Data Quality Reports for Session: 108946 User: gaustad Completed: 11/16/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D041117.1SGP/MWR/E14 - Reprocess: wrong retrievalssgpmwrlosE14.a1, sgpmwrlosE14.b1, sgpmwrtipE14.a1, sgpqmemwrcolE14.c1
D050725.6SGP/MWR/E14 - Reprocess: Revised Retrieval CoefficientssgpmwrlosE14.a1, sgpmwrlosE14.b1, sgpmwrtipE14.a1, sgpqmemwrcolE14.c1
D051011.3SGP/MWR/E14 - New software version (4.15) installedsgpmwrlosE14.b1, sgpmwrtipE14.a1


DQRID : D041117.1
Start DateStart TimeEnd DateEnd Time
06/24/2004194511/11/20042000
Subject:
SGP/MWR/E14 - Reprocess: wrong retrievals
DataStreams:sgpmwrlosE14.a1, sgpmwrlosE14.b1, sgpmwrtipE14.a1, sgpqmemwrcolE14.c1
Description:
When MWR#04 was installed at EF14 (replacing MWR#33), out-of-date retrieval coefficients 
were used in the configuration file.
The correct coefficients were applied when the computer, software, and configuration file 
were upgraded.
Measurements:sgpmwrlosE14.a1:
  • MWR column precipitable water vapor(vap)
  • Averaged total liquid water along LOS path(liq)

sgpmwrtipE14.a1:
  • Total liquid water along zenith path using tip-derived brightness temperatures(liqtip)
  • Total water vapor along zenith path using tip-derived brightness temperatures(vaptip)

sgpmwrlosE14.b1:
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)

sgpqmemwrcolE14.c1:
  • Ensemble average for MWR vapor in window centered about balloon release(mean_vap_mwr)
  • Ensemble average for MWR liquid in window centered about balloon release(mean_liq_mwr)


Back To Table of Contents

DQRID : D050725.6
Start DateStart TimeEnd DateEnd Time
04/16/2002000006/28/20052300
Subject:
SGP/MWR/E14 - Reprocess: Revised Retrieval Coefficients
DataStreams:sgpmwrlosE14.a1, sgpmwrlosE14.b1, sgpmwrtipE14.a1, sgpqmemwrcolE14.c1
Description:
IN THE BEGINNING (June 1992), the retrieval coefficients used to derive 
the precipitable water vapor (PWV) and liquid water path (LWP) from the 
MWR brightness temperatures were based on the Liebe and Layton (1987) 
water vapor and oxygen absorption model and the Grant (1957) liquid 
water absorption model.

Following the SHEBA experience, revised retrievals based on the more 
recent Rosenkranz (1998) water vapor and oxygen absorption models and 
the Liebe (1991) liquid waer absorption model were developed.  The 
Rosenkranz water vapor absorption model resulted a 2 percent increase 
in PWV relative to the earlier Liebe and Layton model.  The Liebe 
liquid water absorption model decreased the LWP by 10% relative to the 
Grant model.  However, the increased oxygen absorption caused a 
0.02-0.03 mm (20-30 g/m2) reduction in LWP, which was particularly 
significant for low LWP conditions (i.e. thin clouds encountered at 
SHEBA).

Recently, it has been shown (Liljegren, Boukabara, Cady-Pereira, and 
Clough, TGARS v. 43, pp 1102-1108, 2005) that the half-width of the 
22 GHz water vapor line from the HITRAN compilation, which is 5 percent 
smaller than the Liebe and Dillon (1969) half-width used in Rosenkranz 
(1998), provided a better fit to the microwave brightness temperature 
measurements at 5 frequencies in the range 22-30 GHz, and yielded more 
accurate retrievals. Accordingly, revised MWR retrieval coefficients 
have been developed using MONORTM, which utilizes the HITRAN compilation 
for its spectroscopic parameters.  These new retrievals provide 3 
percent less PWV and 2.6 percent greater LWP than the previous 
retrievals based on Rosenkranz (1998).

Although the MWR data will be reprocessed to apply the new monortm-based 
retrievals, for most purposes it will be sufficient to correct the data 
using the following factors:

PWV_MONORTM = 0.9695 * PWV_ROSENKRANZ
LWP_MONORTM = 1.026  * LWP_ROSENKRANZ

The Rosenkranz-based retrieval coefficients became active at SGP.E14 
20020416.0000.  The MONORTM-based retrieval coefficients became active 
at SGP.E14 20050628.2300.

Note: a reprocessing effort is already underway to apply the 
Rosenkranz-based retrieval coefficients to all MWR prior to April 
2002.  An additional reprocessing task will be undertaken to apply 
the MONORTM retrieval to all MWR data when the first is completed. 
Read reprocessing comments in the netcdf file header carefully to 
ensure you are aware which retrieval is in play.
Measurements:sgpmwrlosE14.a1:
  • MWR column precipitable water vapor(vap)
  • Averaged total liquid water along LOS path(liq)

sgpmwrtipE14.a1:
  • Total liquid water along zenith path using tip-derived brightness temperatures(liqtip)
  • Total water vapor along zenith path using tip-derived brightness temperatures(vaptip)

sgpmwrlosE14.b1:
  • Averaged total liquid water along LOS path(liq)
  • MWR column precipitable water vapor(vap)

sgpqmemwrcolE14.c1:
  • Ensemble average for MWR vapor in window centered about balloon release(mean_vap_mwr)
  • Ensemble average for MWR liquid in window centered about balloon release(mean_liq_mwr)


Back To Table of Contents

DQRID : D051011.3
Start DateStart TimeEnd DateEnd Time
05/01/2002145808/01/20052306
Subject:
SGP/MWR/E14 - New software version (4.15) installed
DataStreams:sgpmwrlosE14.b1, sgpmwrtipE14.a1
Description:
A problem began with the installation of MWR.EXE version 4.12 in May 2002. The software 
had been upgraded from a "DOS" to a "Windows"-compiled program to address an earlier 
problem.  The software upgrade corrected the earlier problem but introduced a new one that 
caused line-of-sight observing cycles to be skipped, a 15% reduction in the number of tip 
curves, and saturation of CPU usage. Software versions 4.13 and 4.14 also produced these 
problems.

The new MWR software, version 4.15, was installed on 8/1/2005. As a consequence of this 
upgrade, the tip curve frequency increased. The tip cycle time decreased from ~60s to ~50s.
Measurements:sgpmwrtipE14.a1:
  • 23.8 GHz goodness-of-fit coefficient(r23)
  • (tknd)
  • Temperature correction coefficient at 23.8 GHz(tc23)
  • Noise injection temp at 31.4 GHz adjusted to tkbb(tnd31)
  • 31.4 GHz blac2body+noise injection signal(bbn31)
  • 31.4 GHz blackbody(bb31)
  • Total water vapor along zenith path using tip-derived brightness temperatures(vaptip)
  • Mixer kinetic (physical) temperature(tkxc)
  • 31.4 GHz sky signal(tipsky31)
  • Noise injection temp at 31.4 GHz derived from this tip(tnd31I)
  • Total liquid water along zenith path using tip-derived brightness temperatures(liqtip)
  • Noise injection temp at 23.8 GHz derived from this tip(tnd23I)
  • Noise injection temp at nominal temperature at 31.4 GHz(tnd_nom31)
  • 23.8 GHz Blackbody signal(bb23)
  • Noise injection temp at 23.8 GHz adjusted to tkbb(tnd23)
  • Ambient temperature(tkair)
  • Temperature correction coefficient at 31.4 GHz(tc31)
  • 31.4 GHz goodness-of-fit coefficient(r31)
  • 31.8 GHz sky brightness temperature derived from tip curve(tbskytip31)
  • 23.8 GHz sky brightness temperature derived from tip curve(tbskytip23)
  • Blackbody kinetic temperature(tkbb)
  • 23.8 GHz sky signal(tipsky23)
  • Noise injection temp at nominal temperature at 23.8 GHz(tnd_nom23)
  • 23.8 GHz blackbody+noise injection signal(bbn23)

sgpmwrlosE14.b1:
  • Averaged total liquid water along LOS path(liq)
  • Noise injection temp at nominal temperature at 31.4 GHz(tnd_nom31)
  • Mean 23.8 GHz sky brightness temperature(tbsky23)
  • MWR column precipitable water vapor(vap)
  • 23.8 GHz blackbody+noise injection signal(bbn23)
  • 31.4 GHz blac2body+noise injection signal(bbn31)
  • 23.8 GHz Blackbody signal(bb23)
  • Mean 31.4 GHz sky brightness temperature(tbsky31)
  • Noise injection temp at 23.8 GHz adjusted to tkbb(tnd23)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • (tknd)
  • 23.8 GHz sky signal(sky23)
  • Blackbody kinetic temperature(tkbb)
  • Temperature correction coefficient at 31.4 GHz(tc31)
  • Ambient temperature(tkair)
  • Noise injection temp at 31.4 GHz adjusted to tkbb(tnd31)
  • Mixer kinetic (physical) temperature(tkxc)
  • 31.4 GHz blackbody(bb31)
  • Temperature correction coefficient at 23.8 GHz(tc23)
  • Noise injection temp at nominal temperature at 23.8 GHz(tnd_nom23)
  • 31.4 GHz sky signal(sky31)


Back To Table of Contents



END OF DATA