DQR ID | Subject | Data Streams Affected |
---|---|---|
D020329.8 | TWP/SMET/C1/C2 - Switch to new Data Header Formats not timely | twpsmet60sC1.a1, twpsmet60sC1.b1, twpsmet60sC2.a1, twpsmet60sC2.b1 |
D030317.1 | TWP/SMET/C1 - Reprocess: Lower Wind Speed incorrect | twpsmet60sC1.a1, twpsmet60sC1.b1 |
D050421.6 | TWP/SMET/C1 - Negative rainfall rates | twpsmet60sC1.b1 |
D060817.3 | TWP/SMET/C1 - Reprocess: Barometric pressure units change | twpsmet60sC1.b1 |
D061011.2 | TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge added | twpsmet60sC1.b1 |
D081022.3 | TWP/SMET/C1 - Wind Speed data contain offset due to induced voltage | twpsmet60sC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/31/2001 | 2359 | 04/01/2001 | 0020 |
Subject: | TWP/SMET/C1/C2 - Switch to new Data Header Formats not timely |
DataStreams: | twpsmet60sC1.a1, twpsmet60sC1.b1, twpsmet60sC2.a1, twpsmet60sC2.b1 |
Description: | On April 1, 2001 at 00:00:00 new data header with consistent variable naming conventions, etc were to be used for all sites, all data streams. At the TWP sites the time of the movement to the new convention did not occur precisely at 00:00:00. The following data files contain between 40 seconds and 20 minutes of data from 4/1/02 in the old format. The delayed format change did not affect data quality in any way. twpsmet60sC1.a1.20010401.000001.cdf twpsmet60sC1.b1.20010401.000001.cdf twpsmet60sC2.a1.20010401.000000.cdf twpsmet60sC2.b1.20010401.000000.cdf |
Measurements: | twpsmet60sC2.b1:
twpsmet60sC1.b1:
twpsmet60sC1.a1:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/27/2003 | 1750 | 03/03/2003 | 1900 |
Subject: | TWP/SMET/C1 - Reprocess: Lower Wind Speed incorrect |
DataStreams: | twpsmet60sC1.a1, twpsmet60sC1.b1 |
Description: | The lower wind speed sensor (sensor #2) was reporting values 10 times above the actual value. During an update to the logger configuration file the calibration multiplier was incorrectly entered. The multiplier inserted was .97630 when it should have been .09763. This caused the readings from this sensor to be incorrect. |
Measurements: | twpsmet60sC1.b1:
twpsmet60sC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/1996 | 0000 | 03/09/2004 | 2243 |
Subject: | TWP/SMET/C1 - Negative rainfall rates |
DataStreams: | twpsmet60sC1.b1 |
Description: | Due to limitations of the Zeno dataloggers all voltage measurements from the optical rain gauge (ORG) were converted to rainfall rates. This resulted in negative values for rain rates. Any value below 0.10 mm/hr should be considered to be 0 mm/hr. New dataloggers alleviated this problem. New loggers were installed 03/09/2004 @ 2243 GMT. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/1996 | 0000 | 08/02/2004 | 1911 |
Subject: | TWP/SMET/C1 - Reprocess: Barometric pressure units change |
DataStreams: | twpsmet60sC1.b1 |
Description: | Barometric pressure data during this time period is reported in hPa. After this time, the data have been converted to kPa to standardize the measurement units among ARM sites and to conform to accepted standard units determined by the scientific community. |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/1996 | 0000 | 10/17/2006 | 0000 |
Subject: | TWP/SMET/C1 - Reprocess: Tipping bucket rain gauge added |
DataStreams: | twpsmet60sC1.b1 |
Description: | A tipping bucket rain gauge was added to the TWP.C1 SMET suite of instruments on 20061017. Effective 20060926, two new variables (count and rain amount) were added to the end of the twpsmet60sC1.b1 datastream. Between 9/26 and 10/17, the data for these two variables are filled with zeros. Users should not use the data during this period as the zeros are not representative of the rain fall at the site. When reprocessing of this datastream occurs these variables will be added for the 19961009-20060926 and data from 19961009-20061017 will be filled with -9999 (missing). |
Measurements: | twpsmet60sC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/1996 | 0000 | 11/03/2008 | 0730 |
Subject: | TWP/SMET/C1 - Wind Speed data contain offset due to induced voltage |
DataStreams: | twpsmet60sC1.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | twpsmet60sC1.b1:
|