DQR ID | Subject | Data Streams Affected |
---|---|---|
D000201.2 | SGP/OKM/X1 - Incorrect Station Identifier and Information | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
D000201.3 | SGP/OKM/X1 - Incorrect Station Identifier and Information | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
D000202.2 | SGP/OKM/X1 - Station PRES decommissioned and removed from service | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
D000202.3 | SGP/OKM/X1 - Station TULL replaced by station PORT | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
D000330.1 | SGP/OKM Overview of Automated QA - October 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000330.3 | SGP/OKM Overview of Automated QA - December 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000330.4 | SGP/OKM Overview of Automated QA - January 2000 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000330.5 | SGP/OKM Overview of Automated QA - February 2000 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000419.1 | SGP/OKM Overview of Automated QA - March 2000 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000524.1 | SGP/OKM Overview of Automated QA - April 2000 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000712.1 | SGP/OKM Overview of Automated QA - May 2000 | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
D000809.1 | SGP/OKM Overview of Automated QA - June 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D000905.1 | SGP/OKM Overview of Automated QA - July 2000 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D010531.1 | SGP/OKM - CATO station retired | sgp05okmX1.a1, sgp15okmX1.a1, sgpokmX1.00 |
D010531.2 | SGP/OKM - BEEX station added | sgp05okmX1.a1, sgp15okmX1.a1, sgpokmX1.00 |
D020228.10 | SGP/OKM/X1 - Overview of Automated Data Quality - September 1999 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D020228.8 | SGP/OKM/X1 - Overview of Automated Data Quality - July 1999 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D020228.9 | SGP/OKM/X1 - Overview of Automated Data Quality - August 1999 | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
D031016.1 | SGP/OKM/X1 - Station Change | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
D990310.1 | SGP/OKM - Overview of Automated QA - January 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
D990409.1 | SGP/OKM - Overview of Automated QA - February 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
D990531.1 | SGP/OKM - Overview of Automated QA - March 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
D990615.1 | SGP/OKM - Overview of Automated QA - April 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
D990722.3 | Overview of Automated QA - May 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
D990812.1 | SGP/OKM Overview of Automated QA - June 1999 | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/17/1998 | 0000 | 06/01/1999 | 0000 |
Subject: | SGP/OKM/X1 - Incorrect Station Identifier and Information |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | On December 17, 1998, the station ALVA was moved from 36.7797, -98.6717, elevation 450 m. to station ALV2 36.7083, -98.7075, elevation 439 m. but the data files contain the old station name and the old station latitude longitude and elevation until we received the June 1999 quality assured files. |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/16/1999 | 0200 | 06/01/1999 | 0000 |
Subject: | SGP/OKM/X1 - Incorrect Station Identifier and Information |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | On March 16, 1999, the station GRAN was moved from 34.2392, -98.7397, elevation 342 m. to station GRA2 34.2392, -98.7444, elevation 341 m. but the data files contain the old station name and the old station latitude, longitude and elevation until we received the June 1999 quality assured files. |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/19/1996 | 0000 | 01/20/2000 | 2359 |
Subject: | SGP/OKM/X1 - Station PRES decommissioned and removed from service |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | The station PRES (Preston) was installed on June 19, 1996 for a grant funded project and removed on January 20, 2000 when the project terminated because it is close to other stations and because it was a frequent victim of vandals. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
sgpokmX1.01:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 11/05/1999 | 2359 |
Subject: | SGP/OKM/X1 - Station TULL replaced by station PORT |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | PORT (Porter) is a station move from TULL (Tullahassee). The landowner was building a house where the Mesonet site stood, so they had to shut down TULL. PORT is another orchard, located about 9 miles west of the TULL site. Station Number: 118 Station ID: PORT Station Name: Porter Nearest Incorporated City: Clarksville 2.5 W County: Wagoner Latitude: 35.8258 degrees N Longitude 95.5600 degrees W Elevation: 193 m Date Commissioned: 1999-11-05 (TULL de-commissioned 1999-11-04) |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
sgpokmX1.01:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/1999 | 0000 | 10/31/1999 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - October 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the October 1999 Oklahoma Mesonet data. There are a few special events in the October data Date Station Parameter(s) ---- ------- ------------ 10/02 TALI TAIR -| Strong low-level inversion caused many 10/13 CHEY TAIR | sites which "poked" into the warmer air 10/20 CHEY TAIR | to be spatially inconsistent with neigh- 10/20 MINC TAIR | boring stations. You can disregard the 10/26 CHEY TAIR -| flags for these stations. ======================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of October, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: Over 375 trouble tickets were issued and reconciled during October-- mainly due to OASIS upgrades. Here's a summary of the tickets that directly affected our data quality. ======================================================================== TAIR Current: None Added: None Resolved: #3386 BEAV Replaced bad thermistor RELH Current: None Added: None Resolved: #3004 BREC Replaced bad sensor #3012 CHER Replaced sensor stuck at 0% #3385 BEAV Replaced bad sensor WDIR Current: None Added: None Resolved: #2711 HOOK Replaced sensor with suspicious direction WSPD Current: #2736 BBOW Sensor suspected of under-reporting during strong winds/severe weather Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #3361 ALTU Monthly QA indicates sensor is reporting ~50 W/m^2 low Added: None Resolved: #3387 BEAV Replaced sensor stuck at -30 #3680 EUFA Replaced sensor with low bias #3838 FTCB Re-leveled pyranometer RAIN Current: #3840 COPA Sensor reported 0.0 during heavy rain Added: None Resolved: #2681 BURB Replaced bad switch #3688 WILB Replaced bad switch TA9M Current: None Added: None Resolved: #3360 BREC Replaced bad thermistor WS2M Current: #3670 MEDI Sensor at improper height Added: None Resolved: #3392 PAUL Sensor moved to proper height TS10 Current: #3001 ADAX Stuck at less than -100.0 C #3003 HOBA Sensor biased 20 C warm #3019 FTCB Sensor reporting numerous observations below -100.0 C Added: None Resolved: #2260 BOWL Replaced sensor damaged by gophers #2673 BURB Replaced lightning-damaged sensor TB10 Current: None Added: None Resolved: #2864 FREE Replaced sensor stuck at -73 C TS05 Current: #2604 HOBA Sensor stuck at -273.1 C Added: None Resolved: #3359 WYNO Suspicious sensor tested ok by tech TB05 Current: #2789 STIG Sensor reporting out of range (over 55 C) Added: None Resolved: #2734 SKIA Replaced suspicious sensor TS30 Current: #2391 HOLL Reported 15 C warm bias for one month, now data seems to be ok #3147 TIPT Sensor stuck at -273.1 C Added: None Resolved: #2674 BURB Replaced lightning damaged sensor #3391 PAUL Re-positioned sensor found to be installed at 15 cm ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #2539 A149 Replaced sensor with low TDEW bias #3025 A152 Replaced faulty sensor #3026 A182 Replaced faulty sensor SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #3835 A134 Replaced sensor with warm bias TS15 Current: None Added: None Resolved: #3024 A163 Replaced sensor with sporadic warm bias TS30 Current: None Added: None Resolved: #3018 A146 Replaced erratic sensor #3685 A167 Replaced sensor damaged by rodents ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/1999 | 0000 | 12/31/1999 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - December 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the December 1999 Oklahoma Mesonet data. There are a few special events in the December Mesonet data Date Station Parameter(s) ---- ------- ------------ 12/06 BUFF TAIR Thin band of snow cover caused this site to be much cooler than neighboring stations. You can ignore the automated QA flags. 12/09 LAHO PRES Meso-low moved very close to this site during heavy thunderstorms. You can disregard the flags. 12/11 BBOW WS2M Absolutely calm conditions all day caused this site to fail our persistence test. You can ignore the flags. 12/16 CALV RELH Localized cold-air drainage occurred at this site. You can disregard the flags. 12/17 SALL TAIR Again, cold-air drainage WIST TAIR Again, cold-air drainage 12/29 CHEY TAIR/TA9M Station poked above inversion layer, ignore the flags MEDI TAIR Station poked above inversion layer, ignore the flags 12/30 WIST TAIR Cold-air drainage. Disregard the flags. OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of December, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: Wintry weather caused the barometer tubes to freeze shut at MARS on 12/5 and at ALV2 and BUFF on 12/10. The problem resolved itslef when temperatures warmed above freezing. The observation times affected were flagged in the Qualparm database. A thin band of snowcover over the northwestern part of the state from 12/5-12/7 played havoc with the spatial automated QA. For instance, on the morning of 12/6, stations within the band of snowcover cooled to as low as 10 F, whereas adjacent sites outside of the band stayed in the upper 20s. ======================================================================= TAIR Current: None Added: None Resolved: #4376 GOOD Replaced sensor damaged by bull RELH Current: None Added: None Resolved: #4375 GOOD Replaced sensor damaged by bull WDIR Current: #4338 MARS Sensor reporting 180 degrees out of phase on numerous occassions Added: None Resolved: #4378 MTHE Replacing nose cone corrected WDIR WSPD Current: #4651 JAYX Sensor reporting 2 m/s lower than WSPD at 9 m Added: None Resolved: #4377 MTHE Replaced bad nose cone PRES Current: #4118 CHEY No barometer hole drilled, sensor is detecting pressure inside enclosure Added: None Resolved: None SRAD Current: None Added: None Resolved: #3361 ALTU Replaced pyranometer that was biased low RAIN Current: #4361 HOLL Gauge tipped 66 times instead of 50 times during drip test Added: None Resolved: #4339 TAHL Replaced bad switch #4370 RING Removed 4 spider webs clogging gauge TA9M Current: None Added: None Resolved: None WS2M Current: #4342 PRES Sensor stuck at 0.0 m/s Added: None Resolved: #3670 MEDI Sensor moved to proper height #4296 PORT Replaced sensor with electrical problem TS10 Current: None Added: None Resolved: #3003 HOBA Replaced bad sensor #4486 WOOD Corrected wiring problem #4490 SLAP Corrected wiring problem TB10 Current: None Added: None Resolved: #4487 WOOD Corrected wiring problem TS05 Current: None Added: None Resolved: #2604 HOBA Replaced sensor stuck at -273.1 C #4488 WOOD Corrected wiring problem TB05 Current: None Added: None Resolved: #4489 WOOD Corrected wiring problem TS30 Current: #3147 TIPT Sensor stuck at -273.1 C Added: None Resolved: #2391 HOLL Replaced bad sensor #4491 SLAP Corrected wiring problem ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: #4647 A145 Replaced sensor failing mesocomp RELH Current: None Added: None Resolved: #4648 A145 Replaced sensor failing mesocomp SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: #4504 A168 Replaced bad switch TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2000 | 0000 | 01/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - January 2000 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the January 2000 Oklahoma Mesonet data. Date Station Parameter(s) ---- ------- ------------ 1/07 BBOW WS2M Completely calm conditions at this site caused the wind speed at 2 m to stay at 0 m/s all day. Although the data was flagged by the persistence test, it is ok. 1/12 BUFF TAIR Cold air drainage caused this site to be much colder than neighboring sites. Ignore the flags. 1/13 BUFF TAIR Cold air drainage caused this site to be much colder than neighboring sites. Ignore the flags. 1/26 BBOW WS2M Completely calm conditions at this site caused the wind speed at 2 m to stay at 0 m/s all day. Although the data was flagged by the persistence test, it is ok. 1/27 CHIC TA9M ---| ELRE RELH | Continuous light snow GUTH RELH | caused the parameters at these MARE RELH | sites to stay constant MARS RELH | all day long. They failed our PERK TA9M | persistence test. You can SPEN RELH | disregard the flags. STIL TA9M | ACME TAIR | ACME TA9M ---| --------------------------------------------------------------- OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of January, 2000 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =============================================================== Notes: The Preston site was removed on 20 January due to repeated vandalism that has occurred there. Other vandalism incidents: 4 January: A149 TAIR and RELH sensor damaged 16 January: CHIC WS2M stolen and datalogger damaged Many improvements were made in January to our soil moisture data. 6 stations had their faulty sensors replaced or repaired during the month. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: #4338 MARS Sensor reporting 180 degrees out of phase on numerous occasions Added: None Resolved: None WSPD Current: None Added: #4832 EUFA Sensor consistently 1-2 m/s slower than WS2M and is local minimum compared to neighbors Resolved: None PRES Current: #4118 CHEY No barometer hole drilled, sensor is detecting pressure inside enclosure #4680 BBOW Observed 32 barometer errors, probably a lose wire #4801 MTHE Observed 75 barometer errors, probably a lose wire Added: None Resolved: None SRAD Current: None Added: #4831 MIAM PM SRAD is consistently 50 W/m^2 higher than neighbors Resolved: None RAIN Current: None Added: #4830 ANTL Site received double the rainfall as neighbors in January. Gauge may be double- tipping again. Resolved: None TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #4769 CHIC Replaced stolen sensor TS10 Current: #4818 STIG Sensor has 15 C warm bias Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: None Added: #4834 FORA Sensor does not agree with other soil levels Resolved: None TB05 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: #3147 TIPT Corrected wiring problem ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: #4670 A149 Replaced vandalized sensor RELH Current: None Added: None Resolved: #4669 A149 Replaced vandalized sensor SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2000 | 0000 | 02/29/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - February 2000 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the February 2000 Oklahoma Mesonet data. ============================================================== OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of February, 2000 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =============================================================== Notes: OASIS 2000 for the northeast quadrant of the state began February 22. OASIS 2000 is an NCAR in-field comparison with our OASIS stations. As part of normal maintenance, the Mesonet Technicians installed updated datalogger operating systems at 24 stations during February. The remainder of the sites will be updated during March. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None WDIR Current: None Added: None Resolved: #4338 MARS Replaced to correct WDIR errors WSPD Current: #4862 NEWK Data indicates low bias #4863 WOOD Data indicates low bias Added: None Resolved: #4832 EUFA Replaced sensor with bad bearings; causing low wspds #4859 SEIL Replaced sensor with bad bearings; causing low wspds #4864 STIG Replaced sensor with bad bearings; causing low wspds #4865 CHEY Replaced sensor with bad bearings; causing low wspds PRES Current: None Added: None Resolved: #4680 BBOW Re-tightened wires to correct barometer errors #4800 BOWL Re-tightened wires to correct barometer errors #4801 MTHE Restripped/Re-tightened wires to correct barometer errors #4833 PUTN Reset logger to correct baro- meter stuck at 0.0 mb #4842 FREE Reset logger to correct baro- meter stuck at 0.0 mb #4866 CHEY Reset logger to correct baro- meter stuck at 0.0 mb SRAD Current: #4831 MIAM PM SRAD is consistently 50 W/m^2 higher than neighbors Added: None Resolved: None RAIN Current: None Added: None Resolved: #4830 ANTL Replaced cable, logger, and wiring panel to correct double- tipping TA9M Current: #4873 WEAT Sensor stuck at -273.1 C Added: None Resolved: None WS2M Current: None Added: None Resolved: #4870 CHIC Replaced dead sensor TS10 Current: None Added: None Resolved: #4818 STIG Replaced sensor with gopher damage TB10 Current: None Added: None Resolved: None TS05 Current: #4834 FORA Sensor does not agree with other soil levels Added: None Resolved: #4875 STIG Replaced sensor that failed in-field comparison TB05 Current: #4872 WYNO Corrected erosion problem Added: None Resolved: None TS30 Current: None Added: None Resolved: #4876 STIG Replaced sensor that failed in-field comparison ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: #4874 A133 Gauge under-reporting rainfall Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2000 | 0000 | 03/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - March 2000 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the March 2000 Oklahoma Mesonet data. There are a few special events in the March Mesonet data that you may want to be aware of. These include: Date Station Parameter(s) ---- ------- ------------ 3/03 CLOU WMAX Gust to 89 mph during severe thunderstorm; you can disregard the automated QA flag 3/02 ARNE PRES Mesolow caused ARNE to be spatially inconsistent with neighboring sites; disregard the automated QA flags =============================================================== OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of March, 2000 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =============================================================== Notes: One last ice storm... Mother Nature coated much of western Oklahoma with freezing rain on March 16-17, causing upwards of 40 wind monitors to freeze solid. These observations were flagged in Qualparm to indicate their suspicious readings. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: None Added: #4927 WASH Monthly QA indicates 1 C high TDEW bias Resolved: None WDIR Current: None Added: None Resolved: #4890 TISH Repaired sensor stuck at 355 degrees WSPD Current: #4863 WOOD Data indicates low bias Added: None Resolved: #4862 NEWK Bearings found noisy and replaced nose cone PRES Current: None Added: #4920 ACME Monthly QA indicates 1 mb high bias #4921 JAYX Monthly QA indicates 1 mb high bias Resolved: None SRAD Current: None Added: #4924 WIST Monthly QA indicates 50 W/m^2 low bias #4925 COPA Monthly QA indicates 75 W/m^2 low bias #4926 MIAM Monthly QA continues to indicates 50 W/m^2 high bias Resolved: #4831 MIAM Replaced sensor to correct high bias RAIN Current: None Added: #4923 JAYX Check for possible clog Resolved: #4901 FTCB Replaced reed switch that was causing gauge to be stuck at 0. TA9M Current: #4902 BYAR Sensor reporting 6 C cool bias Added: None Resolved: #4873 WEAT Replaced bad logger port to correct TA9M problem WS2M Current: None Added: None Resolved: #4879 NORM Corrected bent boom TS10 Current: #4915 WEST Sensor warmer than TS05 in the afternoon Added: None Resolved: None TB10 Current: None Added: None Resolved: None TS05 Current: #4916 WEST Sensor cooler than TS10 in the afternoon Added: None Resolved: #4834 FORA Replaced sensor with cool bias TB05 Current: #4872 WYNO Erosion problem over bare plot Added: #4922 ANTL Possible erosion due to high afternoon bias #4928 MEDF Possible erosion due to high afternoon bias Resolved: None TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: #4874 A133 Fixed loose wire TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2000 | 0000 | 04/30/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - April 2000 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the April 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians are beginning their Spring Pass of all Mesonet and ARS stations. All sites will be visited over the next 2 months to perform routine maintenance, along with point data comparisons of many parameters. In addition, site photos are being taken to document ground cover and a new procedure is being performed to recalibrate our site elevations via test barometers. ================================================================ TAIR Current: None Added: None Resolved: None RELH Current: #4947 ELRE Sensor reporting over 106% during high humidity #4948 MAYR Sensor dropping to 0% Added: None Resolved: #4927 WASH Replaced sensor with 1 C high TDEW bias WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #4863 WOOD Replaced sensor suspected of low bias PRES Current: #4940 FTCB Sensor stuck at 956.0 mb Added: None Resolved: #4920 ACME Barometer tested ok, site elevation recalibrated #4921 JAYX Barometer tested ok, site elevation recalibrated SRAD Current: None Added: None Resolved: #4924 WIST Replaced sensor with low bias #4925 COPA Replaced sensor with low bias #4926 MIAM Replaced sensor with high bias RAIN Current: None Added: None Resolved: #4923 JAYX Removed debris from funnel TA9M Current: None Added: None Resolved: #4902 BYAR Replaced sensor and removed mud-dobber nest from shield WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #4914 SEIL Corrected wiring problem #4915 WEST Corrected wiring problem TB10 Current: None Added: None Resolved: #4913 SEIL Corrected wiring problem #4944 ANTL Corrected erosion problem TS05 Current: #4953 SALL Check for possible wiring problem Added: None Resolved: #4916 WEST Corrected wiring problem TB05 Current: #4928 MEDF Possible erosion due to high afternoon bias Added: None Resolved: #4872 WYNO Corrected erosion problem #4922 ANTL Corrected erosion problem TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: #4903 A110 Replaced rusty switch #4908 A135 Replaced stuck switch TS05 Current: None Added: None Resolved: None TS10 Current: #4949 A151 Sensor jumping erratically from -273 to 70 C Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2000 | 0000 | 05/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - May 2000 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.00, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the May 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians continued site visits during May as part of "Spring Pass 2000". All stations will have received maintenance by the end of June. A cow broke through the enclosure at JAYX on May 12. I've been meaning to tell Ken Meyers I found somebody looking like they were up to no good at the nearby Pryor site: http://radar.metr.ou.edu/cgi-bin/sitephoto.cgi?site=pryo&dir=ne&info=photos Do you think we have our first suspect? (That link comes from our online site photo gallery accessible through the main Mesonet web page at http://okmesonet.ocs.ou.edu.) ================================================================ TAIR Current: #5011 SLAP Sensor reporting -7999 during most observations Added: None Resolved: #4965 JAYX Replaced cow-damaged sensor RELH Current: #4948 MAYR Sensor dropping to 0% #5006 CAMA Sensor reported near 0% RH intermittently #5010 SLAP RELH to 105% #5013 ARDM Sensor reporting over 103% #5014 ALV2 RELH to 108% Added: None Resolved: #4947 ELRE Replaced sensor reporting over 106% #4964 JAYX Replaced cow-damaged sensor WDIR Current: None Added: None Resolved: None WSPD Current: #4976 BYAR Sensor sporadically 4-5 m/s slower than speed at 9 m Added: None Resolved: #4993 CHIC Replaced noisy bearings #5023 ALTU Replaced noisy bearings PRES Current: #4980 RETR Sensor dropped 100 mb on May 18-19 Added: None Resolved: #4940 FTCB Replaced barometer stuck at 956.03 mb SRAD Current: #5009 SLAP Sensor reporting below 0 Added: #5072 KETC Monthly QA indicates 5-10% high bias Resolved: None RAIN Current: None Added: None Resolved: #4962 JAYX Repaired broken wire on cable #4988 TAHL Replaced failed switch #5026 ALTU Replaced intermittently failing switch TA9M Current: #5008 SLAP Sensor reporting below 0 Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5007 SLAP Sensor has 6 C warm bias Added: None Resolved: #4982 SALL Replaced gopher-damaged sensor TB10 Current: None Added: None Resolved: #4968 NORM Reset depth indicator; sensor was 1 cm high #4984 SALL Repaired erosion; sensor was 2 cm high TS05 Current: None Added: None Resolved: None TB05 Current: None Added: None Resolved: #4928 MEDF Corrected erosion problem #4965 NORM Reset depth indicator; sensor was 1 cm high #4985 SALL Repaired erosion; sensor was 2 cm high TS30 Current: #5005 CHIC Sensor stuck at -273.1 Added: None Resolved: #4983 SALL Replaced gopher-damaged sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: #4970 A161 Repaired loose wire RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: #5071 A136 Monthly QA indicates 3-4 C warm bias Resolved: None TS30 Current: None Added: None Resolved: #4966 A131 Replaced sensor with warm bias ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/01/2000 | 0000 | 06/30/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - June 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the June 2000 Oklahoma Mesonet data. =============================================================== Notes: The Mesonet Technicians completed Spring Pass 2000 on June 30. The point comparisons they performed on the TAIR, RELH, PRES, SRAD, and RAIN parameters were very useful for QA of Mesonet data. A number of sensors reporting slightly outside of the Mesonet's acceptable error ranges were identified. Many site photos were taken during Spring Pass 2000 to document vegetation cover around the bare and sod soil temperature plots, the soil heat flux sensors, and the soil moisture plots at each station. Look for those pictures along with the site visitation forms indicating the technician's notes to be available on the web next month. One more note... The monthly analysis for June identified the very heavy rains that fell over east Oklahoma during mid to late June. Westville took top honors with a June total of 17.04 inches! ================================================================ TAIR Current: None Added: None Resolved: #5011 SLAP Replaced malfunctioning sensor RELH Current: #5014 ALV2 RELH to 108% #5074 WIST RELH to 112% #5082 ADAX Sensor found to be 6% high during Spring Pass 2000 comparison #5083 BBOW Sensor found to be 20% high during Spring Pass 2000 comparison #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison #5102 KENT Sensor stuck at 0% for extended period Added: None Resolved: #4948 MAYR Replaced bad sensor #5006 CAMA Replaced bad sensor #5010 SLAP Replaced bad sensor #5013 ARDM Replaced sensor that failed mesocomp #5077 WEST Replaced sensor stuck at 0% #5087 CENT Replaced sensor found to have 5.3% high bias during spring pass 2000 #5094 MARE Replaced sensor found to have 5.9% high bias during spring pass 2000 #5110 BUFF Replaced sensor found to have 6.0% high bias during spring pass 2000 WDIR Current: None Added: None Resolved: None WSPD Current: #4976 BYAR Sensor sporadically 4-5 m/s slower than speed at 9 m Added: None Resolved: #5093 MARE Replaced sensor with noisy bearings #5120 CLAR Replaced sensor with noisy bearings PRES Current: #5086 RETR Sensor found to be .72 mb high during Spring Pass 2000 comparison Added: None Resolved: #4980 RETR Found tube clogged with bug #5046 WIST Replaced bad barometer SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5079 WASH Sensor found to be 23% high during Spring Pass 2000 comparison #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison Added: None Resolved: #5009 SLAP Corrected SRAD problems by replacing bad RH switch RAIN Current: #5078 BURN Gauge recorded no rain during radar-indicated rain event #5098 BESS Gauge found to be double-tipping on one side of bucket during Spring Pass 2000 test Added: None Resolved: #5075 PUTN Replaced bad switch TA9M Current: None Added: None Resolved: #5008 SLAP Corrected TA9M problems by cleaning corroded negative ground WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #5007 SLAP Corrected TS10 problems by cleaning corroded negative ground #5056 SKIA Tightened down power ground port TB10 Current: #5096 BOWL Sensor reports 10 C warm bias during and after rain events Added: None Resolved: #5057 SKIA Tightened down power ground port TS05 Current: None Added: None Resolved: #5058 SKIA Tightened down power ground port TB05 Current: None Added: None Resolved: #5059 SKIA Tightened down power ground port TS30 Current: #5005 CHIC Sensor stuck at -273.1 Added: None Resolved: #5012 SALL Replaced sensor reporting unreasonable values #5060 SKIA Tightened down power ground port ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #5092 A181 Gauge recorded no rain during heavy rain event Added: None Resolved: #5055 A133 Repaired vandalized gauge TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: #5071 A136 Monthly QA indicates 3-4 C warm bias Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2000 | 0000 | 07/31/2000 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - July 2000 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | =============================================================== Notes: The Mesonet Technicians have begun Summer Pass 2000. All sites will be visited between July 15 and September 30. In addition to the routine maintenance that will be performed at each site, many new site photos (including updated panoramic photos) will be taken. Lightning, lightning, lightning... "The July Victims": (1) Fairview (2) Seiling (3) Grandfield (4) Medford base (5) Blackwell base (6) Kiowa Repeater (twice) ================================================================ TAIR Current: None Added: None Resolved: #5100 BEAV Replaced after found to be 0.59 C high during Spring Pass #5102 KENT Sensor found to be dangling from mount #5112 BOIS Replaced after found to be 0.7 C warm during Spring Pass #5113 PUTN Replaced after found to be 0.8 C warm during Spring Pass #5123 CLOU Replaced after found to be 0.6 C warm during Spring Pass #5134 PAWN Replaced bad sensor RELH Current: #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison #5140 MAYR Sensor reported to 108% Added: None Resolved: #5014 ALV2 Replaced after sensor rose to 108% RH #5073 SLAP Replaced after sensor reported erratic dips to 5-10% RH #5074 WIST Replaced after sensor rose to 112% RH #5076 HOOK Replaced after sensor sporadically dipped to 0%. #5082 ADAX Replaced after sensor found to be 6% high during Spring Pass #5083 BBOW Replaced after sensor found to be 20% high during Spring Pass #5085 KENT Repaired sensor found to be dangling from mount #5116 BYAR Replaced after sensor found to be 5.5% high during Spring Pass #5121 IDAB Replaced after sensor found to be 7.2% high during Spring Pass #5122 MTHE Replaced after sensor found to be 8% high during Spring Pass #5124 PERK Replaced after sensor found to be 5.1% high during Spring Pass #5126 SULP Replaced after sensor found to be 7.9% high during Spring Pass WDIR Current: None Added: None Resolved: #5167 SEIL Replaced lightning-damaged sensor WSPD Current: None Added: None Resolved: #4976 BYAR Replaced sensor with loose nut #5117 BYAR Replaced sensor with loose nose cone prop #5130 MINC Replaced nose cone due to bad bearings #5151 CENT Replaced sensor due to noisy bearings #5152 LANE Replaced sensor due to noisy bearings #5153 WIST Replaced sensor due to noisy bearings #5154 WILB Replaced sensor due to noisy bearings #5155 TALI Replaced sensor due to noisy bearings #5156 STUA Replaced sensor due to slightly noisy bearings PRES Current: #5086 RETR Sensor found to be .72 mb high during Spring Pass 2000 comparison Added: None Resolved: #5136 SALL Replaced barometer tube found to be plugged by critter SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5079 WASH Sensor found to be 23% high during Spring Pass 2000 comparison #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: None RAIN Current: #5078 BURN Gauge recorded no rain during radar-indicated rain event #5098 BESS Gauge found to be double-tipping on one side of bucket during Spring Pass 2000 test #5114 CHEY Gauge found to over-report by 6.25% during Spring Pass drip test Added: #5185 TIPT Long term analysis indicates possible under-reporting Resolved: #5142 KING Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset Added: None Resolved: #5096 BOWL Replaced sensor with 10 C warm bias TB10 Current: #5179 SALL TB10 is warmer than TB05 during all times of the day Added: None Resolved: None TS05 Current: None Added: None Resolved: #5127 ANTL Sensor found to be angled upward #5128 BRIS Corrected wiring problem TB05 Current: None Added: None Resolved: #5129 KING 1-2 inches of grass clippings removed from bare plot TS30 Current: None Added: None Resolved: #5005 CHIC Replaced wiring problem ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: #5180 A182 Sensor found to be 2.5 C warm during ARS pass Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5092 A181 Replaced bad switch #5104 A130 Replaced bad switch #5105 A149 Replaced bad switch TS05 Current: None Added: #5181 A132 Monthly QA indicates 4 C warm bias during all times of day Resolved: #5132 A136 Replaced gopher-damaged sensor #5149 A161 Replaced gopher-damaged sensor TS10 Current: None Added: #5182 A167 Monthly QA indicates 4 C warm bias during all times of day Resolved: #5131 A136 Replaced gopher-damaged sensor TS15 Current: None Added: None Resolved: #5071 A136 Replaced gopher-damaged sensor #5139 A137 Replaced reporting frequent data spikes TS30 Current: #5157 A165 Reporting erratic observations Added: None Resolved: #5137 A161 Cable chewed in half and sensor stolen ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 04/19/2001 | 2359 |
Subject: | SGP/OKM - CATO station retired |
DataStreams: | sgp05okmX1.a1, sgp15okmX1.a1, sgpokmX1.00 |
Description: | The Catoosa station (CATO) was decommissioned on April 19 due to poor site exposure and the end of the EPSCOR project. |
Measurements: | sgp05okmX1.a1:
sgp15okmX1.a1:
sgpokmX1.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/OKM - BEEX station added |
DataStreams: | sgp05okmX1.a1, sgp15okmX1.a1, sgpokmX1.00 |
Description: | A new site located at Bee (BEEX) was added beginning on April 1, 2001. It does not appear in data files before that date. |
Measurements: | sgp05okmX1.a1:
sgp15okmX1.a1:
sgpokmX1.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/01/1999 | 0000 | 09/30/1999 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - September 1999 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the September 1999 Oklahoma Mesonet data. ============================================================== There are a few special events in the September data that you may want to be aware of. These include: Date Station Parameter(s) ---- ------- ------------ 09/03 ARNE TAIR Thunderstorm; disregard flags 09/07 BREC TB10, TB05 Rainfall dramatically cooled hot soils; ignore the flags 09/07 NEWK TAIR Thunderstorm; disregard flags 09/07 SALL TAIR Thunderstorm; disregard flags 09/08 BREC TB05 Rainfall dramatically cooled hot soil; ignore the flags 09/08 JAYX PRES Meso-high occured from thunderstorms; ignore the flags 09/08 MARS TB05 Rainfall cooled soil; ignore the flags 09/10 BUFF RELH, TAIR Thunderstorm; disregard flags -Chris ======================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of September, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: The Mesonet technicians were busy in September resolving over 37 trouble tickets. Lightning at OKEM and BRIS, along with the hot summer of 1999 really made the problems pile up. In addition to this, 9 sites were upgraded for the OASIS project, and one site (BOIS) was upgraded to a Super Site. ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #3004 BREC Sensor dropping to near 0% RELH on several occasions #3012 CHER Sensor stuck at 0% RELH Added: None Resolved: #3000 NEWK Replaced sensor stuck at 0% RELH #3016 OKEM Replaced lightning-damaged sensor #3030 BRIS Replaced lightning-damaged sensor WDIR Current: #2711 HOOK Sensor reporting E-NE'ly during southerly flow Added: None Resolved: #3076 OKEM Replaced lightning-damaged sensor WSPD Current: #2736 BBOW Sensor suspected of under-reporting during strong winds/severe weather Added: None Resolved: #3075 OKEM Replaced lightning-damaged sensor #3010 TISH Replaced bad bearings #3011 KING Replaced sensor stuck at 0 m/s #3014 ARDM Replaced noisy bearings PRES Current: None Added: None Resolved: #3150 OILT Repaired sensor stuck at 978.49 mb SRAD Current: None Added: #3361 ALTU Monthly QA indicates sensor is reporting ~50 W/m^2 low Resolved: None RAIN Current: #2681 BURB Switch found to be sticking Added: None Resolved: #2640 ANTL Replaced double-tipping gauge #2797 CHER Replaced faulty switch #2998 WEBB Replaced faulty switch #2999 VINI Replaced faulty switch TA9M Current: None Added: #3360 BREC Roughly half of observations each day are below 0. Resolved: None WS2M Current: None Added: None Resolved: #2946 STIG Replaced sensor stuck at 0.0 m/s #2997 PAUL Replaced noisy bearings #3017 WEBB Removed tall johnson grass that was impeding cup rotation TS10 Current: #2260 BOWL Sensor reporting data spikes and 5 C warm bias #2673 BURB Sensor appears to be biased 5 C warm since lightning strike #3001 ADAX Stuck at less than -100.0 C #3003 HOBA Sensor biased 20 C warm #3019 FTCB Sensor reporting numerous observations below -100.0 C Added: None Resolved: #2831 IDAB Corrected wiring problem #2839 PAWN Corrected wiring problem #2840 TIPT Corrected wiring problem #3077 OKEM Replaced lightning-damaged sensor TB10 Current: #2864 FREE Sensor stuck at -73 C Added: None Resolved: #2799 MIAM Replaced faulty sensor #2833 IDAB Corrected wiring problem #2837 PAWN Corrected wiring problem TS05 Current: #2604 HOBA Sensor stuck at -273.1 C Added: #3359 WYNO Monthly QA indicates 5 C warm bias Resolved: #2832 IDAB Corrected wiring problem #2838 PAWN Corrected wiring problem #2841 TIPT Corrected wiring problem #2993 PRYO Repaired faulty sensor TB05 Current: #2538 CATO Sensor biased 5-10 C warm #2734 SKIA Reporting data spikes in the afternoon and as much as a 10 C warm bias #2789 STIG Sensor reporting out of range (over 55 C) Added: None Resolved: #2719 LAHO Replaced warm-biased sensor #2834 IDAB Corrected wiring problem #2994 PRYO Replaced faulty sensor TS30 Current: #2391 HOLL Reported 15 C warm bias for one month, now data seems to be ok #2674 BURB Sensor biased 12 C cool since lightning strike Added: None Resolved: #2274 SALL Replaced lightning-damaged sensor #2836 PAWN Corrected wiring problem #3078 OKEM Replaced lightning-damaged sensor #3147 TIPT Sensor stuck at -273.1 C ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: #2539 A149 Monthly QA indicates 1.0 C low TDEW bias #3025 A152 Sensor observing many -7999.0 obs #3026 A182 Sensor observing many -7999.0 obs Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: #3024 A163 Sensor biased 8 C warm Added: None Resolved: None TS30 Current: #3018 Sensor failing step test with frequent erratic observations and 5 C warm bias Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/1999 | 0000 | 07/31/1999 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - July 1999 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the July 1999 Oklahoma Mesonet data. ============================================================== There are a few special events that were flagged by the automatic qa in the month of July that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 7/01 MEDF WSPD, WVEC Thunderstorm gusts caused these flags. You can disregard the flagging. 7/01 NEWK PRES Meso-high associated with thunderstorms caused these flags. You can disregard them. -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of July, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: Many trouble tickets were resolved during the month of July by the Mesonet Technicians. The lightning-damaged sites of CLAY, BURB, OKEM, and A182 were all brought back to full-performance. In addition, the T/RH sensors were replaced at ELRE, MAYR, PAWN, RING, KING, GRA2, BREC, A135, A151, and A167 to eliminate suspicious or problematic sensors from the field. One final note- Ken Meyers discovered vandalism to the rain gauge at A134 and replaced it. ======================================================================== TAIR Current: None Added: None Resolved: #2561 CLAY Sensor installed after original damaged by lightning #2679 BURB Sensor replaced due to lightning damage #2788 ELRE Sensor replaced after 0.5 C cool bias found during meso-comp #2617 MAYR Replaced sensor stuck at -7999.0 RELH Current: #2669 WALT Open RH switch #2394 BRIS Data sporadically drops to less than 10% RH Added: None Resolved: #2151 RING Replaced sensor reporting erratic data dips #2295 PAWN Replaced sensor possibly damaged by storm #2376 KING Replaced sensor with suspected 2 C warm TDEW bias #2562 CLAY Replaced lightning-damaged sensor #2678 BURB Replaced lightning-damaged sensor #2683 GRA2 Replaced sensor reporting erratic data dips #2377 MAYR Replaced faulty sensor #2639 BREC Replaced sensor stuck at -7999 WDIR Current: #2718 DURA Sensor stuck at 0 degrees for extended periods #2711 HOOK Sensor reporting E-NE'ly during southerly flow Added: None Resolved: #2276 BBOW Replaced sensor sticking during low winds #2533 ACME Replaced sensor damaged by vandalism #2672 CHER Replaced datalogger to correct incorrect WDIR observations WSPD Current: #2632 WEST Sensor sticking frequently at 0 m/s #2670 DURA Sensor stuck at 0 m/s #2736 BBOW Sensor suspected of under-reporting during strong winds/severe weather Added: None Resolved: #2437 ACME Replaced sensor damaged by vandalism PRES Current: None Added: None Resolved: #2620 SULP Replaced tube clogged with bugs and mud #2720 STIL Replaced barometer reporting spikes and dips #2722 CALV Removed bug from barometer tube SRAD Current: #2669 WALT Sensor reporting -1 at night due to open RH switch Added: None Resolved: #2534 OKEM Replaced lightning-damaged sensor #2560 CLAY Replaced lightning-damaged sensor #2688 BURB Replaced lightning-damaged sensor #2618 MAYR Corrected SRAD observations below 0 by replacing T/RH sensor RAIN Current: #2640 ANTL Gauge appears to be double-tipping #2681 BURB Switch found to be sticking Added: None Resolved: #2655 OILT Replaced gauge suspect of under-reporting TA9M Current: #2792 MIAM Awaiting installation when sensor becomes available Added: None Resolved: None WS2M Current: #2536 STIG Sensor stuck at 0 m/s #2671 DURA Sensor sticking at 0 m/s for extended periods Added: None Resolved: None TS10 Current: #2260 BOWL Sensor reporting data spikes and 5 C warm bias #2656 WALT Sensor biased 10 C cool #2673 BURB Sensor appears to be biased 5 C warm since lightning strike Added: None Resolved: #2637 CHER Replaced datalogger to correct bad TS10 observations #2633 COPA Replaced sensor with 10 C warm bias TB10 Current: #2735 STUA Sensor spiked, then rose steadily to over 53 C Added: None Resolved: #2636 CHER Replaced datalogger to correct bad TB10 observations TS05 Current: #2604 HOBA Sensor stuck at -273.1 C Added: None Resolved: None TB05 Current: #2538 CATO Sensor biased 5-10 C warm #2719 LAHO Sensor reports erratically every afternoon #2734 SKIA Reporting data spikes in the afternoon and as much as a 10 C warm bias #2789 STIG Sensor reporting out of range (over 55 C) Added: None Resolved: #2619 ACME Replaced sensor with warm bias TS30 Current: #2274 SALL Sensor damaged by lightning #2391 HOLL Reporting 15 C warm bias #2730 BURB Sensor biased 12 C cool since lightning strike Added: None Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: #2539 A149 Monthly QA indicates 1.0 C low TDEW bias Added: None Resolved: #2715 A135 Replaced sensor with 7% high RH bias #2710 A131 Repaired broken control line #2716 A167 Replaced sensor with 7% high RH bias #2717 A151 Replaced sensor with 5% high RH bias SRAD Current: None Added: None Resolved: #2714 A182 Replaced lightning-damaged sensor RAIN Current: None Added: None Resolved: #2721 A153 Replaced bad switch #2801 A134 Replaced gauge damaged by vandals TS05 Current: None Added: None Resolved: #2606 A154 Replaced failed sensor #2682 A144 Suspicious spensor checked and no problems found TS10 Current: None Added: None Resolved: #2634 A164 Replaced sensor found to be 8 C warm TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: #2603 A121 Replaced sensor reporting erratic jumps ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/01/1999 | 0000 | 08/31/1999 | 2359 |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - August 1999 |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the August 1999 Oklahoma Mesonet data. ============================================================== There are a few special events that were flagged by the automatic qa in August that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 8/02 TALI TAIR Localized storm caused this station to be MUCH cooler than neighbors. The data failed the spatial test, but you can disregard the flags. 8/04 MEDI TAIR Same 8/10 BOWL TAIR Same 8/12 PAWN TAIR Same 8/13 CLOU TAIR Same 8/23 CLAR TAIR Same 8/26 MTHE TAIR Same 8/27 ARNE TAIR Same -Chris Fiebrich Mesonet QA Manager ======================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of August, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: The ARS site of A137 was vandalized on August 23. The solar panel and battery were damaged there. VINI was struck by lightning on August 11. Fortunately, damage was contained to only the T/RH sensor. In addition to replacing the damaged sensor, some of the other hardware were replaced at VINI to be on the safe side. And finally, 12 Mesonet sites received OASIS upgrades during the month. ======================================================================== TAIR Current: None Added: None Resolved: #2808 HINT Replaced faulty sensor #2920 VINI Replaced lightning-damaged sensor RELH Current: None Added: None Resolved: #2394 BRIS Replaced sensor with erratic observations #2669 WALT Replaced sensor with open RH switch #2807 HINT Replaced faulty sensor #2919 VINI Replaced lightning-damaged sensor WDIR Current: #2711 HOOK Sensor reporting E-NE'ly during southerly flow Added: None Resolved: #2718 DURA Replaced logger can WSPD Current: #2736 BBOW Sensor suspected of under-reporting during strong winds/severe weather Added: None Resolved: #2632 WEST Replaced sensor stuck at 0.0 m/s #2670 DURA Replaced logger can to correct WSPD problem PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #2640 ANTL Gauge appears to be double-tipping #2681 BURB Switch found to be sticking #2797 CHER Gauge stuck at 0 mm during heavy rainfall Added: None Resolved: #2798 PAWN Repaired wiring problem causing under- reporting of rainfall #2809 ADAX Removed spider web that was clogging tipping bucket TA9M Current: None Added: None Resolved: #2792 MIAM Installed sensor when it became available WS2M Current: #2946 STIG Sensor again stuck at 0.0 m/s Added: None Resolved: #2536 STIG Wired sensor during OASIS upgrade #2671 DURA Replaced logger can to correct under- reporting of WS2M TS10 Current: #2260 BOWL Sensor reporting data spikes and 5 C warm bias #2673 BURB Sensor appears to be biased 5 C warm since lightning strike #2831 IDAB Wiring problem #2839 PAWN Wiring problem #2840 TIPT Wiring problem Added: None Resolved: #2656 WALT Replaced lightning-damaged sensor TB10 Current: #2799 MIAM Sensor reporting continuous -7999. #2833 IDAB Wiring problem #2837 PAWN Wiring problem #2864 FREE Sensor stuck at -73 C Added: None Resolved: #2735 STUA Found gopher damage and replaced sensor #2794 BURN Fixed wiring problem TS05 Current: #2604 HOBA Sensor stuck at -273.1 C #2832 IDAB Wiring problem #2838 PAWN Wiring problem #2841 TIPT Wiring problem #2993 PRYO Sensor reporting below -100.0 C frequently Added: None Resolved: None TB05 Current: #2538 CATO Sensor biased 5-10 C warm #2719 LAHO Sensor reports erratically every afternoon #2734 SKIA Reporting data spikes in the afternoon and as much as a 10 C warm bias #2789 STIG Sensor reporting out of range (over 55 C) #2834 IDAB Wiring problem #2994 PRYO Sensor reporting below -100.0 C frequently Added: None Resolved: #2793 BURN Fixed wiring problem TS30 Current: #2274 SALL Sensor damaged by lightning #2391 HOLL Reported 15 C warm bias for one month, now data seems to be ok #2674 BURB Sensor biased 12 C cool since lightning strike #2836 PAWN Wiring problem Added: None Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: #2539 A149 Monthly QA indicates 1.0 C low TDEW bias Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #2790 A159 Corrected wiring problem TS30 Current: None Added: None Resolved: #2791 A159 Corrected wiring problem ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1994 | 0000 | 09/28/2003 | 2359 |
Subject: | SGP/OKM/X1 - Station Change |
DataStreams: | sgp05okmX1.a1, sgp05okmX1.b1, sgp15okmX1.a1, sgp15okmX1.b1, sgpokmX1.01 |
Description: | The Mesonet station near Marshall was moved on September 25, 2003 to improve accessiblity for the Mesonet technicians who visit and maintain the site. The new site has the code MRSH. It replaces the old Marshall site that had the code MARS. Since the latitude and longitude of the stations are included in the cdf file, users of these data should not have a problem. |
Measurements: | sgp15okmX1.b1:
sgp05okmX1.b1:
sgp05okmX1.a1:
sgp15okmX1.a1:
sgpokmX1.01:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/1999 | 0000 | 01/31/1999 | 2359 |
Subject: | SGP/OKM - Overview of Automated QA - January 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the January 1999 Oklahoma Mesonet data. There are a few special events that were flagged by the automatic QA that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 01/06 CHEY TAIR - Station poked above the cold inversion layer; disregard the flags. 01/12 SALL TAIR - Cold-air drainage at this low-lying site caused it to be spatially inconsis- tent with neighboring stations; ignore the flags. 01/18 MEDI TAIR - Station poked above the cold inversion layer; disregard the flags. 01/19 WIST RELH,TAIR - Cold-air drainage at this low-lying site caused it to be spatially inconsis- tent with neighboring stations; ignore the flags. 01/24 CHEY TAIR - Station poked above the cold inversion layer; disregard the flags. 01/28 BBOW WS2M - Completely calm conditions held the wind speed at 2-m at 0.0 m/s all day long; this caused our persistence program to flag the data. Disregard the flags. 01/30 CHAN,MIAM PRES - Wind gusts to 45+ mph caused pressure spikes; ignore the flags. -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of January, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) =========================================================================== Notes: After a fairly long dry spell, the last weekend of January brought 1 to 2 inch rainfall totals to most sites in the Mesonet. This event brought to our attention an under-reporting gauge at NOWA. Along with the rainfall, the Panhandle stations got quite a bit of freezing rain and snow. The 10-m wind sensors were most affected this time around. GOOD, BEAV, HOOK, and SLAP all had their anemometers freeze solid as the ice accumulated. And now, on to the report... =========================================================================== TAIR Current: #2189 SLAP Long-term QA indicates possible 1.5 C warm bias Added: None Resolved: #2181 ALV2 Sensor reporting frequent -7999 replaced RELH Current: #2151 RING Sensor sporadically reporting ~30% too low Added: None Resolved: #2144 MANG Sensor reporting low Max RH replaced #2173 SEIL Replaced erratically reporting sensor #2190 PRYO Replaced sensor with 1 C warm TDEW bias #2206 PRES Sensor replaced after vandalism WDIR Current: None Added: None Resolved: #2205 PRES Sensor replaced after vandalism WSPD Current: None Added: None Resolved: #2178 BREC Sensor with lose bearings replaced #2180 ALV2 Repaired lose wire and corrosion which was causing frequent 0.0 m/s reports #2204 PRES Sensor replaced after vandalism #2209 CHAN Replaced sensor shot with rifle PRES Current: #2186 SLAP Long-term QA indicates possible low bias Added: None Resolved: None SRAD Current: None Added: #2212 SPEN Sensor consistently reports lower than neighboring sites Resolved: None RAIN Current: #2211 NOWA Gauge reported 0.00" during heavy rainfall event Added: None Resolved: None TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #2203 PRES Sensor replaced after vandalism TS10 Current: #2161 FAIR Sensor reporting constant -219.3 C Added: #2188 HINT Monthly QA indicates 2-3 C cool bias Resolved: None TB10 Current: None Added: #2213 GUTH Monthly QA indicates 2-3 C warm bias Resolved: #2183 WYNO Replaced sensor with sporadic low bias #2200 BREC Added soil removed by erosion #2208 PRES Sensor replaced after vandalism TS05 Current: #2160 FAIR Sensor reporting constant -57.3 C #2187 HINT Long-term QA indicates 2 C cool bias Added: None Resolved: None TB05 Current: #2015 ELRE Sensor reporting 2 C warmer than neighboring sites Added: None Resolved: #2185 BRIS Replaced sensor with 5.5 C warm bias #2199 BREC Added soil removed by erosion #2205 PRES Sensor replaced after vandalism TS30 Current: #2157 TIPT Sensor reporting constant -56.0 C #2184 FTCB Long-term QA indicates 1-2 C cool bias Added: None Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: #2179 A155 Sensor reports as high as 105 0uring conditions of hight relative humidity Added: None Resolved: #2196 A124 Replaced sensor with 1.8 C high TDEW bias #2202 A164 Replaced sensor with 1.5 C high TDEW bias SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: #2194 A164 Replaced sensor with 4 C warm bias TS10 Current: None Added: #2214 A110 Monthly QA indicates 4 C warm bias Resolved: None TS15 Current: None Added: None Resolved: #2201 A164 Replaced sensor with slight warm bias and biting in insulation TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/1999 | 0000 | 02/28/1999 | 2359 |
Subject: | SGP/OKM - Overview of Automated QA - February 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the February 1999 Oklahoma Mesonet data. There are a few special events that were flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 02/05 WIST RELH - Cold-air drainage at this low-lying site caused it to be spatially inconsis- tent with neighboring stations; ignore the flags. 02/08 CHEY TAIR - Station poked above the cold inversion layer; disregard the flags. 02/13 CHEY RELH, TAIR - Station poked above the cold inversion layer; disregard the flags. 02/23 MEDI TAIR - Station poked above the cold inversion layer; disregard the flags. 02/25 BUFF TAIR - Station poked above the cold inversion layer; disregard the flags. 02/28 CHEY,MEDI TAIR - Stations poked above the cold inversion layer; disregard the flags. -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of February, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================== Notes: The Mesonet's Top 3 Most Wanted (Gophers, that is): 1. 'Chubby', 8" Charges: Cut TS10 and TS05 cables Last seen in Fairview, OK 2. 'Shorty', 7" Charges: Chewed TS30 cable in half Last seen in Tipton, OK 3. 'Gnaws', 12" Charges: Damaged TS05, TS10, and TS15 sensors Last seen near Chickasha, OK (A110) On to the report... ======================================================================== TAIR Current: None Added: None Resolved: #2189 SLAP Replaced sensor with 1.5 C warm bias RELH Current: #2151 RING Sensor sporadically reporting ~30% too low #2228 STIG Sensor reporting data dips to near 0% RELH frequently Added: None Resolved: None WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #2186 SLAP Replaced sensor with 1.0 mb low bias SRAD Current: #2212 SPEN Sensor consistently reports lower than neighboring sites Added: None Resolved: None RAIN Current: None Added: None Resolved: #2211 NOWA Replaced bad switch which was causing under-reporting TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #2188 HINT Long-term QA indicates 2-3 C cool bias Added: #2234 MINC Monthly QA indicates 3 C warm bias Resolved: #2161 FAIR Sensor cable cut by gopher TB10 Current: #2213 GUTH Long-term QA indicates 2-3 C warm bias Added: None Resolved: #2219 VINI Sensor found to be 6 C high; replaced TS05 Current: #2187 HINT Long-term QA indicates 2 C cool bias Added: None Resolved: #2160 FAIR Sensor cable cut by gopher; replaced TB05 Current: #2015 ELRE Sensor reporting 2 C warmer than neighboring sites Added: None Resolved: None TS30 Current: #2184 FTCB Long-term QA indicates 1-2 C cool bias Added: None Resolved: #2157 TIPT Sensor cable chewed in half by gopher ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: #2179 A155 Sensor reports as high as 105 0uring conditions of high relative humidity Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: #2222 A110 Found gopher damage; replaced sensor TS10 Current: None Added: None Resolved: #2214 A110 Gopher damage causing 6 C warm bias; replaced sensor TS15 Current: None Added: None Resolved: #2223 A110 Found gopher damage; replaced sensor TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/1999 | 0000 | 03/31/1999 | 2359 |
Subject: | SGP/OKM - Overview of Automated QA - March 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the March 1999 Oklahoma Mesonet data. There are a few special events that were flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 03/01 MEDI TAIR - Station poked above the cold inversion layer; disregard the flags. 03/15-16 MEDF TAIR - Isolated deep snow cover caused this station's temperatures to be much colder than neighbors; ignore flags -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of March, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================== Notes: Vandalization: The A149 Micronet station suffered extensive damage shortly after midnight on March 17. All sensors were damaged except TS05, TS10, and TS30. ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #2151 RING Sensor sporadically reporting ~30% too low Added: None Resolved: #2228 STIG Replaced sensor reporting near 0% RH WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #2242 BESS Replaced sensor with broken shaft PRES Current: None Added: None Resolved: #2240 STIG Lose wire found to be cause of stuck pressure readings SRAD Current: #2212 SPEN Sensor consistently reports lower than neighboring sites Added: None Resolved: #2239 MEDI Replaced sensor stuck at 0 W/m RAIN Current: None Added: None Resolved: #2238 ALV2 Reed switch broken; causing momentary contacting of switch elements TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #2188 HINT Long-term QA indicates 1-2 C cool bias #2234 MINC Monthly QA indicates 3 C warm bias #2236 VINI Warm bias, data spikes, and multiple observations of -273.1 C noted Added: #2260 BOWL Sensor reporting data spikes and 10 C warm bias Resolved: None TB10 Current: #2213 GUTH Long-term QA indicates 2-3 C warm bias Added: None Resolved: None TS05 Current: #2187 HINT Long-term QA indicates 1-2 C cool bias Added: None Resolved: None TB05 Current: #2015 ELRE Sensor reporting 2 C warmer than neighboring sites Added: None Resolved: None TS30 Current: #2184 FTCB Long-term QA indicates 1-2 C cool bias Added: None Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #2179 A155 Replaced sensor which reported as high as 105 0uring high humidity #2248 A149 Replaced sensor damaged by vandalism SRAD Current: None Added: None Resolved: #2249 A149 Replaced sensor damaged by vandalism RAIN Current: None Added: None Resolved: #2251 A149 Replaced funnel broken by vandalism TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #2250 A149 Insulation cut when site vandalized TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/1999 | 0000 | 04/30/1999 | 2359 |
Subject: | SGP/OKM - Overview of Automated QA - April 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the April 1999 Oklahoma Mesonet data. There is one special event that was flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 04/04 BYAR,MEDI TAIR,RELH - Stations poked above the cold inversion layer; disregard the flags. -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of April, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================== Forces of Nature: SHAW, SALL and CLAY were each struck by lightning during the month of April, causing varying degrees of damage to the instrumentation at those sites. CLAY is no stranger to lightning strikes. This was its third strike since its birth in March of 1994. As a preview to next month's QA report, I'd like to note that CLAY saw its FOURTH strike just last week! Bulls were reported to have attacked BRIS during April, knocking down a pyranometer stand, destroying the temperature and RH sensor, and causing damage to the rain gauge there. Mischievous cows also knocked down the pyranometer stand at WASH. On to the report... ======================================================================== TAIR Current: None Added: None Resolved: #2263 BRIS Sensor destroyed by bull #2275 SALL Sensor destroyed by lightning #2383 CLAY Sensor damaged by lightning RELH Current: #2151 RING Sensor sporadically reporting data spikes #2295 PAWN Sensor damaged by storm #2297 CHIC Sensor sticking at 0% RELH Added: #2327 COPA Sensor reached a max RH of only 94.7% during the month of April #2377 MAYR Monthly QA indicates 1.5 C low TDEW bias #2376 KING Monthly QA indicates 2 C high TDEW bias Resolved: #2262 BRIS Sensor destroyed by bull #2270 SALL Sensor destroyed by lightning #2382 CLAY Sensor damaged by lightning WDIR Current: #2276 BBOW Sensor possibly sticking during low winds Added: None Resolved: #2277 SHAW Lightning strike damaged wind tranzorbs #2384 CLAY Possible lightning damage; lab tested WSPD Current: None Added: None Resolved: #2385 CLAY Possible lightning damage; lab tested PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #2212 SPEN Sensor found to have greater than 5% error #2264 BRIS Stand knocked over by bull #2266 WASH Stand knocked down by cows #2268 SALL Sensor destroyed by lightning strike #2386 CLAY Sensor damaged by lightning RAIN Current: None Added: None Resolved: #2267 BRIS Gauge repaired after bull attack TA9M Current: #2326 CLAY Sensor stuck at -459 C Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #2188 HINT Long-term QA indicates 1-2 C cool bias #2234 MINC Monthly QA indicates 5 C warm bias #2260 BOWL Sensor reporting data spikes and 5 C warm bias Added: None Resolved: #2236 VINI Replaced sensor reporting data spikes #2387 CLAY Sensor damaged by lightning TB10 Current: #2213 GUTH Long-term QA indicates 10 C warm bias #2325 MARE Sensor reporting 5 C warm bias Added: #2329 IDAB Monthly QA indicates 5 C warm bias Resolved: #2324 WYNO Replaced sensor with intermittent data spikes TS05 Current: #2187 HINT Long-term QA indicates 1-2 C cool bias Added: None Resolved: #2388 CLAY Sensor damaged by lightning TB05 Current: None Added: #2328 HOBA Monthly QA indicates 4 C cool bias at night, 4 C warm bias during day Resolved: #2015 ELRE Replaced sensor with warm bias #2259 NORM Repaired sensor with lose wire #2389 CLAY Sensor damaged by lightning TS30 Current: #2184 FTCB Long-term QA indicates 1-2 C warm bias #2274 SALL Sensor damaged by lightning Added: None Resolved: #2390 CLAY Sensor damaged by lightning ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #2296 A148 Gauge stopped reporting during heavy rain event Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== Chris Fiebrich May 10, 1999 |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/1999 | 0000 | 05/30/1999 | 2359 |
Subject: | Overview of Automated QA - May 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the May 1999 Oklahoma Mesonet data. There are a few special events that were flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 5/9 ERIC WSPD Localized thunderstorms produced strong winds at ERIC; disregard the flags 5/10 HOLL PRES Intense thunderstorm and meso- high moved near the HOLL site; disregard the flags 5/17 CHEY WSPD, WS2M Thunderstorm caused localized wind gusts of 70 mph at this site; you can ignore the flags ERIC PRES | Strong thunderstorms and meso-highs PUTN PRES |------- moved over these sites causing their TIPT PRES | pressure observations to be spatially off; disregard the flags 5/20 CAMA PRES Localized intense thunderstorm and high wind gusts caused this site's pressure observations to be spatially inconsistent with neighbors; ignore the flags 5/23 HASK WSPD Strong wind speeds to over 65 mph associated with thunderstorms caused this data to be flagged; disregard the flags 5/26 TIPT WSPD Meso-low forming in advance of a strong thunderstorm caused the strong winds at TIPT; ignore the flags -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of May, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #2151 RING Sensor sporadically reporting data spikes #2295 PAWN Sensor damaged by storm #2376 KING 2 C warm TDEW bias suspected #2377 MAYR 1.5 C low TDEW bias suspected #2394 BRIS Data sporadically drops to less than 10% RH #2486 ALV2 Sensor reporting constant 0% RH Added: None Resolved: #2297 CHIC Replaced sensor stuck at 0% RH WDIR Current: #2276 BBOW Sensor possibly sticking during low winds #2393 CHER Sensor reporting easterly winds during periods of strong westerlies Added: None Resolved: None WSPD Current: None Added: None Resolved: #2407 NORM Tightened wires at site to remedy false wind observations of 0 m/s #2408 NOWA Replaced nose cone to fix sticking PRES Current: #2441 GUTH Sensor reported 40 mb drop in 12 h #2442 WEAT Sensor reported 80 mb drop in 12 h #2487 OILT Sensor reporting long-duration data dips of as much as 80 mb daily Added: None Resolved: None SRAD Current: #2440 WALT Sensor reporting numerous data spikes daily #2501 CHIC Sensor reporting recurrent data dips to 0 W/m during daytime hours Added: None Resolved: None RAIN Current: #2405 ANTL Gauge suspected to be double-tipping Added: None Resolved: None TA9M Current: #2326 CLAY Sensor stuck at -459 C Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #2188 HINT Long-term QA indicates 1-2 C cool bias #2234 MINC Monthly QA indicates 5-10 C warm bias #2260 BOWL Sensor reporting data spikes and 5 C warm bias Added: None Resolved: #2434 SEIL Repaired wiring problem TB10 Current: #2213 GUTH Long-term QA indicates 10 C warm bias Added: None Resolved: #2433 SEIL Repaired wiring problem #2329 IDAB Replaced sensor with warm bias #2325 MARE Sensor tested fine during site visit TS05 Current: #2187 HINT Long-term QA indicates 1-2 C cool bias Added: None Resolved: #2432 SEIL Repaired wiring problem TB05 Current: None Added: None Resolved: #2435 SEIL Repaired wiring problem #2328 HOBA Rock in soil causing erroneous sensor depth; removed rock and re-installed sensor TS30 Current: #2184 FTCB Long-term QA indicates 1-2 C warm bias #2274 SALL Sensor damaged by lightning #2391 HOLL Reporting 15 C warm bias Added: None Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: #2539 A149 Monthly QA indicates 1.0 C low TDEW bias Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #2296 A148 Replaced bad switch TS05 Current: #2438 A155 Sensor biased 10 C warm Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== Chris Fiebrich June 10, 1999 |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/01/1999 | 0000 | 06/30/1999 | 2359 |
Subject: | SGP/OKM Overview of Automated QA - June 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.a1, sgp15okmX1.00, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the June 1999 Oklahoma Mesonet data. There are a few special events that were flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 6/1 FTCB,HOBA PRES Intense thunderstorm and meso-high moved near the FTCB and HOBA sites; disregard the flags HOLL PRES Intense meso-low moved near the HOLL site; disregard the flags MAYR WSPD Thunderstorm winds to 85 mph at MAYR caused it to spatially in- consistent with neighboring sites; you can ignore the flags MAYR PRES Meso-low; disregard the flags RETR PRES Meso-high; disregard the flags 6/2 SALL PRES Meso-high; disregard the flags 6/3-6/30 MAYR SRAD Faulty relative humidity sensor caused the solar radiation readings to dip slightly below zero over night (ie, to -1 or -2 Watts/m^2). The data is fine, however, and you can ignore the flags 6/24 SULP PRES Intense meso-high; disregard the flags 6/25 HOLL WSPD Wind gusts to 63 mph caused this site to be spatially inconsistent with neigh- bors; you can disregard the flags 6/29 MTHE PRES Meso-high; disregard the flags SALL WSPD Wind gusts to 77 mph; disregard the QA flags 6/30 MINC,WASH PRES Meso-low; ignore the flags -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of June, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: Lightning struck at WALT, OKEM, and A182 during June. All 3 sites suf- fered damage to their dataloggers, radios, and wiring panels. In addition, the pyranometer and RH sensor at OKEM were damaged, while the soil moisture sensors, rain gauge, and numerous soil temperature sensors were damaged at WALT. A182 also required a new pyranometer due to its strike. After thorough Mesocomp performed by Ken Meyers in the ARS network, numerous T/RH sensors were replaced in late June and early July in anticipation of SGP99. ======================================================================== TAIR Current: #2561 CLAY Awaiting installation after lightning damage #2617 MAYR Sensor stuck at -7999.0 Added: None Resolved: None RELH Current: #2151 RING Sensor sporadically reporting data spikes #2295 PAWN Sensor damaged by storm; data appears ok since 6/1/99 #2376 KING 2 C warm TDEW bias suspected #2377 MAYR 1.5 C low TDEW bias suspected #2394 BRIS Data sporadically drops to less than 10% RH #2562 CLAY Awaiting installation since lightning damage #2639 BREC Sensor sticking at -7999 for extended periods Added: None Resolved: #2486 ALV2 Replaced malfunctioning sensor #2557 OKEM Replaced lightning-damaged sensor WDIR Current: None Added: None Resolved: #2276 BBOW Replaced sensor sticking during low winds #2533 ACME Replaced sensor damaged by vandalism WSPD Current: #2632 WEST Sensor sticking frequently at 0 m/s #2670 DURA Sensor stuck at 0 m/s Added: None Resolved: #2437 ACME Replaced sensor damaged by vandalism PRES Current: #2620 SULP Sensor spiked, then dropped 40 mb on 6/17 Added: None Resolved: #2441 GUTH Removed dirt clump from barometer tube #2487 OILT Removed insect pupal cases from baro tube #2638 NORM Fixed broken power wire SRAD Current: #2534 OKEM Sensor damaged by lightning #2560 CLAY Sensor damaged by lightning #2618 MAYR Sensor reporting -2 at night due to open RH switch #2669 WALT Sensor reporting -1 at night due to open RH switch Added: None Resolved: #2440 WALT Removed bird droppings covering pyranometer #2501 CHIC Replaced suspicious pyranometer #2625 FTCB Replaced sensor stuck at 0 W/m^2 RAIN Current: #2640 ANTL Gauge appears to be double-tipping #2655 OILT Gauge stuck at 0 during multiple rain events Added: None Resolved: #2626 WALT Replaced bad switch #2635 WIST Tech found grass overgrown 2 feet above gauge; cut grass #2641 KETC Re-leveled gauge found unlevel TA9M Current: None Added: None Resolved: None WS2M Current: #2536 STIG Sensor stuck at 0 m/s #2671 DURA Sensor sticking at 0 m/s for extended periods Added: None Resolved: None TS10 Current: #2260 BOWL Sensor reporting data spikes and 5 C warm bias #2633 COPA Observed data spike and 10 C warm bias #2637 CHER Sensor stuck at -273.1 C #2656 WALT Sensor biased 10 C cool Added: None Resolved: #2188 HINT Replaced sensor suspected of having slight cool bias #2234 MINC Replaced sensor with 3 C warm bias TB10 Current: #2636 CHER Sensor stuck at -273.1 C Added: None Resolved: #2213 GUTH Sensor found with holes and cuts near probe end causing warm bias #2605 WALT Replaced lightning-damaged sensor #2621 MANG Weeds found covering bare plot TS05 Current: #2604 HOBA Sensor stuck at -273.1 C Added: None Resolved: #2187 HINT Replaced sensor suspected of cool bias TB05 Current: #2538 CATO Sensor biased 5-10 C warm #2619 ACME Sensor biased 5 C warm Added: None Resolved: #2622 MANG Weeds found covering bare plot TS30 Current: #2274 SALL Sensor damaged by lightning #2391 HOLL Reporting 15 C warm bias Added: None Resolved: #2184 FTCB Replaced sensor suspected of warm bias ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: #2539 A149 Monthly QA indicates 1.0 C low TDEW bias Added: None Resolved: #2649 A160 Sensor found to be 6 0gh; replaced #2650 A159 Sensor found to be 6 0gh; replaced SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #2392 A159 Replaced bad switch #2443 A135 Leaf found covering funnel hole TS05 Current: #2606 A154 Sensor stuck at -273.1 C Added: None Resolved: #2438 A155 Sensor found to be 18 C warm; replaced TS10 Current: #2634 A164 Sensor biased 6 C warm Added: None Resolved: None TS15 Current: None Added: None Resolved: #2537 A159 Replaced suspect sensor TS30 Current: #2603 A121 Sensor observed erratic jumps between 26 C and 35 C Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== Chris Fiebrich July 9, 1999 |
Measurements: | sgp15okmX1.00:
sgp05okmX1.00:
sgp05okmX1.a1:
sgp15okmX1.a1:
|