DQR ID | Subject | Data Streams Affected |
---|
D010403.10 | SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D010403.12 | SGP/EBBR/E13 - E13 Data Missing | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D010403.13 | SGP/EBBR/E13 - E13 Data Missing | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D010403.17 | SGP/EBBR/E13 - E13 EBBR All Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D010403.18 | SGP/EBBR/E13 - E13 EBBR All Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D010403.19 | SGP/EBBR/E13 - E13 EBBR All Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D010403.20 | SGP/EBBR/E13 - E13 EBBR All Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D010403.7 | SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D010403.8 | SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D010403.9 | SGP/EBBR/E13 - E13 EBBR Flux Data Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D010412.1 | SGP/EBBR/E13 - E13 EBBR Soil Temperature #4 Suspect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D010413.1 | SGP/EBBR/E13 - E13 EBBR Wind Direction Iced | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D010413.2 | SGP/EBBR/E13 - E13 EBBR Soil Heat Flow #4 Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D010605.5 | SGP EBBR E13 - E13 EBBR Soil T #4 Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D011127.27 | SGP EBBR E13 - E13 EBBR Data Incorrect During 6 Month Checks | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020129.5 | SGP EBBR E13 - E13 EBBR Left Air Temperature Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020129.7 | SGP EBBR E13 - E13 EBBR Left Air Temperature Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0 |
D020129.8 | SGP/EBBR/E13 - Reprocess: E13 EBBR Soil Temperature #4 Incorrect | sgp15ebbrE13.a1, sgp30ebbrE13.a1 |
D020129.9 | SGP/EBBR/E13 - Reprocess: E13 EBBR Soil Temperature #4 Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1 |
D021113.4 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE12.a1, sgp30ebbrE13.a1, sgp30ebbrE15.a1, sgp30ebbrE20.a1, sgp30ebbrE22.a1, sgp30ebbrE26.a1, sgp30ebbrE4.a1, sgp30ebbrE7.a1, sgp30ebbrE8.a1, sgp30ebbrE9.a1 |
Subject: | SGP/EBBR/E13 - E13 Data Missing |
DataStreams: | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0
|
Description: | Data was missing during battery dropout; solar panel regulator not working. |
Measurements: | sgp5ebbrE13.a0: - Time offset of tweaks from base_time(time_offset)
- Dummy altitude for Zeb(alt)
- Retrieved pressure profile(pres)
- bottom air temperature(tair_bot)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- lat(lat)
- bottom vapor pressure(vp_bot)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- Temperature of the top humidity chamber(thum_top)
- Bottom humidity(hum_bot)
- Top humidity(hum_top)
- scalar wind speed(wind_s)
- lon(lon)
- wind direction (relative to true north)(wind_d)
- net radiation(q)
- Home signal(home)
- Temperature of bottom humidity sensor chamber(thum_bot)
- top air temperature(tair_top)
- Reference Thermistor Temperature(tref)
- base time(base_time)
sgp15ebbrE13.a1: - Soil temperature 1(rr_ts1)
- Dummy altitude for Zeb(alt)
- Soil heat flow 3(mv_hft3)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Soil temperature 2(rr_ts2)
- Soil temperature 3(rr_ts3)
- lon(lon)
- Soil moisture 3(r_sm3)
- Soil moisture 2(r_sm2)
- Soil temperature 4(rr_ts4)
- Soil heat flow 2(mv_hft2)
- Right air temperature(tair_r)
- Atmospheric pressure(mv_pres)
- Battery(bat)
- lat(lat)
- Soil heat flow 5(mv_hft5)
- Soil temperature 5(rr_ts5)
- Left relative humidity(mv_hum_l)
- Reference temperature(rr_tref)
- Time offset of tweaks from base_time(time_offset)
- base time(base_time)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- scalar wind speed(wind_s)
- Soil heat flow 1(mv_hft1)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 4(mv_hft4)
- Signature(signature)
- Left air temperature(tair_l)
- Soil moisture 5(r_sm5)
- Right relative humidity(mv_hum_r)
- Net radiation(mv_q)
- Home signal(mv_home)
- Soil moisture 4(r_sm4)
sgp30ebbrE13.a1: - soil heat flow, site 1(g1)
- Reference Thermistor Temperature(tref)
- 0-5 cm integrated soil temperature, site 2(ts2)
- latent heat flux(e)
- Temperature of bottom humidity sensor chamber(thum_bot)
- 5 cm soil heat flow, site 3(shf3)
- average surface soil heat flow(ave_shf)
- Bottom humidity(hum_bot)
- bottom air temperature(tair_bot)
- soil heat flow, site 5(g5)
- lat(lat)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- 5 cm soil heat flow, site 4(shf4)
- soil heat flow, site 3(g3)
- Soil heat capacity 1(cs1)
- Exchange mechanism position indicator (0 to 15 min)(home_15)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- 0-5 cm integrated soil temperature, site 5(ts5)
- net radiation(q)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Temperature of the top humidity chamber(thum_top)
- Dummy altitude for Zeb(alt)
- soil heat flow, site 2(g2)
- top air temperature(tair_top)
- 0-5 cm integrated soil temperature, site 2(ts1)
- volumetric soil moisture, site 5(sm5)
- Soil heat capacity 3(cs3)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- Exchange mechanism position indicator (15 to 30 min)(home_30)
- volumetric soil moisture, site 4(sm4)
- Soil heat capacity 4(cs4)
- Time offset of tweaks from base_time(time_offset)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Retrieved pressure profile(pres)
- h(h)
- 0-5 cm change in soil heat storage with time, site 2(ces2)
- base time(base_time)
- 0-5 cm integrated soil temperature, site 4(ts4)
- volumetric soil moisture, site 3(sm3)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- volumetric soil moisture, site 2(sm2)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- scalar wind speed(wind_s)
- 5 cm soil heat flow, site 1(shf1)
- volumetric soil moisture, site 1(sm1)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- 5 cm soil heat flow, site 2(shf2)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- lon(lon)
- bottom vapor pressure(vp_bot)
- Top humidity(hum_top)
- soil heat flow, site 4(g4)
|
Subject: | SGP/EBBR/E13 - E13 Data Missing |
DataStreams: | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0
|
Description: | Data was missing during battery dropout; solar panel regulator not working. |
Measurements: | sgp5ebbrE13.a0: - Time offset of tweaks from base_time(time_offset)
- Dummy altitude for Zeb(alt)
- Retrieved pressure profile(pres)
- bottom air temperature(tair_bot)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- lat(lat)
- bottom vapor pressure(vp_bot)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- Temperature of the top humidity chamber(thum_top)
- Bottom humidity(hum_bot)
- Top humidity(hum_top)
- scalar wind speed(wind_s)
- lon(lon)
- wind direction (relative to true north)(wind_d)
- net radiation(q)
- Home signal(home)
- Temperature of bottom humidity sensor chamber(thum_bot)
- top air temperature(tair_top)
- Reference Thermistor Temperature(tref)
- base time(base_time)
sgp15ebbrE13.a1: - Soil temperature 1(rr_ts1)
- Dummy altitude for Zeb(alt)
- Soil heat flow 3(mv_hft3)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Soil temperature 2(rr_ts2)
- Soil temperature 3(rr_ts3)
- lon(lon)
- Soil moisture 3(r_sm3)
- Soil moisture 2(r_sm2)
- Soil temperature 4(rr_ts4)
- Soil heat flow 2(mv_hft2)
- Right air temperature(tair_r)
- Atmospheric pressure(mv_pres)
- Battery(bat)
- lat(lat)
- Soil heat flow 5(mv_hft5)
- Soil temperature 5(rr_ts5)
- Left relative humidity(mv_hum_l)
- Reference temperature(rr_tref)
- Time offset of tweaks from base_time(time_offset)
- base time(base_time)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- scalar wind speed(wind_s)
- Soil heat flow 1(mv_hft1)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 4(mv_hft4)
- Signature(signature)
- Left air temperature(tair_l)
- Soil moisture 5(r_sm5)
- Right relative humidity(mv_hum_r)
- Net radiation(mv_q)
- Home signal(mv_home)
- Soil moisture 4(r_sm4)
sgp30ebbrE13.a1: - soil heat flow, site 1(g1)
- Reference Thermistor Temperature(tref)
- 0-5 cm integrated soil temperature, site 2(ts2)
- latent heat flux(e)
- Temperature of bottom humidity sensor chamber(thum_bot)
- 5 cm soil heat flow, site 3(shf3)
- average surface soil heat flow(ave_shf)
- Bottom humidity(hum_bot)
- bottom air temperature(tair_bot)
- soil heat flow, site 5(g5)
- lat(lat)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- 5 cm soil heat flow, site 4(shf4)
- soil heat flow, site 3(g3)
- Soil heat capacity 1(cs1)
- Exchange mechanism position indicator (0 to 15 min)(home_15)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- 0-5 cm integrated soil temperature, site 5(ts5)
- net radiation(q)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Temperature of the top humidity chamber(thum_top)
- Dummy altitude for Zeb(alt)
- soil heat flow, site 2(g2)
- top air temperature(tair_top)
- 0-5 cm integrated soil temperature, site 2(ts1)
- volumetric soil moisture, site 5(sm5)
- Soil heat capacity 3(cs3)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- Exchange mechanism position indicator (15 to 30 min)(home_30)
- volumetric soil moisture, site 4(sm4)
- Soil heat capacity 4(cs4)
- Time offset of tweaks from base_time(time_offset)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Retrieved pressure profile(pres)
- h(h)
- 0-5 cm change in soil heat storage with time, site 2(ces2)
- base time(base_time)
- 0-5 cm integrated soil temperature, site 4(ts4)
- volumetric soil moisture, site 3(sm3)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- volumetric soil moisture, site 2(sm2)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- scalar wind speed(wind_s)
- 5 cm soil heat flow, site 1(shf1)
- volumetric soil moisture, site 1(sm1)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- 5 cm soil heat flow, site 2(shf2)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- lon(lon)
- bottom vapor pressure(vp_bot)
- Top humidity(hum_top)
- soil heat flow, site 4(g4)
|
Subject: | SGP/EBBR/E13 - E13 EBBR All Data Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0
|
Description: | Low battery voltage caused all data to be incorrect. |
Measurements: | sgp5ebbrE13.a0: - Retrieved pressure profile(pres)
- bottom air temperature(tair_bot)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- bottom vapor pressure(vp_bot)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- Temperature of the top humidity chamber(thum_top)
- Bottom humidity(hum_bot)
- Top humidity(hum_top)
- scalar wind speed(wind_s)
- wind direction (relative to true north)(wind_d)
- net radiation(q)
- Home signal(home)
- Temperature of bottom humidity sensor chamber(thum_bot)
- top air temperature(tair_top)
- Reference Thermistor Temperature(tref)
sgp15ebbrE13.a1: - Soil temperature 1(rr_ts1)
- Soil heat flow 3(mv_hft3)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Soil temperature 2(rr_ts2)
- Soil temperature 3(rr_ts3)
- Soil moisture 3(r_sm3)
- Soil moisture 2(r_sm2)
- Soil temperature 4(rr_ts4)
- Soil heat flow 2(mv_hft2)
- Right air temperature(tair_r)
- Atmospheric pressure(mv_pres)
- Soil heat flow 5(mv_hft5)
- Soil temperature 5(rr_ts5)
- Left relative humidity(mv_hum_l)
- Reference temperature(rr_tref)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- scalar wind speed(wind_s)
- Soil heat flow 1(mv_hft1)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 4(mv_hft4)
- Left air temperature(tair_l)
- Soil moisture 5(r_sm5)
- Right relative humidity(mv_hum_r)
- Net radiation(mv_q)
- Home signal(mv_home)
- Soil moisture 4(r_sm4)
sgp30ebbrE13.a1: - soil heat flow, site 1(g1)
- Reference Thermistor Temperature(tref)
- 0-5 cm integrated soil temperature, site 2(ts2)
- latent heat flux(e)
- 5 cm soil heat flow, site 3(shf3)
- Temperature of bottom humidity sensor chamber(thum_bot)
- average surface soil heat flow(ave_shf)
- Bottom humidity(hum_bot)
- bottom air temperature(tair_bot)
- soil heat flow, site 5(g5)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- 5 cm soil heat flow, site 4(shf4)
- soil heat flow, site 3(g3)
- Soil heat capacity 1(cs1)
- Exchange mechanism position indicator (0 to 15 min)(home_15)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- 0-5 cm integrated soil temperature, site 5(ts5)
- net radiation(q)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Temperature of the top humidity chamber(thum_top)
- soil heat flow, site 2(g2)
- top air temperature(tair_top)
- 0-5 cm integrated soil temperature, site 2(ts1)
- volumetric soil moisture, site 5(sm5)
- Soil heat capacity 3(cs3)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- Exchange mechanism position indicator (15 to 30 min)(home_30)
- volumetric soil moisture, site 4(sm4)
- Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Retrieved pressure profile(pres)
- h(h)
- 0-5 cm change in soil heat storage with time, site 2(ces2)
- 0-5 cm integrated soil temperature, site 4(ts4)
- volumetric soil moisture, site 3(sm3)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- volumetric soil moisture, site 2(sm2)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- scalar wind speed(wind_s)
- 5 cm soil heat flow, site 1(shf1)
- volumetric soil moisture, site 1(sm1)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- 5 cm soil heat flow, site 2(shf2)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- bottom vapor pressure(vp_bot)
- Top humidity(hum_top)
- soil heat flow, site 4(g4)
|
Subject: | SGP/EBBR/E13 - E13 EBBR All Data Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0
|
Description: | All data was incorrect for an unknown reason. |
Measurements: | sgp5ebbrE13.a0: - Retrieved pressure profile(pres)
- bottom air temperature(tair_bot)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- bottom vapor pressure(vp_bot)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- Temperature of the top humidity chamber(thum_top)
- Bottom humidity(hum_bot)
- Top humidity(hum_top)
- scalar wind speed(wind_s)
- wind direction (relative to true north)(wind_d)
- net radiation(q)
- Home signal(home)
- Temperature of bottom humidity sensor chamber(thum_bot)
- top air temperature(tair_top)
- Reference Thermistor Temperature(tref)
sgp15ebbrE13.a1: - Soil temperature 1(rr_ts1)
- Soil heat flow 3(mv_hft3)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Soil temperature 2(rr_ts2)
- Soil temperature 3(rr_ts3)
- Soil moisture 3(r_sm3)
- Soil moisture 2(r_sm2)
- Soil temperature 4(rr_ts4)
- Soil heat flow 2(mv_hft2)
- Right air temperature(tair_r)
- Atmospheric pressure(mv_pres)
- Soil heat flow 5(mv_hft5)
- Soil temperature 5(rr_ts5)
- Left relative humidity(mv_hum_l)
- Reference temperature(rr_tref)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- scalar wind speed(wind_s)
- Soil heat flow 1(mv_hft1)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 4(mv_hft4)
- Left air temperature(tair_l)
- Soil moisture 5(r_sm5)
- Right relative humidity(mv_hum_r)
- Net radiation(mv_q)
- Home signal(mv_home)
- Soil moisture 4(r_sm4)
sgp30ebbrE13.a1: - soil heat flow, site 1(g1)
- Reference Thermistor Temperature(tref)
- 0-5 cm integrated soil temperature, site 2(ts2)
- latent heat flux(e)
- 5 cm soil heat flow, site 3(shf3)
- Temperature of bottom humidity sensor chamber(thum_bot)
- average surface soil heat flow(ave_shf)
- Bottom humidity(hum_bot)
- bottom air temperature(tair_bot)
- soil heat flow, site 5(g5)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- 5 cm soil heat flow, site 4(shf4)
- soil heat flow, site 3(g3)
- Soil heat capacity 1(cs1)
- Exchange mechanism position indicator (0 to 15 min)(home_15)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- 0-5 cm integrated soil temperature, site 5(ts5)
- net radiation(q)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Temperature of the top humidity chamber(thum_top)
- soil heat flow, site 2(g2)
- top air temperature(tair_top)
- 0-5 cm integrated soil temperature, site 2(ts1)
- volumetric soil moisture, site 5(sm5)
- Soil heat capacity 3(cs3)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- Exchange mechanism position indicator (15 to 30 min)(home_30)
- volumetric soil moisture, site 4(sm4)
- Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Retrieved pressure profile(pres)
- h(h)
- 0-5 cm change in soil heat storage with time, site 2(ces2)
- 0-5 cm integrated soil temperature, site 4(ts4)
- volumetric soil moisture, site 3(sm3)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- volumetric soil moisture, site 2(sm2)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- scalar wind speed(wind_s)
- 5 cm soil heat flow, site 1(shf1)
- volumetric soil moisture, site 1(sm1)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- 5 cm soil heat flow, site 2(shf2)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- bottom vapor pressure(vp_bot)
- Top humidity(hum_top)
- soil heat flow, site 4(g4)
|
Subject: | SGP/EBBR/E13 - E13 EBBR All Data Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0
|
Description: | Battery voltage was too low. All data was incorrect. |
Measurements: | sgp5ebbrE13.a0: - Retrieved pressure profile(pres)
- bottom air temperature(tair_bot)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- bottom vapor pressure(vp_bot)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- Temperature of the top humidity chamber(thum_top)
- Bottom humidity(hum_bot)
- Top humidity(hum_top)
- scalar wind speed(wind_s)
- wind direction (relative to true north)(wind_d)
- net radiation(q)
- Home signal(home)
- Temperature of bottom humidity sensor chamber(thum_bot)
- top air temperature(tair_top)
- Reference Thermistor Temperature(tref)
sgp15ebbrE13.a1: - Soil temperature 1(rr_ts1)
- Soil heat flow 3(mv_hft3)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Soil temperature 2(rr_ts2)
- Soil temperature 3(rr_ts3)
- Soil moisture 3(r_sm3)
- Soil moisture 2(r_sm2)
- Soil temperature 4(rr_ts4)
- Soil heat flow 2(mv_hft2)
- Right air temperature(tair_r)
- Atmospheric pressure(mv_pres)
- Soil heat flow 5(mv_hft5)
- Soil temperature 5(rr_ts5)
- Left relative humidity(mv_hum_l)
- Reference temperature(rr_tref)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- scalar wind speed(wind_s)
- Soil heat flow 1(mv_hft1)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 4(mv_hft4)
- Left air temperature(tair_l)
- Soil moisture 5(r_sm5)
- Right relative humidity(mv_hum_r)
- Net radiation(mv_q)
- Home signal(mv_home)
- Soil moisture 4(r_sm4)
sgp30ebbrE13.a1: - soil heat flow, site 1(g1)
- Reference Thermistor Temperature(tref)
- 0-5 cm integrated soil temperature, site 2(ts2)
- latent heat flux(e)
- 5 cm soil heat flow, site 3(shf3)
- Temperature of bottom humidity sensor chamber(thum_bot)
- average surface soil heat flow(ave_shf)
- Bottom humidity(hum_bot)
- bottom air temperature(tair_bot)
- soil heat flow, site 5(g5)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- 5 cm soil heat flow, site 4(shf4)
- soil heat flow, site 3(g3)
- Soil heat capacity 1(cs1)
- Exchange mechanism position indicator (0 to 15 min)(home_15)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- 0-5 cm integrated soil temperature, site 5(ts5)
- net radiation(q)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Temperature of the top humidity chamber(thum_top)
- soil heat flow, site 2(g2)
- top air temperature(tair_top)
- 0-5 cm integrated soil temperature, site 2(ts1)
- volumetric soil moisture, site 5(sm5)
- Soil heat capacity 3(cs3)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- Exchange mechanism position indicator (15 to 30 min)(home_30)
- volumetric soil moisture, site 4(sm4)
- Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Retrieved pressure profile(pres)
- h(h)
- 0-5 cm change in soil heat storage with time, site 2(ces2)
- 0-5 cm integrated soil temperature, site 4(ts4)
- volumetric soil moisture, site 3(sm3)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- volumetric soil moisture, site 2(sm2)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- scalar wind speed(wind_s)
- 5 cm soil heat flow, site 1(shf1)
- volumetric soil moisture, site 1(sm1)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- 5 cm soil heat flow, site 2(shf2)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- bottom vapor pressure(vp_bot)
- Top humidity(hum_top)
- soil heat flow, site 4(g4)
|
Subject: | SGP/EBBR/E13 - E13 EBBR All Data Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp30ebbrE13.a1, sgp5ebbrE13.a0
|
Description: | Battery voltage was too low. All data was incorrect. |
Measurements: | sgp5ebbrE13.a0: - Retrieved pressure profile(pres)
- bottom air temperature(tair_bot)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- bottom vapor pressure(vp_bot)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- Temperature of the top humidity chamber(thum_top)
- Bottom humidity(hum_bot)
- Top humidity(hum_top)
- scalar wind speed(wind_s)
- wind direction (relative to true north)(wind_d)
- net radiation(q)
- Home signal(home)
- Temperature of bottom humidity sensor chamber(thum_bot)
- top air temperature(tair_top)
- Reference Thermistor Temperature(tref)
sgp15ebbrE13.a1: - Soil temperature 1(rr_ts1)
- Soil heat flow 3(mv_hft3)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Soil temperature 2(rr_ts2)
- Soil temperature 3(rr_ts3)
- Soil moisture 3(r_sm3)
- Soil moisture 2(r_sm2)
- Soil temperature 4(rr_ts4)
- Soil heat flow 2(mv_hft2)
- Right air temperature(tair_r)
- Atmospheric pressure(mv_pres)
- Soil heat flow 5(mv_hft5)
- Soil temperature 5(rr_ts5)
- Left relative humidity(mv_hum_l)
- Reference temperature(rr_tref)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- scalar wind speed(wind_s)
- Soil heat flow 1(mv_hft1)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 4(mv_hft4)
- Left air temperature(tair_l)
- Soil moisture 5(r_sm5)
- Right relative humidity(mv_hum_r)
- Net radiation(mv_q)
- Home signal(mv_home)
- Soil moisture 4(r_sm4)
sgp30ebbrE13.a1: - soil heat flow, site 1(g1)
- Reference Thermistor Temperature(tref)
- 0-5 cm integrated soil temperature, site 2(ts2)
- latent heat flux(e)
- 5 cm soil heat flow, site 3(shf3)
- Temperature of bottom humidity sensor chamber(thum_bot)
- average surface soil heat flow(ave_shf)
- Bottom humidity(hum_bot)
- bottom air temperature(tair_bot)
- soil heat flow, site 5(g5)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- 5 cm soil heat flow, site 4(shf4)
- soil heat flow, site 3(g3)
- Soil heat capacity 1(cs1)
- Exchange mechanism position indicator (0 to 15 min)(home_15)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- 0-5 cm integrated soil temperature, site 5(ts5)
- net radiation(q)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Temperature of the top humidity chamber(thum_top)
- soil heat flow, site 2(g2)
- top air temperature(tair_top)
- 0-5 cm integrated soil temperature, site 2(ts1)
- volumetric soil moisture, site 5(sm5)
- Soil heat capacity 3(cs3)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- Exchange mechanism position indicator (15 to 30 min)(home_30)
- volumetric soil moisture, site 4(sm4)
- Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Retrieved pressure profile(pres)
- h(h)
- 0-5 cm change in soil heat storage with time, site 2(ces2)
- 0-5 cm integrated soil temperature, site 4(ts4)
- volumetric soil moisture, site 3(sm3)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- volumetric soil moisture, site 2(sm2)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- scalar wind speed(wind_s)
- 5 cm soil heat flow, site 1(shf1)
- volumetric soil moisture, site 1(sm1)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- 5 cm soil heat flow, site 2(shf2)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- bottom vapor pressure(vp_bot)
- Top humidity(hum_top)
- soil heat flow, site 4(g4)
|
Subject: | SGP EBBR E13 - E13 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1
|
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE13.b1: - Soil moisture 2(r_sm2)
- Soil heat flow 2(mv_hft2)
- Soil moisture 3(r_sm3)
- Soil heat flow 3(mv_hft3)
- Soil moisture 4(r_sm4)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Left relative humidity(mv_hum_l)
- Soil moisture 5(r_sm5)
- Reference temperature(rr_tref)
- Net radiation(mv_q)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 1(mv_hft1)
- scalar wind speed(wind_s)
- Soil heat flow 4(mv_hft4)
- Soil temperature 3(rr_ts3)
- Soil temperature 4(rr_ts4)
- Soil temperature 5(rr_ts5)
- Right relative humidity(mv_hum_r)
- Soil heat flow 5(mv_hft5)
- Soil temperature 2(rr_ts2)
- Left air temperature(tair_l)
- Atmospheric pressure(mv_pres)
- Soil temperature 1(rr_ts1)
- Right air temperature(tair_r)
sgp15ebbrE13.a1: - Soil temperature 1(rr_ts1)
- Soil heat flow 3(mv_hft3)
- Temperature of right humidity sensor chamber(rr_thum_r)
- Soil moisture 3(rr_sm3)
- Soil temperature 2(rr_ts2)
- Soil temperature 3(rr_ts3)
- Soil moisture 3(r_sm3)
- Soil moisture 2(r_sm2)
- Soil temperature 4(rr_ts4)
- Soil moisture 4(rr_sm4)
- Soil heat flow 2(mv_hft2)
- Soil moisture 5(rr_sm5)
- Right air temperature(tair_r)
- Soil moisture 2(rr_sm2)
- Atmospheric pressure(mv_pres)
- Soil heat flow 5(mv_hft5)
- Soil moisture 1(rr_sm1)
- Soil temperature 5(rr_ts5)
- Left relative humidity(mv_hum_l)
- Reference temperature(rr_tref)
- Wind direction (relative to true north)(mv_wind_d)
- Soil moisture 1(r_sm1)
- scalar wind speed(wind_s)
- Soil heat flow 1(mv_hft1)
- Temperature of left humidity sensor chamber(rr_thum_l)
- Soil heat flow 4(mv_hft4)
- Left air temperature(tair_l)
- Soil moisture 5(r_sm5)
- Right relative humidity(mv_hum_r)
- Net radiation(mv_q)
- Soil moisture 4(r_sm4)
sgp5ebbrE13.a1: - vector wind speed(res_ws)
- Top humidity(hum_top)
- Reference Thermistor Temperature(tref)
- Retrieved pressure profile(pres)
- scalar wind speed(wind_s)
- Temperature of bottom humidity sensor chamber(thum_bot)
- top vapor pressure(vp_top)
- top air temperature(tair_top)
- net radiation(q)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- bottom air temperature(tair_bot)
- Bottom humidity(hum_bot)
- Temperature of the top humidity chamber(thum_top)
- wind direction (relative to true north)(wind_d)
- bottom vapor pressure(vp_bot)
sgp30ebbrE13.b1: - 0-5 cm change in soil heat storage with time, site 2(ces2)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Soil heat capacity 4(cs4)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- average surface soil heat flow(ave_shf)
- 5 cm soil heat flow, site 4(shf4)
- top vapor pressure(vp_top)
- volumetric soil moisture, site 4(sm4)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- volumetric soil moisture, site 5(sm5)
- soil heat flow, site 3(g3)
- Reference Thermistor Temperature(tref)
- bottom air temperature(tair_bot)
- 0-5 cm integrated soil temperature, site 2(ts1)
- soil heat flow, site 2(g2)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- h(h)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- volumetric soil moisture, site 2(sm2)
- 5 cm soil heat flow, site 1(shf1)
- scalar wind speed(wind_s)
- top air temperature(tair_top)
- Top humidity(hum_top)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- Soil heat capacity 3(cs3)
- 5 cm soil heat flow, site 2(shf2)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- vector wind speed(res_ws)
- Bottom humidity(hum_bot)
- Retrieved pressure profile(pres)
- soil heat flow, site 1(g1)
- soil heat flow, site 4(g4)
- 0-5 cm integrated soil temperature, site 5(ts5)
- Soil heat capacity 2(cs2)
- bottom vapor pressure(vp_bot)
- Temperature of the top humidity chamber(thum_top)
- latent heat flux(e)
- Soil heat capacity 1(cs1)
- net radiation(q)
- volumetric soil moisture, site 3(sm3)
- 5 cm soil heat flow, site 3(shf3)
- volumetric soil moisture, site 1(sm1)
- Temperature of bottom humidity sensor chamber(thum_bot)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- 0-5 cm integrated soil temperature, site 2(ts2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- soil heat flow, site 5(g5)
- 0-5 cm integrated soil temperature, site 4(ts4)
- Soil heat capacity 5(cs5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
sgp30ebbrE13.a1: - soil heat flow, site 1(g1)
- Reference Thermistor Temperature(tref)
- 0-5 cm integrated soil temperature, site 2(ts2)
- latent heat flux(e)
- Temperature of bottom humidity sensor chamber(thum_bot)
- 5 cm soil heat flow, site 3(shf3)
- Bottom humidity(hum_bot)
- average surface soil heat flow(ave_shf)
- bottom air temperature(tair_bot)
- soil heat flow, site 5(g5)
- standard deviation of wind direction (sigma theta)(sigma_wd)
- soil heat flow, site 3(g3)
- 5 cm soil heat flow, site 4(shf4)
- Soil heat capacity 1(cs1)
- 5 cm soil heat flow, site 5(shf5)
- 0-5 cm change in soil heat storage with time, site 5(ces5)
- wind direction (relative to true north)(wind_d)
- 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
- 0-5 cm integrated soil temperature, site 3(ts3)
- 0-5 cm integrated soil temperature, site 5(ts5)
- net radiation(q)
- ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
- Temperature of the top humidity chamber(thum_top)
- soil heat flow, site 2(g2)
- top air temperature(tair_top)
- 0-5 cm integrated soil temperature, site 2(ts1)
- volumetric soil moisture, site 5(sm5)
- Soil heat capacity 3(cs3)
- top vapor pressure(vp_top)
- vector wind speed(res_ws)
- volumetric soil moisture, site 4(sm4)
- Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Retrieved pressure profile(pres)
- h(h)
- 0-5 cm change in soil heat storage with time, site 2(ces2)
- 0-5 cm integrated soil temperature, site 4(ts4)
- volumetric soil moisture, site 3(sm3)
- 0-5 cm change in soil heat storage with time, site 3(ces3)
- 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
- 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
- volumetric soil moisture, site 2(sm2)
- scalar wind speed(wind_s)
- 5 cm soil heat flow, site 1(shf1)
- volumetric soil moisture, site 1(sm1)
- 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
- 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
- 5 cm soil heat flow, site 2(shf2)
- 0-5 cm change in soil heat storage with time, site 2(ces1)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- bottom vapor pressure(vp_bot)
- Top humidity(hum_top)
- soil heat flow, site 4(g4)
|
Subject: | SGP/EBBR/E13 - Reprocess: E13 EBBR Soil Temperature #4 Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1
|
Description: | Soil Temperature #4 was often incorrect, typically too large negative,
during this period, causing other measurements calculated with
it to be incorrect also. This was caused by a bad multiplexor channel,
which was discovered by the vendor during recalibration of the unit
later. |
Measurements: | sgp15ebbrE13.b1: - Soil temperature 4(rr_ts4)
sgp15ebbrE13.a1: - Soil temperature 4(rr_ts4)
sgp30ebbrE13.b1: - 0-5 cm integrated soil temperature, site 4(ts4)
- average surface soil heat flow(ave_shf)
- latent heat flux(e)
- h(h)
- soil heat flow, site 4(g4)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
sgp30ebbrE13.a1: - latent heat flux(e)
- 0-5 cm change in soil heat storage with time, site 4(ces4)
- 0-5 cm integrated soil temperature, site 4(ts4)
- average surface soil heat flow(ave_shf)
- h(h)
- soil heat flow, site 4(g4)
|
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header |
DataStreams: | sgp30ebbrE12.a1, sgp30ebbrE13.a1, sgp30ebbrE15.a1, sgp30ebbrE20.a1, sgp30ebbrE22.a1, sgp30ebbrE26.a1, sgp30ebbrE4.a1, sgp30ebbrE7.a1, sgp30ebbrE8.a1, sgp30ebbrE9.a1
|
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been
incorrect from the beginning of processing the data
into netcdf files. The correct units are MJ/m^3/C.
This does not affect the data quality.
(NOTE: The actual begin date of some of these data streams
is as early as 7/4/93. This DQR applies to all 30m EBBR
data.) |
Measurements: | sgp30ebbrE4.a1: - Soil heat capacity 4(cs4)
- Soil heat capacity 2(cs2)
- Soil heat capacity 5(cs5)
- Soil heat capacity 3(cs3)
- Soil heat capacity 1(cs1)
sgp30ebbrE22.a1: - Soil heat capacity 1(cs1)
- Soil heat capacity 5(cs5)
- Soil heat capacity 4(cs4)
- Soil heat capacity 3(cs3)
- Soil heat capacity 2(cs2)
sgp30ebbrE12.a1: - Soil heat capacity 4(cs4)
- Soil heat capacity 1(cs1)
- Soil heat capacity 2(cs2)
- Soil heat capacity 3(cs3)
- Soil heat capacity 5(cs5)
sgp30ebbrE7.a1: - Soil heat capacity 2(cs2)
- Soil heat capacity 5(cs5)
- Soil heat capacity 3(cs3)
- Soil heat capacity 1(cs1)
- Soil heat capacity 4(cs4)
sgp30ebbrE20.a1: - Soil heat capacity 4(cs4)
- Soil heat capacity 3(cs3)
- Soil heat capacity 2(cs2)
- Soil heat capacity 5(cs5)
- Soil heat capacity 1(cs1)
sgp30ebbrE15.a1: - Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 1(cs1)
- Soil heat capacity 3(cs3)
- Soil heat capacity 2(cs2)
sgp30ebbrE9.a1: - Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 3(cs3)
- Soil heat capacity 2(cs2)
- Soil heat capacity 1(cs1)
sgp30ebbrE26.a1: - Soil heat capacity 5(cs5)
- Soil heat capacity 3(cs3)
- Soil heat capacity 2(cs2)
- Soil heat capacity 1(cs1)
- Soil heat capacity 4(cs4)
sgp30ebbrE8.a1: - Soil heat capacity 1(cs1)
- Soil heat capacity 5(cs5)
- Soil heat capacity 3(cs3)
- Soil heat capacity 2(cs2)
- Soil heat capacity 4(cs4)
sgp30ebbrE13.a1: - Soil heat capacity 3(cs3)
- Soil heat capacity 4(cs4)
- Soil heat capacity 5(cs5)
- Soil heat capacity 2(cs2)
- Soil heat capacity 1(cs1)
|