DQR ID | Subject | Data Streams Affected |
---|---|---|
D040126.3 | SGP/SIRS/E21 - False signal | sgpsirs20sE21.a0, sgpsirsE21.00, sgpsirsE21.b1 |
D040205.1 | SGP/SIRS/E1/E2/E3/E5/E8 - Snow on Radiometers | sgpsirs20sE1.a0, sgpsirs20sE2.a0, sgpsirs20sE3.a0, sgpsirs20sE5.a0, sgpsirs20sE8.a0, sgpsirsE1.00, sgpsirsE1.b1, sgpsirsE2.00, sgpsirsE2.b1, sgpsirsE3.00, sgpsirsE3.b1, sgpsirsE5.00, sgpsirsE5.b1, sgpsirsE8.00, sgpsirsE8.b1 |
D040226.1 | SGP/SIRS/E9 - PSP dome contamination | sgpsirs20sE9.a0, sgpsirsE9.00, sgpsirsE9.b1 |
D040226.2 | SGP/SIRS/E11 - PSP dome contamination | sgpsirs20sE11.a0, sgpsirsE11.00, sgpsirsE11.b1 |
D040227.2 | SGP/SIRS/E16 - Tracker Misaligned | sgpsirs20sE16.a0, sgpsirsE16.b1 |
D040227.3 | SGP/SIRS/E2 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE2.00, sgpsirsE2.b1 |
D040227.4 | SGP/SIRS/E15 - PSP dome contamination | sgpsirs20sE15.a0, sgpsirsE15.b1 |
D040229.2 | SGP/SIRS/E21 - Shadowband Misalignment | sgpsirs20sE21.a0, sgpsirsE21.00, sgpsirsE21.b1 |
D040303.1 | SGP/SIRS/E16 - PSP Dome Contamination | sgpsirs20sE16.a0, sgpsirsE16.b1 |
D040615.5 | SGP/SIRS/E12 - Incorrect Times | sgp15swfanalsirs1longE12.c1, sgp1swfanalsirs1longE12.c1, sgpsirs20sE12.a0, sgpsirsE12.00, sgpsirsE12.b1 |
D040831.1 | SGP/SIRS/E1 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE1.00, sgpsirsE1.b1 |
D040831.2 | SGP/SIRS/E7 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE7.00, sgpsirsE7.b1 |
D040831.3 | SGP/SIRS/E8 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE8.00, sgpsirsE8.b1 |
D040831.4 | SGP/SIRS/E10 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE10.00, sgpsirsE10.b1 |
D040831.5 | SGP/SIRS/E11 - Reprocess: Incorrect shortwave radiometer calibration coefficients | sgpsirsE11.00, sgpsirsE11.b1 |
D060630.10 | SGP/SIRS/E2 - Reprocessed: Longwave Calibration error | sgpsirsE2.b1 |
D060630.15 | SGP/SIRS/E7 - Reprocessed: Longwave Calibration error | sgpsirsE7.b1 |
D060630.16 | SGP/SIRS/E8 - Reprocessed: Longwave Calibration error | sgpsirsE8.b1 |
D060630.17 | SGP/SIRS/E9 - Reprocessed: Longwave Calibration error | sgpsirsE9.b1 |
D060630.18 | SGP/SIRS/E10 - Reprocessed: Longwave Calibration error | sgpsirsE10.b1 |
D060630.19 | SGP/SIRS/E11 - Reprocessed: Longwave Calibration error | sgpsirsE11.b1 |
D060630.20 | SGP/SIRS/E12 - Reprocessed: Longwave Calibration error | sgpsirsE12.b1 |
D060630.21 | SGP/SIRS/E13 - Reprocessed: Longwave Calibration error | sgpsirsE13.b1 |
D060630.22 | SGP/SIRS/E15 - Reprocessed: Longwave Calibration error | sgpsirsE15.b1 |
D060630.23 | SGP/SIRS/E16 - Reprocessed: Longwave Calibration error | sgpsirsE16.b1 |
D060630.24 | SGP/SIRS/E18 - Reprocessed: Longwave Calibration error | sgpsirsE18.b1 |
D060630.25 | SGP/SIRS/E19 - Reprocessed: Longwave Calibration error | sgpsirsE19.b1 |
D060630.26 | SGP/SIRS/E20 - Reprocessed: Longwave Calibration error | sgpsirsE20.b1 |
D060630.27 | SGP/SIRS/E21 - Reprocessed: Longwave Calibration error | sgpsirsE21.b1 |
D060630.28 | SGP/SIRS/E22 - Reprocessed: Longwave Calibration error | sgpsirsE22.b1 |
D060630.29 | SGP/SIRS/E24 - Reprocessed: Longwave Calibration error | sgpsirsE24.b1 |
D060630.30 | SGP/SIRS/E27 - Reprocessed: Longwave Calibration error | sgpsirsE27.b1 |
D060630.8 | SGP/SIRS/C1 - Reprocessed: Longwave Calibration error | sgpsirsC1.b1 |
D060630.9 | SGP/SIRS/E1 - Reprocessed: Longwave Calibration error | sgpsirsE1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/19/2003 | 0000 | 02/26/2004 | 2359 |
Subject: | SGP/SIRS/E21 - False signal |
DataStreams: | sgpsirs20sE21.a0, sgpsirsE21.00, sgpsirsE21.b1 |
Description: | During clear-sky conditions, downwelling shortwave values spike downward approximately 50 to 200 W/m^2 around 22:15 UTC for about 15 minutes. This problem occurs at about the same time for the same duration each day during the indicated period of the year. This effect is due to a shadow from the Rotating Bird Deterrent (RBD) installed earlier in the year to prevent extensive bird droppings at the site. The RBD is installed at such a location that it will partially shade the downwelling shortwave PSP from 19 October to 23 February of the year. |
Measurements: | sgpsirsE21.00:
sgpsirs20sE21.a0:
sgpsirsE21.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 1200 | 02/02/2004 | 2000 |
Subject: | SGP/SIRS/E1/E2/E3/E5/E8 - Snow on Radiometers |
DataStreams: | sgpsirs20sE1.a0, sgpsirs20sE2.a0, sgpsirs20sE3.a0, sgpsirs20sE5.a0, sgpsirs20sE8.a0, sgpsirsE1.00, sgpsirsE1.b1, sgpsirsE2.00, sgpsirsE2.b1, sgpsirsE3.00, sgpsirsE3.b1, sgpsirsE5.00, sgpsirsE5.b1, sgpsirsE8.00, sgpsirsE8.b1 |
Description: | A large discrepancy between the measured values of downwelling hemispheric shortwave radiation and the derived values occurred on 2/02 at the listed sites. The difference is on the order of 200 Wm^(-2) at E2 and to a lesser extent at the other affected stations. This problem most likely resulted from a previous day or night snow/ice accumulation on the Direct(NIP), Downwelling Sortwave(PSP) and/or Downwelling Diffuse(8-48) instruments. During the morning hours of 02/02, Approx 1300-2000GMT, snow/ice was covering one or more of these three instruments resulting in faulty readings and incorrect derived downwelling shortwave values as well. Instrument readings indicate the problem resolved itself later in the day through normal meltoff. |
Measurements: | sgpsirs20sE5.a0:
sgpsirsE2.b1:
sgpsirsE1.00:
sgpsirsE2.00:
sgpsirs20sE3.a0:
sgpsirsE3.b1:
sgpsirs20sE1.a0:
sgpsirsE8.00:
sgpsirsE3.00:
sgpsirsE5.b1:
sgpsirsE1.b1:
sgpsirsE5.00:
sgpsirs20sE2.a0:
sgpsirs20sE8.a0:
sgpsirsE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1600 | 02/23/2004 | 0500 |
Subject: | SGP/SIRS/E9 - PSP dome contamination |
DataStreams: | sgpsirs20sE9.a0, sgpsirsE9.00, sgpsirsE9.b1 |
Description: | Measured values of diffuse shortwave downwelling radiation fluctuated below derived values of downwelling shortwave radiation by 50 W/m^2 during the afternoon hours under clear conditions. SMOS precipitation and wind speed data reveals rain and wind the night before on 02/20/03 0100 GMT probably contaminated the PSP dome with dirt. Precipitation of .25mm on 02/23/04 0300 seems to have effectively cleared the PSP dome since PSP data on 02/24/04 compares correctly to direct and diffuse components. |
Measurements: | sgpsirs20sE9.a0:
sgpsirsE9.b1:
sgpsirsE9.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1500 | 03/01/2004 | 1300 |
Subject: | SGP/SIRS/E11 - PSP dome contamination |
DataStreams: | sgpsirs20sE11.a0, sgpsirsE11.00, sgpsirsE11.b1 |
Description: | Measured values of diffuse shortwave downwelling radiation fluctuated below derived values of downwelling shortwave radiation during the afternoon hours under clear conditions, probably due to a dirty PSP dome. SMOS precipitation and wind speed data reveal rain and wind on 02/19/03 at 2300 GMT probably contaminated the PSP dome with dirt. Precipitation of .4mm on 02/29/04 1400 seems to have effectively cleared the PSP dome since PSP data on 03/01/04 compares correctly to direct and diffuse components. |
Measurements: | sgpsirsE11.b1:
sgpsirsE11.00:
sgpsirs20sE11.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/06/2004 | 2200 | 02/18/2004 | 1605 |
Subject: | SGP/SIRS/E16 - Tracker Misaligned |
DataStreams: | sgpsirs20sE16.a0, sgpsirsE16.b1 |
Description: | Direct Normal Shortwave (NIP) values may be reduced by tracker misalignment (tracker clock slow by 2 minutes 10 sec on 2/18/04). Downwelling Diffuse (DD) values may be increased by the tracker misalignment. Error amounts can not be accurately quantified. |
Measurements: | sgpsirsE16.b1:
sgpsirs20sE16.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/12/2004 | 1612 | 03/25/2004 | 1600 |
Subject: | SGP/SIRS/E2 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE2.00, sgpsirsE2.b1 |
Description: | During the pyrgeometer instrument (PIR) changout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements were : downwelling diffuse (DD), upwelling shortwave(US), direct normal (NIP) and downwelling shortwave(DS) Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*118.11 US(corrected) = (US/113.19)*118.21 NIP(corrected)= (NIP/120.17)*119.08 DS(corrected) = (DS/118.46)*117.33 |
Measurements: | sgpsirsE2.b1:
sgpsirsE2.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1900 | 02/29/2004 | 1700 |
Subject: | SGP/SIRS/E15 - PSP dome contamination |
DataStreams: | sgpsirs20sE15.a0, sgpsirsE15.b1 |
Description: | PSP dome was dirty. Afternoon values of downwelling shortwave radiation were less than derived values by about 50 W/m^2. PSP values compare well to derived PSP values after precip event on 02/29/04 1300-1600 GMT. Maintenance on 03/02 1713 GMT revealed no unusual contamination. Precip on 02/29 likely effectively cleaned the PSP dome. |
Measurements: | sgpsirsE15.b1:
sgpsirs20sE15.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1300 | 03/03/2004 | 1300 |
Subject: | SGP/SIRS/E21 - Shadowband Misalignment |
DataStreams: | sgpsirs20sE21.a0, sgpsirsE21.00, sgpsirsE21.b1 |
Description: | The NIP reported values close to zero and downwelling shortwave global and diffuse were equivalent due to tracker failure. Maintenance replaced tracker 2/27, but couldn't replace instruments until 03/02 2000 GMT due to bird poop contamination. |
Measurements: | sgpsirsE21.00:
sgpsirs20sE21.a0:
sgpsirsE21.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/06/2004 | 2200 | 02/18/2004 | 1605 |
Subject: | SGP/SIRS/E16 - PSP Dome Contamination |
DataStreams: | sgpsirs20sE16.a0, sgpsirsE16.b1 |
Description: | Downwelling Shortwave (DS) values near 22:00 GMT during clear skys are lower than expected due to contamination of pyranometer dome. A dime-sized spot of dirt was found on the southwest portion of the pyranometer dome. DS values for cloudy conditions during this period are also suspect, but the amount of irradiance reduction are not significant. |
Measurements: | sgpsirsE16.b1:
sgpsirs20sE16.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/19/2004 | 2212 | 03/10/2004 | 2247 |
Subject: | SGP/SIRS/E12 - Incorrect Times |
DataStreams: | sgp15swfanalsirs1longE12.c1, sgp1swfanalsirs1longE12.c1, sgpsirs20sE12.a0, sgpsirsE12.00, sgpsirsE12.b1 |
Description: | The ntpd server (time adjustment) stopped working on Feb. 19th at 22:12:16 GMT, and the clock was corrected by -5600.177269 seconds on March 10th at 22:47 GMT. The recorded times for observations are off by amounts ranging from 0 seconds on Feb. 19th to 5600 seconds on March 10th. |
Measurements: | sgp1swfanalsirs1longE12.c1:
sgpsirsE12.b1:
sgp15swfanalsirs1longE12.c1:
sgpsirs20sE12.a0:
sgpsirsE12.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/10/2004 | 2050 | 04/20/2004 | 2015 |
Subject: | SGP/SIRS/E1 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE1.00, sgpsirsE1.b1 |
Description: | During the pyrgeometer instrument (PIR) changout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements (instruments) were : downwelling diffuse (8-48), upwelling shortwave(PSP), direct normal (NIP) and downwelling shortwave (PSP) Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*109.01 US(corrected) = (US/113.19)*111.47 NIP(corrected)= (NIP/120.17)*114.82 DS(corrected) = (DS/118.46)*116.51 |
Measurements: | sgpsirsE1.b1:
sgpsirsE1.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1845 | 04/20/2004 | 1825 |
Subject: | SGP/SIRS/E7 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE7.00, sgpsirsE7.b1 |
Description: | During the pyrgeometer instrument (PIR) changout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements (instruments) were : downwelling diffuse (8-48), upwelling shortwave(PSP), direct normal (NIP) and downwelling shortwave (PSP) Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*108.50 US(corrected) = (US/113.19)*110.10 NIP(corrected)= (NIP/120.17)*122.26 DS(corrected) = (DS/118.46)*122.56 |
Measurements: | sgpsirsE7.b1:
sgpsirsE7.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/10/2004 | 1825 | 04/20/2004 | 1825 |
Subject: | SGP/SIRS/E8 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE8.00, sgpsirsE8.b1 |
Description: | During the pyrgeometer instrument (PIR) changeout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements (instruments) were: downwelling diffuse (8-48), upwelling shortwave (PSP), direct normal (NIP) and downwelling shortwave (PSP) Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*116.37 US(corrected) = (US/113.19)*121.78 NIP(corrected)= (NIP/120.17)*122.47 DS(corrected) = (DS/118.46)*122.34 |
Measurements: | sgpsirsE8.00:
sgpsirsE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1630 | 04/21/2004 | 1425 |
Subject: | SGP/SIRS/E10 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE10.00, sgpsirsE10.b1 |
Description: | During the pyrgeometer instrument (PIR) changeout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements (instruments) were: downwelling diffuse (8-48), upwelling shortwave (PSP), direct normal (NIP) and downwelling shortwave (PSP) Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For SGP/SIRS/E10 and each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*114.63 US(corrected) = (US/113.19)*117.46 NIP(corrected)= (NIP/120.17)*119.26 DS(corrected) = (DS/118.46)*122.78 |
Measurements: | sgpsirsE10.b1:
sgpsirsE10.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/17/2004 | 1741 | 05/05/2004 | 0000 |
Subject: | SGP/SIRS/E11 - Reprocess: Incorrect shortwave radiometer calibration coefficients |
DataStreams: | sgpsirsE11.00, sgpsirsE11.b1 |
Description: | During the pyrgeometer instrument (PIR) changeout a datalogger program was loaded with incorrect calibration coefficients for the shortwave instruments. The affected measurements (instruments) were: downwelling diffuse (8-48), upwelling shortwave (PSP), direct normal (NIP) and downwelling shortwave (PSP) Field tech reports the datalogger program was corrected on 4/27/04. Archive data review shows this was not the case and the corrected datalogger program was uploaded sometime late day 5/4/04. The end date for this DQR was chosen to be 5/5/04 0000 the first full day of the correct datalogger program. Recalculate irradiances by determining original mV signal and reapplying the correct calibration coefficients. For each one minute irradiance value perform the following calculations by instrument: DD(corrected) = (DD/107.24)*123.27 US(corrected) = (US/113.19)*127.75 NIP(corrected)= (NIP/120.17)*126.69 DS(corrected) = (DS/118.46)*126.56 |
Measurements: | sgpsirsE11.b1:
sgpsirsE11.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/12/2004 | 1630 | 02/23/2005 | 1615 |
Subject: | SGP/SIRS/E2 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE2.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in February 2004. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instanteous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in September 2006. |
Measurements: | sgpsirsE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 2000 | 02/07/2006 | 2005 |
Subject: | SGP/SIRS/E7 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE7.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in February 2004. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/10/2004 | 1845 | 02/21/2006 | 1840 |
Subject: | SGP/SIRS/E8 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE8.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in February 2004. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instanteous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in September 2006. |
Measurements: | sgpsirsE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/17/2003 | 1640 | 02/07/2006 | 1730 |
Subject: | SGP/SIRS/E9 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE9.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instanteous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE9.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1730 | 02/07/2006 | 2130 |
Subject: | SGP/SIRS/E10 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE10.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in February 2004. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in August 2006. |
Measurements: | sgpsirsE10.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/17/2004 | 1753 | 02/14/2006 | 2016 |
Subject: | SGP/SIRS/E11 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE11.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in February 2004. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in August 2006. |
Measurements: | sgpsirsE11.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/22/2003 | 1640 | 02/14/2006 | 1710 |
Subject: | SGP/SIRS/E12 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE12.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE12.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/11/2003 | 1935 | 02/16/2006 | 1905 |
Subject: | SGP/SIRS/E13 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE13.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/22/2003 | 1650 | 02/14/2006 | 1806 |
Subject: | SGP/SIRS/E15 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE15.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/23/2003 | 1605 | 02/15/2006 | 1533 |
Subject: | SGP/SIRS/E16 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE16.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE16.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/22/2003 | 2200 | 02/14/2006 | 2100 |
Subject: | SGP/SIRS/E18 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE18.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/24/2003 | 1600 | 02/16/2006 | 1558 |
Subject: | SGP/SIRS/E19 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE19.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/23/2003 | 2100 | 02/15/2006 | 2030 |
Subject: | SGP/SIRS/E20 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE20.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in November 2006. |
Measurements: | sgpsirsE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/23/2003 | 1520 | 02/15/2006 | 1515 |
Subject: | SGP/SIRS/E21 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE21.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in November 2006. |
Measurements: | sgpsirsE21.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/23/2003 | 1830 | 02/15/2006 | 1741 |
Subject: | SGP/SIRS/E22 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE22.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in August 2006. |
Measurements: | sgpsirsE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/24/2003 | 1640 | 02/16/2006 | 1705 |
Subject: | SGP/SIRS/E24 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE24.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in July 2004. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE24.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/16/2003 | 0002 | 02/15/2006 | 1750 |
Subject: | SGP/SIRS/E27 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE27.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in May 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE27.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/11/2003 | 1950 | 02/16/2006 | 1901 |
Subject: | SGP/SIRS/C1 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsC1.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/10/2004 | 2055 | 02/21/2006 | 2007 |
Subject: | SGP/SIRS/E1 - Reprocessed: Longwave Calibration error |
DataStreams: | sgpsirsE1.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in February 2004. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place have been reprocessed to remove the calibration bias. The reprocessed 60 second averaged data are based on 3 instantaneous 20 second data records rather than on 60 1 second instantaneous data records. Still, these data are considered far superior to the originally processed data. The reprocessed data were archived in October 2006. |
Measurements: | sgpsirsE1.b1:
|