DQR ID | Subject | Data Streams Affected |
---|---|---|
D040904.2 | TWP/SKYRAD/C3 - Incorrect NIP cal coefficient | twpskyrad60sC3.b1 |
D050104.1 | TWP/SKYRAD/C3 - Reprocess: NIP calibrations incorrect | twpskyrad60sC3.b1, twpskyradC3.00 |
D051114.3 | TWP/SKYRAD/C3 - tracker inoperative | twpskyrad20sC3.a0, twpskyrad60sC3.b1, twpskyradC3.00 |
D060110.3 | TWP/SKYRAD/C3 - IRT damaged | twpskyrad20sC3.a0, twpskyrad60sC3.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/24/2004 | 0000 | 09/02/2004 | 2350 |
Subject: | TWP/SKYRAD/C3 - Incorrect NIP cal coefficient |
DataStreams: | twpskyrad60sC3.b1 |
Description: | During our site visit comparison at Darwin we observed that the skyrad NIP was reading about 50 w/m2 lower than the comparison cavity radfiometer and the replacement NIP on the comparison stand. We found that the calibration coefficient for the NIP (responsivity at 45o)was put in as 8.64X10-6. The NIP was new and had not been calibrated at SGP. The factory number was 8.04X10-6. We corrected the calibration coefficient and the instruments agreed to better than 5 w/m2. |
Measurements: | twpskyrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2004 | 0000 | 09/02/2004 | 0400 |
Subject: | TWP/SKYRAD/C3 - Reprocess: NIP calibrations incorrect |
DataStreams: | twpskyrad60sC3.b1, twpskyradC3.00 |
Description: | On 05/20 during installtion of the new Campbell datalogger system and associated program the NIP (S/N 33551E6) was assigned an incorrect calibration coefficient. A coefficient of 116.01 W/m2/mV was applied when it should have been 124.378 W/m2/mV. TWP reports SV0405D and SV0409D detail the activities which lead to this DQR. |
Measurements: | twpskyradC3.00:
twpskyrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2005 | 0453 | 12/02/2005 | 0000 |
Subject: | TWP/SKYRAD/C3 - tracker inoperative |
DataStreams: | twpskyrad20sC3.a0, twpskyrad60sC3.b1, twpskyradC3.00 |
Description: | A lightning strike at Darwin removed the tracker from service. Instruments installed on the tracker were rendered either inoperative or were not shaded during this time period. The longwave hemispheric instruments PIR1 and PIR2 appear to have been unaffected. They are not suseptable to incorrect tracker operation. The downwelling hemispheric shortwave PSP instrument mounted on Skyrad will not be affected by incorrect tracker operation. |
Measurements: | twpskyradC3.00:
twpskyrad60sC3.b1:
twpskyrad20sC3.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2005 | 2314 | 03/07/2006 | 0257 |
Subject: | TWP/SKYRAD/C3 - IRT damaged |
DataStreams: | twpskyrad20sC3.a0, twpskyrad60sC3.b1 |
Description: | The analog output of the IRT was damaged by a lightning strike. The problem was corrected by replacing the instrument with a spare. The damaged IRT was returned to the vendor for repair. |
Measurements: | twpskyrad60sC3.b1:
twpskyrad20sC3.a0:
|