Subject: | SGP/IRT25m/C1 - error in data logger program |
DataStreams: | sgpirt25m20sC1.a0, sgpirt25mC1.a1
|
Description: | On 12/16/2002, the logger software for the IRT25m was
inappropriately edited. This resulted in incorrect instantaneous
values at 20 and 40 seconds after each minute and incorrect
calculation of 60-second averaged instantaneous values (because
the 20 and 40 second values are two of three instantaneous
values used to calculate this average). On 5/21/2003, the data
logger program was corrected. |