DQR ID | Subject | Data Streams Affected |
---|---|---|
D020619.3 | SGP/SMOS/E8 - Incorrect E8 SMOS rain data | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
D040315.1 | SGP/SMOS/E1 - 6-month Calibration Checks | sgp1440smosE1.a0, sgp1smosE1.a0, sgp30smosE1.a1 |
D040315.4 | SGP/SMOS/E3 - 6-month Calibration Checks | sgp1440smosE3.a0, sgp1smosE3.a0, sgp30smosE3.a1 |
D040316.1 | SGP/SMOS/E4 - 6-month Calibration Checks | sgp1440smosE4.a0, sgp1smosE4.a0, sgp30smosE4.a1 |
D040316.4 | SGP/SMOS/E5 - 6-month Calibration Checks | sgp1440smosE5.a0, sgp1smosE5.a0, sgp30smosE5.a1 |
D040317.2 | SGP/SMOS/E6 - 6-month Calibration Checks | sgp1440smosE6.a0, sgp1smosE6.a0, sgp30smosE6.a1 |
D040317.5 | SGP/SMOS/E7 - 6-month Calibration Checks | sgp1440smosE7.a0, sgp1smosE7.a0, sgp30smosE7.a1 |
D040317.8 | SGP/SMOS/E8 - 6-month Calibration Checks | sgp1440smosE8.a0, sgp1smosE8.a0, sgp30smosE8.a1 |
D040318.1 | SGP/SMOS/E9 - 6-month Calibration Checks | sgp1440smosE9.a0, sgp1smosE9.a0, sgp30smosE9.a1 |
D040318.14 | SGP/SMOS/E15 - 6-month Calibration Checks | sgp1440smosE15.a0, sgp1smosE15.a0, sgp30smosE15.a1 |
D040318.18 | SGP/SMOS/E20 - 6-month Calibration Checks | sgp1440smosE20.a0, sgp1smosE20.a0, sgp30smosE20.a1 |
D040318.5 | SGP/SMOS/E11 - 6-month Calibration Checks | sgp1440smosE11.a0, sgp1smosE11.a0, sgp30smosE11.a1 |
D040318.8 | SGP/SMOS/E13 - 6-month Calibration Checks | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
D040319.6 | SGP/SMOS/E24 - 6-month Calibration Checks | sgp1440smosE24.a0, sgp1smosE24.a0, sgp30smosE24.a1 |
D040319.9 | SGP/SMOS/E25 - 6-month Calibration Checks | sgp1440smosE25.a0, sgp1smosE25.a0, sgp30smosE25.a1 |
D970214.2 | SGP/SMOS/E13 - Questionable data | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
D970325.4 | SGP/SMOS/E24 - RH values exceeding the specified maximum value | sgp1440smosE24.a0, sgp1smosE24.a0, sgp30smosE24.a1 |
D970325.5 | SGP/SMOS/E13 - T/RH Probe Malfunction | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
D970325.6 | SGP/SMOS/E13 - T/RH Probe Malfunction | sgp1smosE13.a0, sgp30smosE13.a1 |
D970325.7 | SGP/SMOS/E13 - T/RH Probe Malfunction | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
D970328.2 | SGP/SMOS/E7 - Reprocess: Wind direction incorrect | sgp1smosE7.a0, sgp30smosE7.a1 |
D970507.1 | SGP/SMOS/E7 - Humidity data drifted out of tolerance | sgp1smosE7.a0, sgp30smosE7.a1 |
D970610.1 | SGP/SMOS/E9 - Erroneous SMOS E9 humidity data | sgp1440smosE9.a0, sgp1smosE9.a0, sgp30smosE9.a1 |
D971006.1 | SGP/SMOS/E8 - Reprocess: Incorrect wind directions from E8 SMOS | sgp1smosE8.a0, sgp30smosE8.a1 |
D971112.10 | SGP/SMOS/E8 - Questionable E8 SMOS rain data | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
D971112.4 | SGP/SMOS/E4 - Incorrect rain data from E4 SMOS | sgp1smosE4.a0, sgp30smosE4.a1 |
D971112.6 | SGP/SMOS/E5 - Questionable E5 SMOS rain data | sgp1smosE5.a0, sgp30smosE5.a1 |
D980401.6 | SGP/SMOS/E24 - Incorrect RH data from E24 SMOS | sgp1440smosE24.a0, sgp1smosE24.00, sgp1smosE24.a0, sgp30smosE24.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/16/1997 | 0000 | 10/29/1997 | 1815 |
Subject: | SGP/SMOS/E8 - Incorrect E8 SMOS rain data |
DataStreams: | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | The E8 SMOS rain gauge pulse counter was found to be non-operational during the 16 SEP 97 PM. It was repaired by replacing the CR10 wiring harness on 29 OCT 97 at 1815 GMT. |
Measurements: | sgp1smosE8.a0:
sgp1smosE8.00:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/18/1996 | 1325 | 04/18/1996 | 1525 |
10/30/1996 | 2145 | 10/30/1996 | 2230 |
04/30/1997 | 1430 | 04/30/1997 | 1700 |
10/29/1997 | 1442 | 10/29/1997 | 1600 |
04/29/1998 | 1350 | 04/29/1998 | 1530 |
11/24/1998 | 1355 | 11/24/1998 | 1555 |
04/13/1999 | 1930 | 04/13/1999 | 2030 |
09/29/1999 | 1255 | 09/29/1999 | 1455 |
04/25/2000 | 1750 | 04/25/2000 | 1950 |
10/24/2000 | 1930 | 10/24/2000 | 2030 |
Subject: | SGP/SMOS/E1 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE1.a0, sgp1smosE1.a0, sgp30smosE1.a1 |
Description: | During the time periods specified, the SMOS.E1 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1440smosE1.a0:
sgp30smosE1.a1:
sgp1smosE1.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/1996 | 2107 | 05/01/1996 | 2200 |
11/14/1996 | 1501 | 11/14/1996 | 1606 |
04/16/1997 | 2030 | 04/16/1997 | 2230 |
10/15/1997 | 1700 | 10/15/1997 | 1740 |
05/13/1998 | 1505 | 05/13/1998 | 1730 |
11/11/1998 | 2217 | 11/11/1998 | 2243 |
03/31/1999 | 1830 | 03/31/1999 | 2100 |
05/12/1999 | 1628 | 05/12/1999 | 1700 |
12/08/1999 | 1550 | 12/08/1999 | 1700 |
05/10/2000 | 1620 | 05/10/2000 | 1711 |
09/27/2000 | 1700 | 09/27/2000 | 1800 |
Subject: | SGP/SMOS/E3 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE3.a0, sgp1smosE3.a0, sgp30smosE3.a1 |
Description: | During the time periods specified, the SMOS.E3 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE3.a0:
sgp30smosE3.a1:
sgp1440smosE3.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/03/1995 | 1900 | 10/03/1995 | 2100 |
04/18/1996 | 1945 | 04/18/1996 | 2145 |
10/31/1996 | 1635 | 10/31/1996 | 1752 |
04/30/1997 | 1656 | 04/30/1997 | 1856 |
10/30/1997 | 1500 | 10/30/1997 | 1700 |
04/29/1998 | 1801 | 04/29/1998 | 2001 |
11/24/1998 | 1815 | 11/24/1998 | 1850 |
04/14/1999 | 1545 | 04/14/1999 | 1630 |
09/29/1999 | 1800 | 09/29/1999 | 1820 |
04/26/2000 | 1430 | 04/26/2000 | 1523 |
11/08/2000 | 1548 | 11/08/2000 | 1615 |
Subject: | SGP/SMOS/E4 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE4.a0, sgp1smosE4.a0, sgp30smosE4.a1 |
Description: | During the time periods specified, the SMOS.E4 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE4.a0:
sgp30smosE4.a1:
sgp1440smosE4.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/31/1996 | 2105 | 10/31/1996 | 2155 |
05/01/1997 | 1530 | 05/01/1997 | 1730 |
10/30/1997 | 1445 | 10/30/1997 | 1530 |
04/30/1998 | 1426 | 04/30/1998 | 1524 |
11/25/1998 | 1645 | 11/25/1998 | 1725 |
04/14/1999 | 1823 | 04/14/1999 | 1930 |
09/30/1999 | 1653 | 09/30/1999 | 1822 |
04/26/2000 | 1725 | 04/26/2000 | 1800 |
11/08/2000 | 1940 | 11/08/2000 | 2000 |
Subject: | SGP/SMOS/E5 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE5.a0, sgp1smosE5.a0, sgp30smosE5.a1 |
Description: | During the time periods specified, the SMOS.E5 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1440smosE5.a0:
sgp30smosE5.a1:
sgp1smosE5.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/1996 | 1614 | 05/01/1996 | 1710 |
11/14/1996 | 2010 | 11/14/1996 | 2120 |
04/29/1997 | 1745 | 04/29/1997 | 1945 |
10/14/1997 | 1850 | 10/14/1997 | 1910 |
05/13/1998 | 1500 | 05/13/1998 | 1530 |
11/12/1998 | 1500 | 11/12/1998 | 1730 |
04/01/1999 | 1510 | 04/01/1999 | 1520 |
05/12/1999 | 2052 | 05/12/1999 | 2120 |
12/08/1999 | 1939 | 12/08/1999 | 2015 |
05/10/2000 | 1820 | 05/10/2000 | 2020 |
09/28/2000 | 1420 | 09/28/2000 | 1530 |
Subject: | SGP/SMOS/E6 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE6.a0, sgp1smosE6.a0, sgp30smosE6.a1 |
Description: | During the time periods specified, the SMOS.E6 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1440smosE6.a0:
sgp1smosE6.a0:
sgp30smosE6.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/04/1995 | 1553 | 10/04/1995 | 1654 |
05/02/1996 | 1521 | 05/02/1996 | 1605 |
11/13/1996 | 1645 | 11/13/1996 | 1810 |
04/16/1997 | 1415 | 04/16/1997 | 1523 |
10/16/1997 | 1530 | 10/16/1997 | 1600 |
05/12/1998 | 2100 | 05/12/1998 | 2130 |
11/11/1998 | 1400 | 11/11/1998 | 1800 |
03/30/1999 | 1845 | 03/30/1999 | 1940 |
12/07/1999 | 2009 | 12/07/1999 | 2100 |
05/09/2000 | 1800 | 05/09/2000 | 1845 |
09/26/2000 | 2000 | 09/26/2000 | 2100 |
Subject: | SGP/SMOS/E7 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE7.a0, sgp1smosE7.a0, sgp30smosE7.a1 |
Description: | During the time periods specified, the SMOS.E7 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1440smosE7.a0:
sgp30smosE7.a1:
sgp1smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/15/1994 | 1525 | 06/15/1994 | 1725 |
11/16/1994 | 1458 | 11/16/1994 | 1658 |
04/19/1995 | 1717 | 04/19/1995 | 1818 |
10/02/1995 | 1940 | 10/02/1995 | 2215 |
04/17/1996 | 1400 | 04/17/1996 | 1730 |
10/30/1996 | 1550 | 10/30/1996 | 1730 |
04/29/1997 | 1930 | 04/29/1997 | 2000 |
10/28/1997 | 2000 | 10/28/1997 | 2300 |
10/29/1997 | 1815 | 10/29/1997 | 1910 |
04/28/1998 | 2035 | 04/28/1998 | 2110 |
11/23/1998 | 1900 | 11/23/1998 | 1940 |
04/27/1999 | 1735 | 04/27/1999 | 2300 |
09/28/1999 | 1910 | 09/28/1999 | 1930 |
04/25/2000 | 1636 | 04/25/2000 | 1707 |
10/24/2000 | 1648 | 10/24/2000 | 1800 |
Subject: | SGP/SMOS/E8 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE8.a0, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | During the time periods specified, the SMOS.E8 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE8.a0:
sgp1440smosE8.a0:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/13/1994 | 1609 | 06/13/1994 | 1809 |
11/14/1994 | 1741 | 11/14/1994 | 1922 |
04/18/1995 | 1414 | 04/18/1995 | 1549 |
10/05/1995 | 1558 | 10/05/1995 | 1704 |
04/30/1996 | 1630 | 04/30/1996 | 1810 |
11/15/1996 | 1645 | 11/15/1996 | 1725 |
11/27/1996 | 1745 | 11/27/1996 | 1805 |
05/01/1997 | 1543 | 05/01/1997 | 2341 |
10/16/1997 | 1940 | 10/16/1997 | 2230 |
05/14/1998 | 1633 | 05/14/1998 | 1729 |
11/12/1998 | 2052 | 11/12/1998 | 2123 |
04/01/1999 | 1900 | 04/01/1999 | 1930 |
05/13/1999 | 1500 | 05/13/1999 | 1600 |
12/09/1999 | 1554 | 12/09/1999 | 1641 |
05/11/2000 | 1258 | 05/11/2000 | 1458 |
09/26/2000 | 1600 | 09/26/2000 | 1649 |
Subject: | SGP/SMOS/E9 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE9.a0, sgp1smosE9.a0, sgp30smosE9.a1 |
Description: | During the time periods specified, the SMOS.E9 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1440smosE9.a0:
sgp1smosE9.a0:
sgp30smosE9.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/14/1994 | 1445 | 06/14/1994 | 1645 |
11/21/1994 | 1632 | 11/21/1994 | 1832 |
04/24/1995 | 1640 | 04/24/1995 | 1900 |
10/10/1995 | 1600 | 10/10/1995 | 2050 |
04/23/1996 | 1724 | 04/23/1996 | 1830 |
11/05/1996 | 1645 | 11/05/1996 | 1930 |
04/22/1997 | 1528 | 04/22/1997 | 1800 |
05/05/1998 | 1412 | 05/05/1998 | 1612 |
12/03/1998 | 1640 | 12/03/1998 | 1655 |
04/20/1999 | 1500 | 04/20/1999 | 1755 |
10/05/1999 | 1545 | 10/05/1999 | 1615 |
04/18/2000 | 1500 | 04/18/2000 | 1540 |
10/17/2000 | 1515 | 10/17/2000 | 1705 |
Subject: | SGP/SMOS/E15 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE15.a0, sgp1smosE15.a0, sgp30smosE15.a1 |
Description: | During the time periods specified, the SMOS.E15 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE15.a0:
sgp1440smosE15.a0:
sgp30smosE15.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/09/1994 | 1624 | 06/09/1994 | 1824 |
11/25/1994 | 1622 | 11/25/1994 | 1822 |
04/27/1995 | 1437 | 04/27/1995 | 1637 |
10/13/1995 | 1300 | 10/13/1995 | 1520 |
04/10/1996 | 1629 | 04/10/1996 | 1900 |
10/23/1996 | 1705 | 10/23/1996 | 1905 |
04/09/1997 | 1850 | 04/09/1997 | 2300 |
05/21/1997 | 1420 | 05/21/1997 | 1620 |
10/22/1997 | 1255 | 10/22/1997 | 1455 |
05/20/1998 | 1300 | 05/20/1998 | 1900 |
11/20/1998 | 1739 | 11/20/1998 | 1939 |
03/24/1999 | 1409 | 03/24/1999 | 1609 |
04/07/1999 | 1515 | 04/07/1999 | 1620 |
12/15/1999 | 2011 | 12/15/1999 | 2045 |
05/17/2000 | 1855 | 05/17/2000 | 1940 |
10/04/2000 | 1922 | 10/04/2000 | 2000 |
Subject: | SGP/SMOS/E20 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE20.a0, sgp1smosE20.a0, sgp30smosE20.a1 |
Description: | During the time periods specified, the SMOS.E20 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE20.a0:
sgp30smosE20.a1:
sgp1440smosE20.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/17/1995 | 1422 | 10/17/1995 | 1622 |
04/16/1996 | 2130 | 04/16/1996 | 2330 |
10/29/1996 | 1700 | 10/29/1996 | 1810 |
04/29/1997 | 1550 | 04/29/1997 | 1830 |
10/28/1997 | 1645 | 10/28/1997 | 1900 |
05/05/1998 | 1900 | 05/05/1998 | 1945 |
12/03/1998 | 1940 | 12/03/1998 | 1955 |
04/20/1999 | 1830 | 04/20/1999 | 2215 |
10/05/1999 | 1843 | 10/05/1999 | 1935 |
04/18/2000 | 1820 | 04/18/2000 | 1855 |
10/17/2000 | 1858 | 10/17/2000 | 2000 |
Subject: | SGP/SMOS/E11 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE11.a0, sgp1smosE11.a0, sgp30smosE11.a1 |
Description: | During the time periods specified, the SMOS.E11 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE11.a0:
sgp1440smosE11.a0:
sgp30smosE11.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/17/1994 | 1415 | 06/17/1994 | 1615 |
11/18/1994 | 2000 | 11/18/1994 | 2100 |
05/05/1995 | 1942 | 05/05/1995 | 2030 |
10/06/1995 | 1800 | 10/06/1995 | 1858 |
05/03/1996 | 1850 | 05/03/1996 | 2100 |
11/18/1996 | 2130 | 11/19/1996 | 0030 |
04/20/1997 | 0000 | 04/20/1997 | 2359 |
10/10/1997 | 1515 | 10/10/1997 | 1845 |
05/07/1998 | 2030 | 05/07/1998 | 2115 |
12/04/1998 | 1600 | 12/04/1998 | 1621 |
04/09/1999 | 1730 | 04/09/1999 | 2100 |
10/07/1999 | 1900 | 10/07/1999 | 1945 |
04/20/2000 | 1727 | 04/20/2000 | 1927 |
05/04/2000 | 1844 | 05/04/2000 | 1910 |
10/19/2000 | 1915 | 10/19/2000 | 2020 |
Subject: | SGP/SMOS/E13 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
Description: | During the time periods specified, the SMOS.E13 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1440smosE13.a0:
sgp30smosE13.a1:
sgp1smosE13.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/12/1995 | 1355 | 10/12/1995 | 1500 |
04/24/1996 | 1630 | 04/24/1996 | 1830 |
11/07/1996 | 1555 | 11/07/1996 | 1645 |
04/23/1997 | 1930 | 04/23/1997 | 2130 |
10/21/1997 | 1600 | 10/21/1997 | 2030 |
05/19/1998 | 1930 | 05/19/1998 | 2200 |
11/19/1998 | 1445 | 11/19/1998 | 1620 |
03/23/1999 | 2100 | 03/23/1999 | 2300 |
12/16/1999 | 1655 | 12/16/1999 | 1855 |
03/07/2000 | 1700 | 03/07/2000 | 1855 |
05/18/2000 | 1550 | 05/18/2000 | 1700 |
10/05/2000 | 1648 | 10/05/2000 | 1725 |
Subject: | SGP/SMOS/E24 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE24.a0, sgp1smosE24.a0, sgp30smosE24.a1 |
Description: | During the time periods specified, the SMOS.E24 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp30smosE24.a1:
sgp1smosE24.a0:
sgp1440smosE24.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/09/1997 | 1830 | 04/09/1997 | 2030 |
05/21/1997 | 1645 | 05/21/1997 | 1855 |
10/22/1997 | 1645 | 10/22/1997 | 1930 |
05/20/1998 | 1830 | 05/20/1998 | 2000 |
01/13/1999 | 1900 | 01/13/1999 | 2100 |
03/25/1999 | 1620 | 03/25/1999 | 1740 |
12/15/1999 | 1607 | 12/15/1999 | 1645 |
05/17/2000 | 1630 | 05/17/2000 | 1733 |
10/04/2000 | 1645 | 10/04/2000 | 1735 |
Subject: | SGP/SMOS/E25 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE25.a0, sgp1smosE25.a0, sgp30smosE25.a1 |
Description: | During the time periods specified, the SMOS.E25 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1smosE25.a0:
sgp30smosE25.a1:
sgp1440smosE25.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/1996 | 0000 | 01/30/1997 | 1930 |
Subject: | SGP/SMOS/E13 - Questionable data |
DataStreams: | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
Description: | The values of relative humidity reported by the SMOS at E13 between 18 NOV 96 and 1930 GMT on 30 JAN 97 are too high. Saturation values of 104% to 105% have been reported during this period. A 6-month Verification Check was made on 18 NOV 96 and the SMOS probe did not agree with the reference at that time. The SMOS probe was finally replaced on 30 JAN 97. Data reported since that time appears reasonable. |
Measurements: | sgp1440smosE13.a0:
sgp30smosE13.a1:
sgp1smosE13.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/29/1996 | 0000 | 02/11/1997 | 1930 |
Subject: | SGP/SMOS/E24 - RH values exceeding the specified maximum value |
DataStreams: | sgp1440smosE24.a0, sgp1smosE24.a0, sgp30smosE24.a1 |
Description: | Starting on 29 OCT 96, the SMOS at E24 started reporting RH values exceeding the specified maximum value. Lower values of RH may be within tolerances. On 7 NOV 96 during the 6-month Sensor Verifications, the T/RH sensor reported a value of 31% RH that agreed with the reference within specified tolerances. The probe continued to report values which exceeded 104% and was replaced on 11 FEB 97 at 1930 GMT. Reported values since then appear to be within tolerances. |
Measurements: | sgp30smosE24.a1:
sgp1smosE24.a0:
sgp1440smosE24.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/1997 | 0730 | 02/22/1997 | 1230 |
Subject: | SGP/SMOS/E13 - T/RH Probe Malfunction |
DataStreams: | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
Description: | When the SMOS E13 T/RH probe was replaced on 30 JAN 97, it was not adequately sealed to prevent rain infiltration. During a rain, which fell between 20 FEB 97 at 0730 GMT and 22 FEB 97 at 1230 GMT, the RH probe malfunctioned apparently due to becoming wet. |
Measurements: | sgp1440smosE13.a0:
sgp30smosE13.a1:
sgp1smosE13.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/26/1997 | 1530 | 02/26/1997 | 2130 |
Subject: | SGP/SMOS/E13 - T/RH Probe Malfunction |
DataStreams: | sgp1smosE13.a0, sgp30smosE13.a1 |
Description: | When the SMOS E13 T/RH probe was replaced on 30 JAN 97, it was not adequately sealed to prevent rain infiltration. During a rain, which fell on 26 FEB 97 between 1530 and 2130 GMT, the RH probe malfunctioned apparently due to becoming wet. Bad RH data were reported between 1530-1700 GMT and again between 2000-2130 GMT. |
Measurements: | sgp30smosE13.a1:
sgp1smosE13.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/27/1997 | 0230 | 02/27/1997 | 1630 |
Subject: | SGP/SMOS/E13 - T/RH Probe Malfunction |
DataStreams: | sgp1440smosE13.a0, sgp1smosE13.a0, sgp30smosE13.a1 |
Description: | When the SMOS E13 T/RH probe was replaced on 30 JAN 97, it was not adequately sealed to prevent rain infiltration. During a rain, which fell on 27 FEB 97 between 0230 and 1630 GMT, the RH probe malfunctioned apparently due to becoming wet. |
Measurements: | sgp1440smosE13.a0:
sgp30smosE13.a1:
sgp1smosE13.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/1997 | 2130 | 03/20/1997 | 1600 |
Subject: | SGP/SMOS/E7 - Reprocess: Wind direction incorrect |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1 |
Description: | The 10m tower at E7 fell on 20 FEB 97 some time after 2130 GMT. It was returned to service on 13 MAR 97 at 0600 GMT, but the wind monitor was incorrectly installed resulting in wind directions being 180 deg out until it was re-oriented on 20 MAR 97 at 1600 GMT. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/04/1996 | 0000 | 04/16/1997 | 1430 |
Subject: | SGP/SMOS/E7 - Humidity data drifted out of tolerance |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1 |
Description: | The humidity data reported by the Elk Falls (E7) SMOS drifted out of tolerance starting on approximately 4 OCT 96. The RH probe started reporting values exceeding 104% RH. The SMOS underwent a 6-month verification check on 13 NOV 96, but the reference RH sensor was not operating properly at the time. At the mentor's request, the T/RH probe was replaced on 4 FEB 97, but the replacement probe was not operating within specifications. Due to lack of calibrated spare probes, the bad replacement T/RH probe was not replaced until 16 APR 97. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/25/1997 | 0630 | 05/28/1997 | 2000 |
Subject: | SGP/SMOS/E9 - Erroneous SMOS E9 humidity data |
DataStreams: | sgp1440smosE9.a0, sgp1smosE9.a0, sgp30smosE9.a1 |
Description: | SMOS E9 humidity data were erroneous between 0630 on 25 MAY 97 and 2000 GMT on 28 MAY 97. The cause is unknown. Site Ops personnel visited the site on 29 MAY 97 and found no problems. |
Measurements: | sgp1440smosE9.a0:
sgp1smosE9.a0:
sgp30smosE9.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/1997 | 2000 | 09/30/1997 | 2100 |
Subject: | SGP/SMOS/E8 - Reprocess: Incorrect wind directions from E8 SMOS |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | When the Wind Monitor was changed at E8 for scheduled PM, the replacement sensor was incorrectly wired to the data logger. It did not effect the wind speed readings, but wind directions had E and W reversed. Thus winds from 15 deg were reported as being from 345 deg, and vice-versa, and winds from 165 deg were reported as being from 195 degrees, and vice-versa. |
Measurements: | sgp1smosE8.a0:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/02/1997 | 0000 | 09/16/1997 | 0000 |
Subject: | SGP/SMOS/E8 - Questionable E8 SMOS rain data |
DataStreams: | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | The E8 SMOS rain gauge pulse counter was found to be non-operational during the 16 SEP 97 PM. It was repaired by replacing the CR10 wiring harness on 29 OCT 97 at 1815 GMT. |
Measurements: | sgp1smosE8.a0:
sgp1smosE8.00:
sgp30smosE8.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/1997 | 0000 | 10/30/1997 | 1657 |
Subject: | SGP/SMOS/E4 - Incorrect rain data from E4 SMOS |
DataStreams: | sgp1smosE4.a0, sgp30smosE4.a1 |
Description: | The rain gauge funnel was found to be clogged during 30 OCT 97 PM. It was cleared at 1657 GMT. No clog was present during previous PM on 15 OCT 97. Date and time that clog occurred is somewhere between 15 and 30 OCT 97. |
Measurements: | sgp1smosE4.a0:
sgp30smosE4.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/16/1997 | 0000 | 10/30/1997 | 2130 |
Subject: | SGP/SMOS/E5 - Questionable E5 SMOS rain data |
DataStreams: | sgp1smosE5.a0, sgp30smosE5.a1 |
Description: | During the 30 OCT 97 PM the E5 SMOS rain gauge was found to be clogged. It was cleated at 2130 GMT. No clog was present at the 16 OCT 97 PM. |
Measurements: | sgp30smosE5.a1:
sgp1smosE5.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/1997 | 0000 | 03/10/1998 | 1830 |
Subject: | SGP/SMOS/E24 - Incorrect RH data from E24 SMOS |
DataStreams: | sgp1440smosE24.a0, sgp1smosE24.00, sgp1smosE24.a0, sgp30smosE24.a1 |
Description: | The output from the relative humidity probe on E24 SMOS drifted low by as much as 5% when RH exceeded 80% by 15 OCT 97. The probe was replaced on 10 FEB 98 at 1900 GMT. The replacement probe reported values approximately 10% too high when RH exceeded 90%. That probe was replaced at 1830 GMT on 10 MAR 98. |
Measurements: | sgp30smosE24.a1:
sgp1smosE24.a0:
sgp1smosE24.00:
sgp1440smosE24.a0:
|