Data Quality Reports for Session: 108985 User: kjohnson Completed: 11/19/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060517.3TWP/VCEIL/C2 - Vceil computer disconnectedtwpvceil25kC2.b1
D060717.5TWP/VCEIL/C2 - Time offsettwpvceil25kC2.b1
D060818.2TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC2.b1
D061011.3TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC2.b1


DQRID : D060517.3
Start DateStart TimeEnd DateEnd Time
05/13/2006224905/15/20060410
Subject:
TWP/VCEIL/C2 - Vceil computer disconnected
DataStreams:twpvceil25kC2.b1
Description:
VCEIL computer was disconnected during this time period.
Measurements:twpvceil25kC2.b1:
  • Aerosol backscatter coefficient at 355 nm(backscatter)
  • Flag indicating aeri retrieval status(status_flag)
  • Percentage of nominal factory setting (0 to 999%)(laser_pulse_energy)
  • Third cloud base height(third_cbh)
  • Time offset of tweaks from base_time(time_offset)
  • base time(base_time)
  • Lowest cloud base height detected.(first_cbh)
  • Warning and alarm status bits(status_string)
  • range(range)
  • Millivolts at internal ADC input (0 to 2500)(background_light)
  • Percentage of nominal factory setting (0 to 999%)(receiver_sensitivity)
  • Vertical visibility(vertical_visibility)
  • Laser temperature(laser_temperature)
  • Altitude of highest signal(alt_highest_signal)
  • 6 character string describing instrument measurement parameters(measurement_parameters)
  • Second lowest cloud base height(second_cbh)
  • GPS raw data filename(filename)
  • Degrees from vertical (0 to +90)(tilt_angle)
  • Detection status. See details(detection_status)
  • Millivolts at internal ADC input(window_contamination)
  • Backscatter sum(sum_backscatter)


Back To Table of Contents

DQRID : D060717.5
Start DateStart TimeEnd DateEnd Time
05/13/2006222407/17/20061912
Subject:
TWP/VCEIL/C2 - Time offset
DataStreams:twpvceil25kC2.b1
Description:
On 7/14/2006, I found that the ceilometer time was 8m 36s slow, the PC time display (lower 
right taskbar) was frozen at "22:24", and AboutTime was not running. Corrected it on 
7/17 by running AboutTime so that 19:03:29 became 19:12:05. This also corrected the frozen 
display on the Windows98 taskbar. 

I am not sure of the start time of this problem but there were several other Windows 
related issues that had to be corrected on 5/14 with indications of inappropriate access via 
Remote Administrator on 5/13. I do not know if the time offset was a sudden or gradual 
change.
Measurements:twpvceil25kC2.b1:
  • Aerosol backscatter coefficient at 355 nm(backscatter)
  • Flag indicating aeri retrieval status(status_flag)
  • Percentage of nominal factory setting (0 to 999%)(laser_pulse_energy)
  • Third cloud base height(third_cbh)
  • Time offset of tweaks from base_time(time_offset)
  • base time(base_time)
  • Lowest cloud base height detected.(first_cbh)
  • Warning and alarm status bits(status_string)
  • range(range)
  • Millivolts at internal ADC input (0 to 2500)(background_light)
  • Percentage of nominal factory setting (0 to 999%)(receiver_sensitivity)
  • Vertical visibility(vertical_visibility)
  • Laser temperature(laser_temperature)
  • Altitude of highest signal(alt_highest_signal)
  • 6 character string describing instrument measurement parameters(measurement_parameters)
  • Second lowest cloud base height(second_cbh)
  • Degrees from vertical (0 to +90)(tilt_angle)
  • Detection status. See details(detection_status)
  • Millivolts at internal ADC input(window_contamination)
  • Backscatter sum(sum_backscatter)


Back To Table of Contents

DQRID : D060818.2
Start DateStart TimeEnd DateEnd Time
10/21/1998000007/13/20062232
Subject:
TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC2.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.3
Start DateStart TimeEnd DateEnd Time
10/21/1998000011/29/20062014
Subject:
TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC2.b1
Description:
A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. 
Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC2.b1 datastream.  Between 9/26 and 11/29, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros are 
not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19981021-20060926 and data from 
19981021-20061129 will be filled with -9999 (missing).
Measurements:twpsmet60sC2.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA