Subject: | SGP/EBBR/E9 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
|
Description: | The right Air Temperature probe leads were loose.
During nighttime the right Air Temperature went offscale,
resulting in incorrect sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE9.b1: - temp_air_bottom
- bowen_ratio
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
- Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
- temp_air_top
sgp15ebbrE9.b1:
sgp5ebbrE9.b1: - temp_air_top
- temp_air_bottom
|