DQR ID | Subject | Data Streams Affected |
---|---|---|
D070409.1 | TWP/SMET/C1 - Upper winds failure | twpsmet60sC1.b1 |
D071203.1 | TWP/MPL/C1 - Scope Temp is incorrect | twpmplpolC1.b1, twpmplpolavgC1.c1, twpmplpolavgC1.s1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/19/2007 | 0000 | 06/12/2007 | 0406 |
Subject: | TWP/SMET/C1 - Upper winds failure |
DataStreams: | twpsmet60sC1.b1 |
Description: | The upper wind instrument was inoperative resulting in constant wind direction and speed. A failed cable was replaced. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2007 | 0000 | 06/10/2007 | 0400 |
Subject: | TWP/MPL/C1 - Scope Temp is incorrect |
DataStreams: | twpmplpolC1.b1, twpmplpolavgC1.c1, twpmplpolavgC1.s1 |
Description: | Scope temperature is incorrect because the probe failed/was missing. Ignore the scope temperatures and assume the true values are acceptable. |
Measurements: | twpmplpolC1.b1:
twpmplpolavgC1.c1:
twpmplpolavgC1.s1:
|