Data Quality Reports for Session: 129317 User: dmfoper Completed: 07/31/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050117.11SGP/EBBR/E2 - BA EBBR VAP Bulk Aerodynamicssgp30baebbrE2.c1


DQRID : D050117.11
Start DateStart TimeEnd DateEnd Time
05/22/1997210006/30/20032359
Subject:
SGP/EBBR/E2 - BA EBBR VAP Bulk Aerodynamics
DataStreams:sgp30baebbrE2.c1
Description:
Fixed AEM and wind speed sensor heights were improperly used in the
calculation of bulk aerodynamic sensible and latent heat fluxes instead of
site specific heights.
      
This resulted in either under-estimation or over-estimation of the sensible
and latent heat fluxes.
Measurements:sgp30baebbrE2.c1:
  • Friction velocity(austar)
  • Aerodynamic Sensible heat flux(ah)
  • Best estimate Sensible heat flux(hcomb)
  • Best estimate Latent heat flux(ecomb)
  • Aerodynamic Latent heat flux(ale)


Back To Table of Contents



END OF DATA