DQR ID | Subject | Data Streams Affected |
---|---|---|
D090902.9 | SGP/ECOR/E3 - Pressure and Temperature Missing | sgp30ecorE3.b1 |
D110204.1 | SGP/SEBS/E14 - Instrument logger problem | sgp30ecorE14.b1 |
D110322.2 | SGP/SEBS/E14 - Soil Moisture Measurements Incorrect | sgp30ecorE14.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/19/2009 | 1600 | 10/24/2009 | 2100 |
Subject: | SGP/ECOR/E3 - Pressure and Temperature Missing |
DataStreams: | sgp30ecorE3.b1 |
Description: | Pressure and temperature from the LI-7500 are missing. This did not affect the sensible and latent heat fluxes, however, much of the ECOR data is missing during this period. Attempts to correct the problem were unsuccessful until the time of site decommissioning. This facility was decommissioned and maintenance efforts ceased 10/1/2009. |
Measurements: | sgp30ecorE3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/19/2010 | 2100 | 01/31/2011 | 1900 |
Subject: | SGP/SEBS/E14 - Instrument logger problem |
DataStreams: | sgp30ecorE14.b1 |
Description: | SEBS soil moisture measurements had been recorded as minimum soil moisture since the start of the SEBS installation at E14. Soil heat capacity calculations were also incorrect as a result of the problem. Instrument was mis-identified as ECOR in the DQPR. Since the SEBS datastream was not available to list, I have had to select an ECOR datastream just to be able to submit this DQR. Please add the SEBS to my listing of instrument systems for the purpose of submitting DQRs. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/19/2010 | 2100 | 01/31/2011 | 1900 |
Subject: | SGP/SEBS/E14 - Soil Moisture Measurements Incorrect |
DataStreams: | sgp30ecorE14.b1 |
Description: | Soil Moisture measurements were incorrect because of a loose lead. |
Measurements: | sgp30ecorE14.b1:
|