DQR ID | Subject | Data Streams Affected |
---|---|---|
D070308.3 | TWP/SONDE/C2 - Surface Temperature Incorrect | twpsondewnpnC2.b1 |
D070428.1 | TWP/SONDE/C2 - Broken temperature sensor at launch | twpsondewnpnC2.b1 |
D070501.2 | TWP/SONDE/C2 - Broken temperature sensor at launch | twpsondewnpnC2.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/02/2007 | 1128 | 01/02/2007 | 1129 |
Subject: | TWP/SONDE/C2 - Surface Temperature Incorrect |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The first two temperature values in the datafile are incorrect. It appears that the observer mis-typed the surface temperature as -27 instead of +27. The next value was 8 which is also incorrect and was caused by the system interpolating from the incorrect surface value and what the sonde temperature sensor was reading. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/27/2007 | 1140 | 04/27/2007 | 1420 |
Subject: | TWP/SONDE/C2 - Broken temperature sensor at launch |
DataStreams: | twpsondewnpnC2.b1 |
Description: | Temperature sensor broken at launch. All thermodynamic values are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/30/2007 | 2359 | 05/01/2007 | 0200 |
Subject: | TWP/SONDE/C2 - Broken temperature sensor at launch |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|