DQR ID | Subject | Data Streams Affected |
---|---|---|
D020614.3 | SGP/SMOS/E8 - Reprocess: Wind speed calibration | sgp1smosE8.a0, sgp30smosE8.a1 |
D020619.3 | SGP/SMOS/E8 - Incorrect E8 SMOS rain data | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
D040317.8 | SGP/SMOS/E8 - 6-month Calibration Checks | sgp1440smosE8.a0, sgp1smosE8.a0, sgp30smosE8.a1 |
D951009.3 | SGP/SMOS/E8 - Reprocess: Incorrect wind speed calibration | sgp1440smosE8.a0, sgp1smosE8.a0, sgp30smosE8.a1 |
D971006.1 | SGP/SMOS/E8 - Reprocess: Incorrect wind directions from E8 SMOS | sgp1smosE8.a0, sgp30smosE8.a1 |
D971112.10 | SGP/SMOS/E8 - Questionable E8 SMOS rain data | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
D980401.3 | SGP/SMOS/E8 - Icing affected E8 SMOS wind speed | sgp1440smosE8.a0, sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/28/1993 | 0001 | 08/11/1993 | 1530 |
Subject: | SGP/SMOS/E8 - Reprocess: Wind speed calibration |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | EDITOR'S NOTE: The earliest portion of the period of time covered by this DQR occurred prior to the begin date of regular ARM data. Those data are not readily available from the ARM archive, but are available upon request. The actual period of time covered by this DQR is 930403.0000-930811.1530. Practically all of the information in this DQR is derived from P930723.1 and C930830.1, both of which were submitted by Dick Hart. The calibrations initially used for wind speeds on SMOS systems at Coldwater (E8), Ashton (E9), the central faciality (E13), Ringwood (E15), and Meeker (E20) were originally "generic"values, but analysis of the N.I.S.T traceable calibration data reveals that use of these "generic" calibrations produces data with insufficient accuracy. The calibrations for the wind speed sensor associated with the instrument must be used in the datalogger program in order to obtain data with a 1% uncertainty. For the worst case, one wind speed sensor underestimates the wind speed by 1.1 m/s at 30 m/s when the "generic" calibration is used. This is on top of the 1% calibration uncertainty. No unreported data loss occurred as a result of this calibration question, but users of the data should adjust the wind speed values before analysis involving these wind speed values. |
Measurements: | sgp1smosE8.a0:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/16/1997 | 0000 | 10/29/1997 | 1815 |
Subject: | SGP/SMOS/E8 - Incorrect E8 SMOS rain data |
DataStreams: | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | The E8 SMOS rain gauge pulse counter was found to be non-operational during the 16 SEP 97 PM. It was repaired by replacing the CR10 wiring harness on 29 OCT 97 at 1815 GMT. |
Measurements: | sgp1smosE8.a0:
sgp1smosE8.00:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/15/1994 | 1525 | 06/15/1994 | 1725 |
11/16/1994 | 1458 | 11/16/1994 | 1658 |
04/19/1995 | 1717 | 04/19/1995 | 1818 |
10/02/1995 | 1940 | 10/02/1995 | 2215 |
04/17/1996 | 1400 | 04/17/1996 | 1730 |
10/30/1996 | 1550 | 10/30/1996 | 1730 |
04/29/1997 | 1930 | 04/29/1997 | 2000 |
10/28/1997 | 2000 | 10/28/1997 | 2300 |
10/29/1997 | 1815 | 10/29/1997 | 1910 |
04/28/1998 | 2035 | 04/28/1998 | 2110 |
11/23/1998 | 1900 | 11/23/1998 | 1940 |
04/27/1999 | 1735 | 04/27/1999 | 2300 |
09/28/1999 | 1910 | 09/28/1999 | 1930 |
04/25/2000 | 1636 | 04/25/2000 | 1707 |
10/24/2000 | 1648 | 10/24/2000 | 1800 |
Subject: | SGP/SMOS/E8 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE8.a0, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | During the time periods specified, the SMOS.E8 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE8.a0:
sgp1440smosE8.a0:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/10/1995 | 0000 | 10/02/1995 | 2215 |
Subject: | SGP/SMOS/E8 - Reprocess: Incorrect wind speed calibration |
DataStreams: | sgp1440smosE8.a0, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | The wrong data logger program file was loaded into the data logger. The best guess is that this was done when the system was relocated on 10 MAY 95. It was discovered and corrected during the 6 month sensor verification. |
Measurements: | sgp1smosE8.a0:
sgp1440smosE8.a0:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/1997 | 2000 | 09/30/1997 | 2100 |
Subject: | SGP/SMOS/E8 - Reprocess: Incorrect wind directions from E8 SMOS |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | When the Wind Monitor was changed at E8 for scheduled PM, the replacement sensor was incorrectly wired to the data logger. It did not effect the wind speed readings, but wind directions had E and W reversed. Thus winds from 15 deg were reported as being from 345 deg, and vice-versa, and winds from 165 deg were reported as being from 195 degrees, and vice-versa. |
Measurements: | sgp1smosE8.a0:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/02/1997 | 0000 | 09/16/1997 | 0000 |
Subject: | SGP/SMOS/E8 - Questionable E8 SMOS rain data |
DataStreams: | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | The E8 SMOS rain gauge pulse counter was found to be non-operational during the 16 SEP 97 PM. It was repaired by replacing the CR10 wiring harness on 29 OCT 97 at 1815 GMT. |
Measurements: | sgp1smosE8.a0:
sgp1smosE8.00:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/16/1998 | 1400 | 03/17/1998 | 1630 |
Subject: | SGP/SMOS/E8 - Icing affected E8 SMOS wind speed |
DataStreams: | sgp1440smosE8.a0, sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | Icing conditions at E8 caused the SMOS wind speed data to be questionable between 1400 and 2130 GMT on 16 MAR 98 and again between 0430 and 1630 GMT on 17 MAR 98. The data appear to be unaffected between those two periods, but may also be questionable. |
Measurements: | sgp1smosE8.a0:
sgp1440smosE8.a0:
sgp1smosE8.00:
sgp30smosE8.a1:
|