DQR ID | Subject | Data Streams Affected |
---|---|---|
D110131.1 | SBS/MET/M1 - Atmospheric pressure spikes | sbsmetM1.b1 |
D110131.2 | SBS/MET/M1 - Site setup | sbsmetM1.b1 |
D110221.4 | SBS/MWR/M1 - Missing data | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
D110221.5 | SBS/MWR/M1 - Instrument not well calibrated | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
D110221.6 | SBS/MWR/M1 - Reprocessed: Incorrect retrievals | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
D110228.2 | SBS/AOSB/S2 - Instrument malfunction | sbsaosozoneS2.00, sbsaosozoneS2.a1 |
D110228.3 | SBS/AOSB/S2 - Missing data | sbsaosozoneS2.a1 |
D110317.2 | SBS/MWR/M1 - Temperature instability | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
D110414.3 | SBS/MWR/M1 - Instrument problem | sbsmwrM1.00, sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
D110513.2 | SBS/MET/M1 - Incorrect atmospheric pressure | sbsmetM1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/15/2010 | 0000 | 01/28/2011 | 2000 |
Subject: | SBS/MET/M1 - Atmospheric pressure spikes |
DataStreams: | sbsmetM1.b1 |
Description: | A nearby AC unit was causing +/-.05 (approx.) changes in pressure values, most frequently during the daylight hours but occasionally over night. Corrective action was taken to shield the sensor 1/28. |
Measurements: | sbsmetM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/27/2010 | 0000 | 11/15/2010 | 0000 |
Subject: | SBS/MET/M1 - Site setup |
DataStreams: | sbsmetM1.b1 |
Description: | The instruments were being setup and installed during this period. Some data may be questionable and minimal quality reporting will be done. |
Measurements: | sbsmetM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/15/2010 | 0000 | 01/12/2011 | 0000 |
03/11/2011 | 2000 | 03/14/2011 | 1400 |
03/17/2011 | 1500 | 03/23/2011 | 2000 |
03/27/2011 | 1300 | 04/01/2011 | 1300 |
Subject: | SBS/MWR/M1 - Missing data |
DataStreams: | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
Description: | Data are missing and unrecoverable. |
Measurements: | sbsmwrlosM1.b1:
sbsmwrtipM1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2011 | 0000 | 01/14/2011 | 0000 |
Subject: | SBS/MWR/M1 - Instrument not well calibrated |
DataStreams: | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
Description: | After being installed the instrument needed some time to stabilize and collect some tip data. |
Measurements: | sbsmwrlosM1.b1:
sbsmwrtipM1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/25/2010 | 0000 | 04/25/2011 | 2359 |
Subject: | SBS/MWR/M1 - Reprocessed: Incorrect retrievals |
DataStreams: | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
Description: | The PWV and LWP retrievals at this site were incorrect for lack of radiosonde data. At the end of the deployment, the mentor provided new retrieval coefficients and the MWRLOS data were reprocessed and archived. The MWRTIP data have not yet been reprocessed. The correction of these data are in the reprocessing queue at a low priority. |
Measurements: | sbsmwrlosM1.b1:
sbsmwrtipM1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/22/2010 | 1756 | 12/27/2010 | 2055 |
Subject: | SBS/AOSB/S2 - Instrument malfunction |
DataStreams: | sbsaosozoneS2.00, sbsaosozoneS2.a1 |
Description: | By mistake a filter spacer was installed instead of filter. This shut off flow to the instrument. All data during this period is invalid. |
Measurements: | sbsaosozoneS2.a1:
sbsaosozoneS2.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/18/2011 | 2013 | 02/20/2011 | 2139 |
02/21/2011 | 0247 | 02/21/2011 | 2204 |
Subject: | SBS/AOSB/S2 - Missing data |
DataStreams: | sbsaosozoneS2.a1 |
Description: | Data are missing and unrecoverable. |
Measurements: | sbsaosozoneS2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2011 | 0000 | 02/03/2011 | 0000 |
Subject: | SBS/MWR/M1 - Temperature instability |
DataStreams: | sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
Description: | The radiometer was thermally unstable due to the extremely cold outside temperature. Data are suspect. |
Measurements: | sbsmwrlosM1.b1:
sbsmwrtipM1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/14/2011 | 1400 | 03/17/2011 | 1500 |
03/23/2011 | 2000 | 03/27/2011 | 1300 |
Subject: | SBS/MWR/M1 - Instrument problem |
DataStreams: | sbsmwrM1.00, sbsmwrlosM1.b1, sbsmwrtipM1.a1 |
Description: | The fan in the dewblower malfunctioned from 3/11 to 3/30. During this time it is likely that snow deposited on the radome during snowfall events and it stayed on the radome longer than usual. |
Measurements: | sbsmwrM1.00:
sbsmwrlosM1.b1:
sbsmwrtipM1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/07/2011 | 1945 | 04/12/2011 | 1400 |
Subject: | SBS/MET/M1 - Incorrect atmospheric pressure |
DataStreams: | sbsmetM1.b1 |
Description: | The atmospheric pressure readings showed a ~.3 - 1 mb oscillatory behavior. The sensor tube was found to be obstructed. It was fixed and proper function resumed. |
Measurements: | sbsmetM1.b1:
|