b1
D061011.3TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC2.b1
D061011.4TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC3.b1
D070306.2TWP/SMET/C3 - Barometer Data Incorrecttwpsmet60sC3.b1
D070306.3TWP/SMET/C3 - Data Incorrect Due to Water Intrusiontwpsmet60sC3.b1
D070409.1TWP/SMET/C1 - Upper winds failuretwpsmet60sC1.b1
D070510.5TWP/SMET/C2 - Lower windspeed sensor questionabletwpsmet60sC2.b1
D070803.1TWP/SMET/C3 - Upper wind speed artificially slowtwpsmet60sC3.b1


DQRID : D060426.8
Start DateStart TimeEnd DateEnd Time
12/01/2005000008/24/20062359
Subject:
TWP/SMET/C3 - ORG data noisy due to degraded ground
DataStreams:twpsmet60sC3.b1
Description:
SMET Rain Data began to be noisy during December 2005 and the problem slowly became worse 
over time so that in February 2006 the ORG was reporting with a constant background value 
of around 0.10 mm/hr rain rate.  ORG voltage showed a near constant value above the 85mV 
threshold.  The ground for the ORG had become degraded and was lost due to corrosion.
Measurements:twpsmet60sC3.b1:
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • Precipitation standard deviation(precip_sd)
  • precipitation minimum(precip_min)


Back To Table of Contents

DQRID : D060522.1
Start DateStart TimeEnd DateEnd Time
05/09/2006000010/14/20060237
Subject:
TWP/SMET/C1 - Upper wind speed sensor failure
DataStreams:twpsmet60sC1.b1
Description:
The upper wind speed sensor was binding at low wind speeds.  Comparison to the lower wind 
sensor showed that the upper sensor flat-lines for long periods of time.  The upper 
anemometer was replaced.
Measurements:twpsmet60sC1.b1:
  • Wind #1 speed standard deviation(wind1_spd_sd)
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Wind #1 direction standard deviation(wind1_dir_sd)
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • Wind #1 speed maximum(wind1_spd_max)
  • Wind #1 direction vector average(wind1_dir_vec_avg)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Wind #1 speed minimum(wind1_spd_min)


Back To Table of Contents

DQRID : D060614.2
Start DateStart TimeEnd DateEnd Time
06/05/2006214406/15/20060427
Subject:
TWP/SMET/C2 - Temp/RH probe failure
DataStreams:twpsmet60sC2.b1
Description:
Temperature/RH probe failed and was replaced.
Measurements:twpsmet60sC2.b1:
  • Mean Relative Humidity(relh_mean)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Relative humidity maximum(relh_max)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • Std Dev of Air Temperature(temp_sd)
  • Temperature minimum(temp_min)
  • Relative humidity minimum(relh_min)
  • Vapor pressure standard deviation(vappress_sd)
  • Temperature maximum(temp_max)
  • Vapor pressure mean(vappress_mean)


Back To Table of Contents

DQRID : D060627.1
Start DateStart TimeEnd DateEnd Time
06/27/2006011506/27/20060344
Subject:
TWP/SMET/C3 - Anemometer Readings Incorrect
DataStreams:twpsmet60sC3.b1
Description:
The Anemometer readings were incorrect due to the tower being lowered for maintenance.
Measurements:twpsmet60sC3.b1:
  • Wind #2 speed arithmetic average(wind2_spd_arith_avg)
  • Wind #1 speed minimum(wind1_spd_min)
  • Wind #1 direction vector average(wind1_dir_vec_avg)
  • Wind #1 speed standard deviation(wind1_spd_sd)
  • Wind #2 speed maximum(wind2_spd_max)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Wind #2 direction vector average(wind2_dir_vec_avg)
  • Wind #1 direction standard deviation(wind1_dir_sd)
  • Wind #2 speed vector average(wind2_spd_vec_avg)
  • Wind #2 speed maximum gust(wind2_spd_max_gust)
  • Wind #1 speed maximum(wind1_spd_max)
  • Wind #2 speed minimum(wind2_spd_min)
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • Wind #2 direction standard deviation(wind2_dir_sd)
  • Wind #2 speed standard deviation(wind2_spd_sd)


Back To Table of Contents

DQRID : D060817.3
Start DateStart TimeEnd DateEnd Time
10/09/1996000007/13/20062225
Subject:
TWP/SMET/C1 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC1.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC1.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D060818.2
Start DateStart TimeEnd DateEnd Time
10/21/1998000007/13/20062232
Subject:
TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC2.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D060818.3
Start DateStart TimeEnd DateEnd Time
12/02/2003000007/13/20062219
Subject:
TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC3.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.2
Start DateStart TimeEnd DateEnd Time
10/09/1996000010/17/20060000
Subject:
TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC1.b1
Description:
A tipping bucket rain gauge was added to the TWP.C1 SMET suite of instruments on 20061017. 
 Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC1.b1 datastream.  Between 9/26 and 10/17, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros 
are not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19961009-20060926 and data from 
19961009-20061017 will be filled with -9999 (missing).
Measurements:twpsmet60sC1.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D061011.3
Start DateStart TimeEnd DateEnd Time
10/21/1998000011/29/20062014
Subject:
TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC2.b1
Description:
A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. 
Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC2.b1 datastream.  Between 9/26 and 11/29, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros are 
not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19981021-20060926 and data from 
19981021-20061129 will be filled with -9999 (missing).
Measurements:twpsmet60sC2.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D061011.4
Start DateStart TimeEnd DateEnd Time
03/12/2002000009/26/20061435
Subject:
TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC3.b1
Description:
A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. 
 Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 
datastream.  When reprocessing of this datastream occurs these variables will be added 
with -9999 (missing) as the value for dates prior to gauge installation.
Measurements:twpsmet60sC3.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D070306.2
Start DateStart TimeEnd DateEnd Time
03/02/2007172303/03/20071228
Subject:
TWP/SMET/C3 - Barometer Data Incorrect
DataStreams:twpsmet60sC3.b1
Description:
The barometer data was incorrect or missing due to water intrusion.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D070306.3
Start DateStart TimeEnd DateEnd Time
03/03/2007005603/03/20070123
Subject:
TWP/SMET/C3 - Data Incorrect Due to Water Intrusion
DataStreams:twpsmet60sC3.b1
Description:
Data became erratic and unreasonable after water intrusion into the enclosure.
Measurements:twpsmet60sC3.b1:
  • Vapor pressure standard deviation(vappress_sd)
  • Precipitation maximum(precip_max)
  • Relative humidity maximum(relh_max)
  • Mean Relative Humidity(relh_mean)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • Relative humidity minimum(relh_min)
  • precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • Temperature minimum(temp_min)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Temperature maximum(temp_max)
  • Precipitation standard deviation(precip_sd)
  • Vapor pressure mean(vappress_mean)
  • Std Dev of Air Temperature(temp_sd)


Back To Table of Contents

DQRID : D070409.1
Start DateStart TimeEnd DateEnd Time
03/19/2007000006/12/20070406
Subject:
TWP/SMET/C1 - Upper winds failure
DataStreams:twpsmet60sC1.b1
Description:
The upper wind instrument was inoperative resulting in constant wind direction and speed.  
A failed cable was replaced.
Measurements:twpsmet60sC1.b1:
  • Wind #1 speed standard deviation(wind1_spd_sd)
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Wind #1 direction standard deviation(wind1_dir_sd)
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • Wind #1 speed maximum(wind1_spd_max)
  • Wind #1 direction vector average(wind1_dir_vec_avg)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Wind #1 speed minimum(wind1_spd_min)


Back To Table of Contents

DQRID : D070510.5
Start DateStart TimeEnd DateEnd Time
04/05/2007000008/19/20072135
Subject:
TWP/SMET/C2 - Lower windspeed sensor questionable
DataStreams:twpsmet60sC2.b1
Description:
Lower wind speed sensor had degraded bearings.  This sensor was reporting as much as 0.4 
m/s lower values than the upper sensors when the winds were 2 m/s or below.  The sensor 
was replaced.
Measurements:twpsmet60sC2.b1:
  • Wind #2 speed maximum(wind2_spd_max)
  • Wind #2 speed vector average(wind2_spd_vec_avg)
  • Wind #2 speed maximum gust(wind2_spd_max_gust)
  • Wind #2 speed standard deviation(wind2_spd_sd)
  • Wind #2 speed arithmetic average(wind2_spd_arith_avg)
  • Wind #2 speed minimum(wind2_spd_min)


Back To Table of Contents

DQRID : D070803.1
Start DateStart TimeEnd DateEnd Time
07/01/2007000009/18/20072315
Subject:
TWP/SMET/C3 - Upper wind speed artificially slow
DataStreams:twpsmet60sC3.b1
Description:
The upper wind measurement was consistently slower by around 0.5 - 1 m/s than the lower 
wind measurement.  The bearings on the upper wind measurement were binding.
Measurements:twpsmet60sC3.b1:
  • Wind #1 speed minimum(wind1_spd_min)
  • Wind #1 speed maximum(wind1_spd_max)
  • Wind #1 speed standard deviation(wind1_spd_sd)
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Wind #1 speed vector average(wind1_spd_vec_avg)


Back To Table of Contents



END OF DATA