DQR ID | Subject | Data Streams Affected |
---|---|---|
D040228.1 | TWP/SONDE/C1 - Broken temperature sensor | twpsondewnpnC1.b1 |
D041011.3 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D050105.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D050201.2 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2004 | 2342 | 02/08/2004 | 0115 |
02/09/2004 | 1133 | 02/09/2004 | 1233 |
04/05/2004 | 2332 | 04/06/2004 | 0105 |
04/22/2004 | 1156 | 04/22/2004 | 1317 |
04/24/2004 | 1130 | 04/24/2004 | 1312 |
04/29/2004 | 1137 | 04/29/2004 | 1312 |
04/30/2004 | 2336 | 05/01/2004 | 0112 |
05/03/2004 | 2331 | 05/04/2004 | 0105 |
05/05/2004 | 1135 | 05/05/2004 | 1319 |
05/07/2004 | 1132 | 05/07/2004 | 1315 |
05/11/2004 | 1142 | 05/11/2004 | 1311 |
05/12/2004 | 1145 | 05/12/2004 | 1206 |
05/18/2004 | 1130 | 05/18/2004 | 1321 |
07/10/2004 | 1130 | 07/11/2004 | 1255 |
07/13/2004 | 1139 | 07/13/2004 | 1320 |
07/16/2004 | 2346 | 07/17/2004 | 0107 |
07/22/2004 | 2355 | 07/23/2004 | 0140 |
07/26/2004 | 2341 | 07/27/2004 | 0115 |
08/14/2004 | 2330 | 08/15/2004 | 0104 |
08/22/2004 | 2335 | 08/23/2004 | 0105 |
09/05/2004 | 2340 | 09/06/2004 | 0119 |
09/14/2004 | 2328 | 09/14/2004 | 2329 |
09/17/2004 | 2332 | 09/18/2004 | 0102 |
10/28/2004 | 2336 | 10/29/2004 | 0057 |
11/28/2004 | 2352 | 11/29/2004 | 0044 |
Subject: | TWP/SONDE/C1 - Broken temperature sensor |
DataStreams: | twpsondewnpnC1.b1 |
Description: | The temperature sensor on these radiosondes broke after launch All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/08/2004 | 1131 | 10/08/2004 | 1200 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~1 %RH) and high (~80 %RH). According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2004 | 2330 | 12/31/2004 | 0108 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~5 %RH) and not so low (~70 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/2005 | 2330 | 01/08/2005 | 0102 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 12km). The RH oscillates rapidly between low (~2 %RH) and not so low (~80 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|