DQR ID | Subject | Data Streams Affected |
---|---|---|
D040722.2 | NSA/METTWR/C1 - Chilled Mirror transmit logic board chipset unsuited for Arctic temperatures | nsamettwr4hC1.b1 |
D041214.1 | NSA/METTWR/C1 - All 10m level Data Missing | nsamettwr4hC1.b1 |
D050527.2 | NSA/METTWR/C1 - Incorrect Maximum for Precip Values | nsamettwr4hC1.b1 |
D051025.2 | NSA/METTWR/C1 - Data 1-minute behind | nsamettwr4hC1.b1 |
D051101.4 | NSA/METTWR/C1 - Reprocess: Wind direction data incorrect | nsamettwr4hC1.b1 |
D060817.4 | NSA/METTWR/C1 - Reprocess: Barometric Data Changed from hPa to kPa | nsamettwr4hC1.b1 |
D061213.1 | NSA/METTWR/C1 - CMH Sensor Calibrated Incorrectly | nsamettwr4hC1.b1 |
D061213.2 | NSA/METTWR/C1 - 40m wind sensor heater failure | nsamettwr4hC1.b1 |
D070529.1 | NSA/METTWR/C1 - 20m RH Data Questionable | nsamettwr4hC1.b1 |
D080326.2 | NSA/METTWR/C1 - 2m Wind Direction Sensor Freezing | nsamettwr4hC1.b1 |
D080408.2 | NSA/METTWR/C1 - CMH Intake Fan Failure | nsamettwr4hC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2003 | 0000 | 04/23/2004 | 1858 |
Subject: | NSA/METTWR/C1 - Chilled Mirror transmit logic board chipset unsuited for Arctic |
DataStreams: | nsamettwr4hC1.b1 |
Description: | Data missing due to problems with manufacturer's transmit logic board chipset. They were generic chips not rated for Arctic temperatures. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/13/2004 | 2002 | 04/26/2005 | 1902 |
Subject: | NSA/METTWR/C1 - All 10m level Data Missing |
DataStreams: | nsamettwr4hC1.b1 |
Description: | After prolonged power outage and many power spikes during the outage all data from the 10m level are missing. Blown fuse on the power supply was replaced once the temperatures warmed enough to allow the lowering of the tower carriages. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/31/2003 | 0000 | 05/26/2005 | 1014 |
Subject: | NSA/METTWR/C1 - Incorrect Maximum for Precip Values |
DataStreams: | nsamettwr4hC1.b1 |
Description: | The max values for cumulative rain sum of 99 mm and the rain rate of 999 mm/hr are incorrect. In communication with the manufacturer it has been found that the manual was in error. The actual max values of the cumulative rain sum is 99.99 mm and the rain rate is 999.99 mm/hr. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/31/2003 | 0000 | 09/14/2005 | 1420 |
Subject: | NSA/METTWR/C1 - Data 1-minute behind |
DataStreams: | nsamettwr4hC1.b1 |
Description: | Data from the Barometer, Chilled Mirror Hygrometer and the Present Weather Sensor were one-minute behind due to timing problems collecting data from the Serial Data Multiplexer that handled these sensors. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/31/2003 | 0000 | 10/20/2005 | 1900 |
Subject: | NSA/METTWR/C1 - Reprocess: Wind direction data incorrect |
DataStreams: | nsamettwr4hC1.b1 |
Description: | Wind direction data is off by 30 degrees for all wind sensors. The 40-m tower was misaligned to true north. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/31/2003 | 0000 | 07/12/2006 | 1608 |
Subject: | NSA/METTWR/C1 - Reprocess: Barometric Data Changed from hPa to kPa |
DataStreams: | nsamettwr4hC1.b1 |
Description: | Barometric pressure data was converted from hPa to kPa in order to standardize the measurement units among ARM sites and to conform to accepted standard units determined by the scientific community. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2006 | 1500 | 03/14/2007 | 0234 |
Subject: | NSA/METTWR/C1 - CMH Sensor Calibrated Incorrectly |
DataStreams: | nsamettwr4hC1.b1 |
Description: | The CMH temp and DP were higher than the co-located T/RH probe at the 2m level. An incorrect calibration along with a failing thermistor caused the readings to be incorrect for both measured values Temp and Dew Point. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2006 | 0000 | 05/22/2007 | 2347 |
Subject: | NSA/METTWR/C1 - 40m wind sensor heater failure |
DataStreams: | nsamettwr4hC1.b1 |
Description: | The 40m wind direction became frozen at times. The values from the sensor were flat-lined (stdev = 0) much of the time and did not match sensors from other levels. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/18/2006 | 0000 | 05/22/2007 | 2330 |
Subject: | NSA/METTWR/C1 - 20m RH Data Questionable |
DataStreams: | nsamettwr4hC1.b1 |
Description: | The 20m RH data was questionable at times. When the data appeared to be poor was when the 2m and 20m agreed better than the 20m and the 40m and/or 10m. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2008 | 0000 | 03/27/2008 | 1730 |
Subject: | NSA/METTWR/C1 - 2m Wind Direction Sensor Freezing |
DataStreams: | nsamettwr4hC1.b1 |
Description: | The 2m wind direction was failing. It began to exhibit instances of no movement suggesting it was frozen. After some time it began to make erratic measurements compared to the co-located Ultrasonic and compared to the directions at the other levels. |
Measurements: | nsamettwr4hC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/07/2008 | 1200 | 03/13/2008 | 2345 |
Subject: | NSA/METTWR/C1 - CMH Intake Fan Failure |
DataStreams: | nsamettwr4hC1.b1 |
Description: | The CMH intake fan failed causing the dew point and temp data to be incorrect. If users need only T/RH and derived variables they can use the 2m data collected using the HMP-45D probes. CMH data are unrecoverable. |
Measurements: | nsamettwr4hC1.b1:
|