DQR ID | Subject | Data Streams Affected |
---|---|---|
D000221.4 | SGP/EBBR - EBBR E19 Wind Speed Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D000228.1 | SGP/EBBR - EBBR E20 Right Air Temperature Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D000303.1 | SGP/EBBR - EBBR E20 Left Air Temperature Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D010213.13 | SGP/EBBR/E2 - EBBR E2 Wind Speed Iced | sgp15ebbrE2.b1, sgp5ebbrE2.b1, sgp30ebbrE2.b1 |
D010213.6 | SGP/EBBR/E19 - EBBR E19 Wind Speed Iced | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
D010213.7 | SGP/EBBR/E20 - EBBR E20 Wind Speed Iced | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D010213.8 | SGP/EBBR/E22 - EBBR E22 Wind Speed Iced | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
D010302.1 | SGP/EBBR/E2 - E2 EBBR Most Data Incorrect | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D010302.19 | SGP/EBBR/E2 - E2 EBBR Data Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D010302.2 | SGP/EBBR/E2 - E2 EBBR Ts4 and SM4 Bouncing Around | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D010302.20 | SGP/EBBR/E2 - E2 EBBR Ts2 Incorrect | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D010302.21 | SGP/EBBR/E2 - E2 EBBR Wind Direction Incorrect | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D010302.22 | SGP/EBBR/E2 - E2 EBBR Data Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D010302.23 | SGP/EBBR/E2 - E2 EBBR Low Battery Condition | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D010302.24 | SGP/EBBR/E2 - E2 EBBR Left Aspirator Fan Stopped | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
D010302.25 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D010302.26 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D010302.27 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D010302.28 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D010302.29 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
D010302.30 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
D010302.31 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D010302.32 | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D010427.11 | SGP EBBR E22 - E22 EBBR Data Incorrect During Logger Replacement | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.00 |
D010427.13 | SGP EBBR E22 - E22 EBBR Soil Moisture Lower Than Measurement Capability | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D010427.14 | SGP EBBR E22 - E22 EBBR Soil Moisture #3 Lower Than Can Be Measured | sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
D010427.15 | SGP EBBR E22 - E22 EBBR Net Radiation Incorrect | sgp30ebbrE22.b1, sgp15ebbrE22.b1, sgp5ebbrE22.b1 |
D010427.5 | SGP EBBR E19 - E19 EBBR Left Aspirator Housing Off | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D010427.6 | SGP EBBR E19 - E19 EBBR Left Air Temperature Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D010427.7 | SGP EBBR E19 - E19 EBBR Data Incorrect During J-panel Replacement | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D010427.8 | SGP EBBR E19 - E19 EBBR Wind Direction Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D010427.9 | SGP EBBR E19 - E19 EBBR Soil Heat Flow #1 Sign Reversed | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D010517.1 | SGP EBBR E20 - E20 EBBR Soil Heat Flow #3 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D010517.2 | SGP EBBR E20 - E20 EBBR Right Air T Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D010517.3 | SGP EBBR E20 - E20 EBBR Right Air T Incorrect | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D010605.11 | SGP EBBR E20 - E20 EBBR Soil Temperatures Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D010605.12 | SGP EBBR E20 - E20 EBBR Data Incorrect During STP #3 Replacement | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00 |
D010605.13 | SGP EBBR E20 - E20 EBBR Data Incorrect After Program Restart | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00 |
D010605.14 | SGP EBBR E20 - E20 EBBR Some Data Incorrect | sgp30ebbrE20.b1 |
D010605.7 | SGP EBBR E20 - E20 EBBR Data Incorrect | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00 |
D010605.8 | SGP EBBR E20 - E20 EBBR Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D010605.9 | SGP EBBR E20 - E20 EBBR Net Radiation Data Incorrect | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D011102.3 | SGP EBBR E19 - E19 EBBR Soil Temperature 3 Intermittenmtly Incorrect | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D011102.7 | SGP EBBR E19 - E19 EBBR TS3 Intermittent Incorrect | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D011102.8 | SGP EBBR E19 - E19 EBBR Wind Speed Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D011127.21 | SGP EBBR E2 - E2 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D011127.30 | SGP EBBR E19 - E19 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D011127.31 | SGP EBBR E20 - E20 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D011127.32 | SGP EBBR E22 - E22 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D011127.4 | SGP EBBR E20 - E20 EBBR Soil Temperature #3 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D011206.4 | SGP EBBR E22 - E22 EBBR 30 Minute Data Incorrect After Missing Data | sgp30ebbrE22.b1 |
D011218.10 | SGP EBBR E20 - E20 EBBR Soil Heat Flow #2 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D011218.11 | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Incorrect Data | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D011218.13 | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D011218.14 | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D011218.9 | SGP EBBR E20 - E20 EBBR Soil Heat Flow #4 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D020115.1 | SGP/EEBR/E2 - AEM Stopped In One Position | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D020115.2 | SGP/EEBR/E2 - AEM Stopped In One Position | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D020115.3 | SGP/EEBR/E2 - Wind Direction Frozen | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
D020115.4 | SGP/EEBR/E2 - Wind Speed Sensor Frozen | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
D020115.5 | SGP/EEBR/E2 - Soil Temperature #2 Incorrect | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D020117.14 | SGP/EBBR/E2 - Reprocess: E2 EBBR Soil Temperature #2 Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D020117.23 | SGP/EBBR/E2 - Reprocess: E2 EBBR Soil Temperature #2 Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D020117.4 | SGP/EBBR/E2 - Reprocess: E2 EBBR Soil Temperature #2 Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D020716.15 | SGP/EBBR/E19 - 6 Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D020716.16 | SGP/EBBR/E20 - 6 Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020716.17 | SGP/EBBR/E22 - 6 Month Checks | sgp30ebbrE22.b1, sgp5ebbrE22.b1, sgp15ebbrE22.b1 |
D020716.19 | SGP/EBBR/E2 - AEM Hung | sgp30ebbrE2.b1, sgp15ebbrE2.b1, sgp5ebbrE2.b1 |
D020716.20 | SGP/EBBR/E2 - Wind Direction Incorrect | sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D020716.21 | SGP/EBBR/E2 - Reprocess: Soil Temperature #2 Incorrect | sgp30ebbrE2.b1 |
D020716.22 | SGP/EBBR/E2 - Data Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp5ebbrE2.00 |
D020716.5 | SGP/EBBR/E2 - 6 Month Checks | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
D020716.6 | SGP/EBBR/E2 - 6 Month Checks | sgp30ebbrE2.b1, sgp15ebbrE2.b1, sgp5ebbrE2.b1 |
D020717.26 | SGP/EBBR/E19 - Reprocess: Soil Heat Flow #3 Incorrect | sgp30ebbrE19.b1 |
D020717.27 | SGP/EBBR/E19 - Reprocess: Soil Temperature #3 Incorrect | sgp30ebbrE19.b1 |
D020717.29 | SGP/EBBR/E19 - Most Measurements Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D020717.30 | SGP/EBBR/E19 - All Measurements Zero | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D020717.31 | SGP/EBBR/E19 - Pressure Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D020717.32 | SGP/EBBR/E19 - Measurements Incorrect After CR10 Replacement | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D020717.33 | SGP/EBBR/E19 - Low Battery Voltage | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
D020717.34 | SGP/EBBR/E22 - All Measurements Zero | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1, sgp5ebbrE22.00 |
D020717.35 | SGP/EBBR/E22 - AEM Hung or High Home Signals | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D020717.40 | SGP/EBBR/E20 - AEM Hung | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020717.42 | SGP/EBBR/E20 - Battery Voltage Low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D020717.43 | SGP/EBBR/E20 - Pressure Almost Constant | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020717.45 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #3 Incorrect During Sensor Changeout | sgp30ebbrE20.b1 |
D020717.46 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 Has a Negative Offset | sgp30ebbrE20.b1 |
D020717.47 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #4 Incorrect | sgp30ebbrE20.b1 |
D020717.48 | SGP/EBBR/E20 - Measurements Zero | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D020717.49 | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect | sgp30ebbrE20.b1 |
D020717.50 | SGP/EBBR/E20 - Measurements Incorrect During Sensor Changeout | sgp30ebbrE20.b1 |
D020717.51 | SGP/EBBR/E20 - Measurements Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D020726.1 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 and #4 incorrect | sgp30ebbrE20.b1 |
D021113.1 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE9.b1, sgp30ebbrE8.b1, sgp30ebbrE22.b1, sgp30ebbrE20.b1, sgp30ebbrE4.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE2.b1, sgp30ebbrE26.b1, sgp30ebbrE7.b1 |
D021113.4 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
D030110.24 | SGP/EBBR/E19 - Data Incorrect during 6 month checks | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D030110.25 | SGP/EBBR/E20 - Data Incorrect during 6 month checks | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D030110.26 | SGP/EBBR/E22 - Data Incorrect during 6 month checks | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D030110.28 | SGP/EBBR/E2 - Data Incorrect during 6 month checks | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D030113.13 | SGP/EBBR/E2 - REPROCESS: Soil Heat Flow #2 Incorrect | sgp30ebbrE2.b1 |
D030116.10 | SGP/EBBR/E19 - REPROCESS: Soil Heat Flow #3 Incorrect Calibration | sgp30ebbrE19.b1 |
D030116.11 | SGP/EBBR/E19 - Water in Net Radiometer Dome | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030116.6 | SGP/EBBR/E19 - Incorrect data after power interruption | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030116.7 | SGP/EBBR/E19 - Most Measurements Zero following Restart | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030116.8 | SGP/EBBR/E19 - REPROCESS: Soil Temperature #3 Incorrect | sgp30ebbrE19.b1 |
D030116.9 | SGP/EBBR/E19 - REPROCESS: Soil Heat Flow #1 Incorrect | sgp30ebbrE19.b1 |
D030117.1 | SGP/EBBR/E19 - Pressure Low | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030117.10 | SGP/EBBR/E20 - Data Zero following logger restarts | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.11 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #2 Incorrect | sgp30ebbrE20.b1 |
D030117.12 | SGP/EBBR/E20 - Change of Energy Storage Incorrect | sgp30ebbrE20.b1 |
D030117.13 | SGP/EBBR/E20 - Battery voltage low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.14 | SGP/EBBR/E20 - Wind speed and direction frozen | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE2.b1 |
D030117.16 | SGP/EBBR/E22 - AEM Hung between home positions | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D030117.17 | SGP/EBBR/E22 - Water inside Broken Net Rad Dome | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D030117.18 | SGP/EBBR/E20 - AEM Hung between Home Positions | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.19 | SGP/EBBR/E20 - REPROCESS: Heat Flow #3 and #5 Incorrect | sgp30ebbrE20.b1 |
D030117.2 | SGP/EBBR/E20 - Data incorrect during instrument maintenance | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.20 | SGP/EBBR/E20 - REPROCESS: Soil Heat Flow #5 Incorrect | sgp30ebbrE20.b1 |
D030117.22 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 Incorrect | sgp30ebbrE20.b1 |
D030117.25 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #3 Incorrect | sgp30ebbrE20.b1 |
D030117.3 | SGP/EBBR/E20 - Resistance-based Measurements Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.4 | SGP/EBBR/E19 - Soil Temperatures #2 and #3 Intermittently Bad | sgp30ebbrE19.b1 |
D030117.6 | SGP/EBBR/E19 - Measurements zero following logger restart | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030117.7 | SGP/EBBR/E19 - Change of Energy Storage Incorrect | sgp30ebbrE19.b1 |
D030117.8 | SGP/EBBR/E20 - REPROCESS: Net Rad Coefficients Incorrect | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030121.1 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 and Soil Heat Flow #5 Incorrect | sgp30ebbrE20.b1 |
D030711.10 | SGP/EBBR/E20 - RHtop Zero | sgp30ebbrE20.b1 |
D030711.11 | SGP/EBBR/E19 - Soil Temperature #2 Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D030711.12 | SGP/EBBR/E19 - All Data Zeros | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030711.13 | SGP/EBBR/E19 - Several Soil Measurements Incorrect | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D030711.14 | SGP/EBBR/E19 -Several Soil Measurements Were Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D030711.16 | SGP/EBBR/E19 - AEM Hung in home30 position | sgp30ebbrE19.b1 |
D030711.17 | SGP/EBBR/E19 - Soil Heat Flow #3 Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D030711.19 | SGP/EBBR/E19 - Soil Heat Flow#1 Incorrect | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D030711.20 | SGP/EBBR/E19 - Many Measurements Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D030711.7 | SGP/EBBR/E22 - home30 too large | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D030711.8 | SGP/EBBR/E20 - Soil Heat Flow#5 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D030711.9 | SGP/EBBR/E20 - Soil Storage Incorrect After Startup | sgp30ebbrE20.b1 |
D030712.11 | SGP/EBBR/E2 - 6 Month Checks | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D030712.20 | SGP/EBBR/E19 - 6 Month Checks | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D030712.21 | SGP/EBBR/E20 - 6 Month Checks | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D030712.22 | SGP/EBBR/E22 - 6 Month Checks | sgp30ebbrE22.b1, sgp5ebbrE22.b1, sgp15ebbrE22.b1 |
D030712.6 | SGP/EBBR/E2 - Soil Heat Flow #2 Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D030712.7 | SGP/EBBR/E2 - Data All Zeros | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D030712.8 | SGP/EBBR/E2 - Bottom RH Incorrect | sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D030725.1 | SGP/EBBR/E2 - Soil Heat Flow #1 Incorrect | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D030728.1 | SGP/EBBR/E2 - Soil Heat Flow #3 Spike | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D030729.4 | SGP/EBBR/E22 - AEM Hung Inbetween Home Positions | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D030916.2 | SGP/EBBR/E22 - AEM Home Signals Too High | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D030917.15 | SGP/EBBR/E2 - Water in Net Radiometer, Surface Fluxes Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D030919.10 | SGP/EBBR/E19 - Water in Net Radiometer; Surface Fluxes are Incorrect | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D030919.4 | SGP/EBBR/E2 - 15 and 30 Minute Data are Zeros | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D030919.5 | SGP/EBBR/E2 - Soil Heat #1 Offscale | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D030922.6 | SGP/EBBR/E19 - Tair Right Offscale | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D031029.1 | SGP/EBBR/E20 - Fuse Blown in AEM | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D031029.2 | SGP/EBBR/E20 - Reprocess: Soil Temperature Probe #1 Measurements Spiked | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D031031.7 | SGP/EBBR/E20 - Water in Net Radiometer, Surface Fluxes Incorrect | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D031031.8 | SGP/EBBR/E22 - Water in Net Radiometer, Surface Fluxes Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D031110.8 | SGP/EBBR/E19 - Battery Voltage Too Low, Most Measurements Incorrect | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
D031117.2 | SGP/EBBR/E19 - AEM Stuck In One Position, Surface Fluxes Incorrect | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D031124.11 | SGP/EBBR/E19 - Data Missing During Recalibration Changeout | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp30baebbrE19.c1, sgpebbrE19.00, sgpebbrE19.01 |
D031204.17 | SGP/EBBR/E19 - 6 Month Checks | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D031204.18 | SGP/EBBR/E19 - 6 Month Checks | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D031204.19 | SGP/EBBR/E20 - 6 Month Checks | sgp5ebbrE20.b1, sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D031204.2 | SGP/EBBR/E19 - Data All Zeros | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D031204.20 | SGP/EBBR/E22 - 6 Month Checks | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
D031204.4 | SGP/EBBR/E2 - 6 Month Checks | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
D031208.5 | SGP/EBBR/E20 - Wind Direction Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031211.5 | SGP/EBBR/E20 - Pressure Sensor Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031222.10 | SGP/EBBR/E2 - All Data Zero After Logger Restart | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D031222.11 | SGP/EBBR/E2 - Net Radiometer Iced Over During Storm | sgp30ebbrE2.b1, sgp15ebbrE2.b1, sgp5ebbrE2.b1 |
D031222.20 | SGP/EBBR/E20 - Wind Speed Sensor Frozen By Ice Storm | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D031222.21 | SGP/EBBR/E22 - Wind Speed Sensor Frozen By Ice Storm | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D031222.22 | SGP/EBBR/E22 - Wind Direction Sensor Frozen By Ice Storm | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D040106.1 | SGP/EBBR/E19 - Wind Speed Sensor Frozen Stopped by Ice Storm | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040206.4 | SGP/EBBR/E19 - Low Battery Voltage Caused Incorrect Data | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040303.2 | SGP/EBBR/E22 - Wind Speed Sensor Bearings Worn | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D040304.19 | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D040304.20 | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040304.21 | SGP/EBBR/E22 - Wind Speed Frozen Stopped By Ice | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D040304.22 | SGP/EBBR/E22 - Wind Direction Frozen Stopped By Ice | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D040304.26 | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040304.5 | SGP/EBBR/E2 - Wind Speed Frozen Stopped By Ice | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D040407.2 | SGP/EBBR/E19 - Reprocess: Incorrect Net Rad Calibration Coefficient | sgp30baebbrE19.c1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040505.1 | SGP/EBBR/E2 - Soil Heat Flow #1 Spikes Down | sgp30ebbrE2.b1 |
D040507.2 | SGP/EBBR/E20 - Left Air Temperature Incorrect | sgp15ebbrE20.b1, sgp30baebbrE20.c1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040525.3 | SGP/EBBR/E19 - Metadata errors | sgp15ebbrE19.b1, sgp30baebbrE19.c1, sgp30ebbrE19.b1 |
D040525.4 | SGP/EBBR/E19 - Metadata errors | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040608.7 | SGP/EBBR/E19 - AEM Hung Inbetween Home Positions | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D040706.2 | SGP/EBBR/E22 - Net Radiation Incorrect | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D040722.1 | SGP/EBBR/E20 - Wind Direction Stuck at 100 Degrees | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040723.3 | SGP/EBBR/E22 - Water In Net Radiometer | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D040813.2 | SGP/EBBR/E20 - AEM Failure | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D040915.3 | SGP/EBBR/E2 - Net Radiometer Dome Broken, Reducing Net Radiation Measurement, Fluxes Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D040915.7 | SGP/EBBR/E20 - Soil Heat Flow #3 and Soil Temperature #3 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D041006.3 | SGP/EBBR/E20 - All Soil Measurements Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D041014.2 | SGP/EBBR/E2 - Soil Heat Flow Sensor #2 Bad | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D041222.15 | SGP/EBBR/E19 - 6 Month Checks | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D041222.16 | SGP/EBBR/E20 - 6 Month Checks | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D041222.17 | SGP/EBBR/E22 - 6 Month Checks | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
D041222.3 | SGP/EBBR/E20 - Soil Moisture #4 and Soil Temperature #4 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D041222.6 | SGP/EBBR/E2 - 6 Month Checks | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D041223.1 | SGP/EBBR/E20 - Soil Heat Flow #4 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D050206.13 | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050206.14 | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice Storm | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D050206.15 | SGP/EBBR/E22 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D050206.4 | SGP/EBBR/E2 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D050207.1 | SGP/EBBR/E2 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D050207.10 | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D050207.11 | SGP/EBBR/E22 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D050207.9 | SGP/EBBR/E19 - Wind Direction Frozen Stopped By Ice Storm | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
D050215.20 | SGP/EBBR/E19 - Wind Speed Constant | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
D050215.21 | SGP/EBBR/E22 - Wind Speed Frozen Stopped By Ice | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D050215.22 | SGP/EBBR/E22 - Wind Direction Frozen Stopped By Ice | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D050215.7 | SGP/EBBR/E2 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D050215.8 | SGP/EBBR/E2 - Wind Direction Frozen Stopped By Ice | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D050323.2 | SGP/EBBR/E22 - Net Radiation Too Low - Top Dome Broken | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D050324.2 | SGP/EBBR/E19 - Reprocess: Negative Net Rad calibrations | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050404.1 | SGP/EBBR/E20 - Wrong Datalogger Program Installed | sgp30ebbrE20.b1 |
D050404.4 | SGP/EBBR/E20 - Temp. of thum_left Incorrect At Times | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D050624.3 | SGP/EBBR/E19 - Net Radiation Incorrect - Cable Chewed by Rodents | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D050719.12 | SGP/EBBR/E19 - Improved EBBR CR10 Program | sgp30ebbrE19.b1 |
D050719.13 | SGP/EBBR/E20 - Improved EBBR CR10 Program | sgp30ebbrE20.b1 |
D050719.14 | SGP/EBBR/E22 - Improved EBBR CR10 Program | sgp30ebbrE22.b1 |
D050719.4 | SGP/EBBR/E2 - Improved EBBR CR10 Program | sgp30ebbrE2.b1 |
D050922.2 | SGP/EBBR/E20 - Soil Temperature and Soil Moisture #4 Measurements Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D051106.1 | SGP/EBBR/E2 - Net Radiation Incorrect; Latent and Sensible Heat Fluxes Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D051106.13 | SGP/EBBR/E22 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D051106.18 | SGP/EBBR/E2 - Average Soil Heat Flux Incorrect | sgp30ebbrE2.b1 |
D051106.27 | SGP/EBBR/E19 - Average Soil Heat Flux Incorrect | sgp30ebbrE19.b1 |
D051106.28 | SGP/EBBR/E20 - Average Soil Heat Flux Incorrect | sgp30ebbrE20.b1 |
D051106.29 | SGP/EBBR/E22 - Average Soil Heat Flux Incorrect | sgp30ebbrE22.b1 |
D051112.1 | SGP/EBBR/E19 - metadata corrections | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D051112.2 | SGP/EBBR/E2 - metadata corrections | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D051112.7 | SGP/EBBR/E20 - metadata corrections | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D051112.8 | SGP/EBBR/E22 - metadata corrections | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D051214.2 | SGP/EBBR/E19 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D051214.3 | SGP/EBBR/E19 - Incorrect Sensible and Latent Heat Fluxes | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
D060110.2 | SGP/EBBR/E2 - Sensible and Latent Heat Fluxes Incorrect | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
D060111.13 | SGP/EBBR/E20 - Data Incorrect During J-Panel Replacement | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D060112.1 | SGP/EBBR/E22 - Sensible and Latent Heat Fluxes Incorrect | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
D060428.4 | SGP/EBBR/E22 - Fluxes Incorrect When Soil Heat Flow #3 Out of Range | sgp30ebbrE22.b1 |
D060501.2 | SGP/EBBR/E2 - Wind Speed Sensor Frozen Stopped | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D060501.22 | SGP/EBBR/E20 - Suspect Measurements | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D060501.25 | SGP/EBBR/E22 - Wind Speed Sensor Frozen Stopped | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D060622.6 | SGP/EBBR/E20 - Net Radiation, Fluxes Too Large | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D060921.8 | SGP/EBBR/E22 - Net Radiation and Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D061106.5 | SGP/EBBR/E22 - Soil Heat Flow #4 Incorrect - Sensible and Latent Heat Fluxes Sometimes Affected | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D061114.9 | SGP/EBBR/E19 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE19.b1 |
D061220.1 | SGP/EBBR/E2 - Wind Direction Dependency of Surface Fluxes and General Data Quality Information | sgp30ebbrE2.b1 |
D061220.11 | SGP/EBBR/E19 - Wind Direction Dependency of Surface Fluxes and General Data Quality Information | sgp30ebbrE19.b1 |
D061220.12 | SGP/EBBR/E20 - Wind Direction Dependency of Surface Fluxes and General Data Quality Information | sgp30ebbrE20.b1 |
D061220.13 | SGP/EBBR/E22 - Wind Direction Dependency of Surface Fluxes and General Data Quality Information | sgp30ebbrE22.b1 |
D070208.2 | SGP/EBBR/E2 - Missing data | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp30baebbrE2.c1 |
D070208.3 | SGP/EBBR/E2 - Missing data | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D070215.2 | SGP/EBBR/E2 - Windspeed sensor failure | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D070426.1 | SGP/EBBR/E22 - Wind Direction Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D070716.2 | SGP/EBBR/E20 - Reprocess: Wind Direction 20 Degrees Low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D070815.6 | SGP/EBBR/E22 - H and LE Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D071115.1 | SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D080410.2 | SGP/EBBR/E20 - Wind Direction 50 Degrees High | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D080523.2 | SGP/EBBR/E2 - Net Radiation and Fluxes Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D080527.2 | SGP/EBBR/E19 - Sensible and latent heat flux and net radiation incorrect | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
D080616.3 | SGP/EBBR/E2 - AEM Ventilator Dangling - Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D080902.1 | SGP/EBBR/E20 - Wind Direction Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D090313.16 | SGP/EBBR/E20 - Wind Speed Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D090313.4 | SGP/EBBR/E19 - Wind Speed Incorrect | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
D090313.6 | SGP/EBBR/E22 - Wind Speed Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
D090414.1 | SGP/EBBR/E20 - Wind Direction Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D091001.2 | SGP/EBBR/E2 - Low Supply Voltage | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
D980117.1 | SGP/EBBR/E22 - Reprocess: E22 Soil Moisture Values Off End of Calibration at High Soil Moistures | sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/31/2000 | 2245 | 02/02/2000 | 1640 |
Subject: | SGP/EBBR - EBBR E19 Wind Speed Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The anemometer cups were frozen stalled during the period. The following values were therefore incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/30/1999 | 0700 | 02/09/2000 | 1715 |
Subject: | SGP/EBBR - EBBR E20 Right Air Temperature Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The right air temperature (thermocouple) output was frequently offscale. Examination of the 15 minute data will clearly show which times are affected during the period. The affected data are: 5 minute: tair_top, tair_bot 15 minute: tair_r 30 minute: tair_top, tair_bot, bowen, h, e |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/23/2000 | 1935 | 02/23/2000 | 2000 |
Subject: | SGP/EBBR - EBBR E20 Left Air Temperature Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Left air temperature (thermocouple) was incorrect during part of the period, thereby affecting top and bottom air temperature. The affected data and times are: 5 minute: tair_top (1935 GMT) 15 minute: tair_l (1945 GMT) 30 minute: tair_top, bowen, e, h (2000 GMT) |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/11/2000 | 0330 | 12/13/2000 | 0000 |
Subject: | SGP/EBBR/E2 - EBBR E2 Wind Speed Iced |
DataStreams: | sgp15ebbrE2.b1, sgp5ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data was incorrect. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/25/2000 | 1245 | 12/28/2000 | 1815 |
Subject: | SGP/EBBR/E19 - EBBR E19 Wind Speed Iced |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data is incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/25/2000 | 1545 | 12/28/2000 | 2145 |
Subject: | SGP/EBBR/E20 - EBBR E20 Wind Speed Iced |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data is incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/25/2000 | 1315 | 12/27/2000 | 2015 |
Subject: | SGP/EBBR/E22 - EBBR E22 Wind Speed Iced |
DataStreams: | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data is incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/30/2000 | 1600 | 03/30/2000 | 1605 |
Subject: | SGP/EBBR/E2 - E2 EBBR Most Data Incorrect |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | After logger replacement, most data was incorrect for the next timestamp. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/25/2000 | 1440 | 05/25/2000 | 1505 |
Subject: | SGP/EBBR/E2 - E2 EBBR Data Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The data was incorrect for a period after logger replacement. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/30/2000 | 1635 | 04/27/2000 | 1605 |
Subject: | SGP/EBBR/E2 - E2 EBBR Ts4 and SM4 Bouncing Around |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Ts4 and SM4 values bounced around in an unnatural way. The indicated data during the period indicated was incorrect. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/15/2000 | 0230 | 07/15/2000 | 1405 |
Subject: | SGP/EBBR/E2 - E2 EBBR Ts2 Incorrect |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Ts2 data and quantities derived from it were incorrect for the indicated period. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/28/2000 | 1300 | 08/31/2000 | 1505 |
Subject: | SGP/EBBR/E2 - E2 EBBR Wind Direction Incorrect |
DataStreams: | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The wind direction values were 135 degrees (an indication of an electronics failure in the sensor), 0 degrees, or 359 degrees during the indicated period, and were incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/18/2001 | 1700 | 01/18/2001 | 1705 |
Subject: | SGP/EBBR/E2 - E2 EBBR Data Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | Most of the data values were incorrect during the indicated time period, for an unknown reason. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/26/2000 | 1815 | 01/04/2001 | 1405 |
Subject: | SGP/EBBR/E2 - E2 EBBR Low Battery Condition |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | All data should be considered to be incorrect when battery voltage is 10.4 volts or less. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/25/2000 | 2245 | 09/28/2000 | 1450 |
Subject: | SGP/EBBR/E2 - E2 EBBR Left Aspirator Fan Stopped |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The indicated data was incorrect while the left aspirator fan was not operating. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/29/2000 | 0100 | 12/01/2000 | 0105 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/02/2000 | 2330 | 12/03/2000 | 0635 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/2000 | 1300 | 12/04/2000 | 1005 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/05/2000 | 0500 | 12/07/2000 | 0005 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/07/2000 | 0130 | 12/07/2000 | 0135 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/07/2000 | 0930 | 12/07/2000 | 1535 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/10/2000 | 1000 | 12/11/2000 | 1635 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2000 | 0600 | 12/31/2000 | 2250 |
Subject: | SGP/EBBR/E2 - E2 EBBR AEM Stuck In One Position |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | The indicated data was incorrect while the AEM was was not operating properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/05/2000 | 2000 | 04/05/2000 | 2001 |
04/05/2000 | 1900 | 04/05/2000 | 1901 |
Subject: | SGP EBBR E22 - E22 EBBR Data Incorrect During Logger Replacement |
DataStreams: | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.00 |
Description: | The data was incorrect during replacement of the logger. |
Measurements: | sgp5ebbrE22.00:
sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/08/2000 | 1800 | 10/16/2000 | 0231 |
05/10/2000 | 2000 | 06/11/2000 | 0531 |
04/21/2000 | 1900 | 04/27/2000 | 1031 |
Subject: | SGP EBBR E22 - E22 EBBR Soil Moisture Lower Than Measurement Capability |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | The indicated measurements were incorrect because soil moisture dropped below (sometimes even negative) the ability of the probes to measure it. |
Measurements: | sgp30ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/16/2000 | 0235 | 10/22/2000 | 0316 |
Subject: | SGP EBBR E22 - E22 EBBR Soil Moisture #3 Lower Than Can Be Measured |
DataStreams: | sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | The soil moisture was too low to be measured correctly by probe #3. |
Measurements: | sgp30ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/16/2000 | 0130 | 10/18/2000 | 1841 |
Subject: | SGP EBBR E22 - E22 EBBR Net Radiation Incorrect |
DataStreams: | sgp30ebbrE22.b1, sgp15ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Water inside the domes of the net radiometer caused measurements from it to be incorrect. Calculated latent and sensible heat fluxes were therefore incorrect also. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/02/2000 | 1500 | 12/08/2000 | 1946 |
Subject: | SGP EBBR E19 - E19 EBBR Left Aspirator Housing Off |
DataStreams: | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The left aspirator housing fell off and thus the indicated measurements are incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/07/1999 | 0000 | 02/24/2000 | 1601 |
Subject: | SGP EBBR E19 - E19 EBBR Left Air Temperature Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | A bad capacitor on the J-panel caused left air temperature, and thus other measurements to be incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/09/2000 | 1630 | 03/09/2000 | 1701 |
Subject: | SGP EBBR E19 - E19 EBBR Data Incorrect During J-panel Replacement |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | The indicated data was incorreect during a J-panel replacement. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2000 | 2030 | 12/13/2000 | 0731 |
Subject: | SGP EBBR E19 - E19 EBBR Wind Direction Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The wind direction sensor was frozen stopped during the indicated period. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/24/1999 | 0445 | 01/25/2001 | 1531 |
Subject: | SGP EBBR E19 - E19 EBBR Soil Heat Flow #1 Sign Reversed |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The sign was reversed (heat flow plate #1 was installed upside down), causing incorrect measurements, as indicated. The average soil heat flow can be recalculated by using an average of soil sensor sets 2-5. The recalculated average soil heat flow can then be used to recalculate latent and sensible heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/06/2000 | 1930 | 03/06/2000 | 2031 |
01/06/2000 | 2000 | 03/06/2000 | 1901 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Heat Flow #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Soil Heat Flow #3 was incorrect during the indicated periods. Average soil heat flux, latent heat flux, and sensible heat flux were therefore also incorrect. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/22/2000 | 0000 | 05/22/2000 | 0000 |
Subject: | SGP EBBR E20 - E20 EBBR Right Air T Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The right air temperature probe was incorrect while connections for it were checked. Bowen ratio, sensible heat flux, and latent heat flux were incorrect as a result. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/02/2000 | 2345 | 02/21/2001 | 1946 |
Subject: | SGP EBBR E20 - E20 EBBR Right Air T Incorrect |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The right air temperature probe was incorrect frequently. Inspection of the right air temperature data will quickly show where it went offscale. Bowen ratio, sensible heat flux, and latent heat flux were incorrect as a result. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2000 | 1930 | 11/01/2000 | 1931 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Temperatures Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | All soil temperatures were incorrect for the indicated period. Latent and sensible heat fluxes were therefore incorrect also. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/15/2000 | 2031 | 11/15/2000 | 2101 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect During STP #3 Replacement |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00 |
Description: | All data was incorrect during replacement of soil temperature probe #3. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/29/2000 | 1831 | 11/29/2000 | 1901 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect After Program Restart |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00 |
Description: | All data was incorrect after a datalogger program restart. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/29/2000 | 1930 | 11/29/2000 | 1931 |
Subject: | SGP EBBR E20 - E20 EBBR Some Data Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Quantities requiring a starting value were incorrect; sensible and latent heat fluxes were therefore incorrect also. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/17/2000 | 2001 | 05/17/2000 | 2031 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00 |
Description: | Data was incorrect right after a datalogger upgrade. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/20/2000 | 1930 | 08/02/2000 | 0331 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | The data was incorrect because battery voltage was low. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/04/2000 | 1930 | 10/04/2000 | 1931 |
Subject: | SGP EBBR E20 - E20 EBBR Net Radiation Data Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The net radiation data was incorrect while the top dome was being replaced. Sensible and latent heat fluxes are therefore also incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2001 | 0000 | 05/07/2001 | 2356 |
05/21/2001 | 0000 | 05/21/2001 | 2356 |
Subject: | SGP EBBR E19 - E19 EBBR Soil Temperature 3 Intermittenmtly Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Soil Temperature # 3 was incorrect at times during these periods. Compare G3 with G1, G2, G4, and G5 to determine when TS3 was incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 04/01/2001 | 1631 |
Subject: | SGP EBBR E19 - E19 EBBR TS3 Intermittent Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Soil Temperature probe #3 was intermittently incorrect. Examine the data and compare G3 with G1-2 and G4-5 to see when TS3 is incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2001 | 0300 | 03/01/2001 | 1651 |
Subject: | SGP EBBR E19 - E19 EBBR Wind Speed Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The wind speed sensor was iced stopped for a while on this day. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/26/2001 | 1445 | 04/26/2001 | 1536 |
11/18/2001 | 1535 | 11/18/2001 | 1631 |
Subject: | SGP EBBR E2 - E2 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | The indicated data was incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/03/2001 | 1413 | 10/03/2001 | 1506 |
04/19/2001 | 1700 | 04/19/2001 | 2001 |
Subject: | SGP EBBR E19 - E19 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/04/2001 | 1700 | 04/04/2001 | 1736 |
10/17/2001 | 1500 | 10/17/2001 | 1601 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2001 | 1800 | 10/10/2001 | 1857 |
04/18/2001 | 1715 | 04/18/2001 | 1821 |
Subject: | SGP EBBR E22 - E22 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2000 | 2300 | 11/15/2000 | 2031 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The indicated measurements were incorrect while soil temperature probe #3 was not working. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/07/2001 | 2000 | 03/07/2001 | 2001 |
Subject: | SGP EBBR E22 - E22 EBBR 30 Minute Data Incorrect After Missing Data |
DataStreams: | sgp30ebbrE22.b1 |
Description: | Complete soil temperature information is not available when the data is missing for the previous half hour. Since soil temperature difference with time cannot be computed properly, the selected calculated quantities are incorrect. |
Measurements: | sgp30ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/21/2001 | 2000 | 03/07/2001 | 1901 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Heat Flow #2 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Broken leads for SHF #2 caused measurements from it to be incorrect during the indicated period. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/31/2001 | 1115 | 03/31/2001 | 1401 |
03/30/2001 | 0615 | 03/30/2001 | 1431 |
Subject: | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Incorrect Data |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Some measurements were incorrect because the battery voltage was low. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/23/2001 | 1045 | 04/23/2001 | 1331 |
04/06/2001 | 1115 | 04/06/2001 | 1501 |
04/07/2001 | 0345 | 04/07/2001 | 1401 |
04/02/2001 | 1245 | 04/02/2001 | 1701 |
04/03/2001 | 0215 | 04/03/2001 | 1501 |
Subject: | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The indicated data was incorrect because the battery voltage was low. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/15/2001 | 1500 | 10/17/2001 | 0201 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | During the indicated period, TS #3 was large negative or positive or offscale. Average soil heat flow, sensible heat flux, and latent heat flux were incorrect when TS #3 was incorrect. Inspect the 15 and 30 minute TS #3 data to determine the times of incorrect data. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2001 | 0000 | 02/22/2001 | 0531 |
03/07/2001 | 1805 | 03/07/2001 | 1901 |
03/01/2001 | 1230 | 03/01/2001 | 1231 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Heat Flow #4 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The SHF #4 produced large negative values during much of the period because of a broken lead wire. Inspect the data to determine the times of incorrect SHF #4 values. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/15/2001 | 0830 | 02/15/2001 | 1531 |
02/09/2001 | 0330 | 02/11/2001 | 2001 |
02/16/2001 | 1431 | 02/16/2001 | 1901 |
02/19/2001 | 0900 | 03/24/2001 | 2301 |
02/01/2001 | 0230 | 02/02/2001 | 1601 |
02/16/2001 | 2100 | 02/18/2001 | 1831 |
Subject: | SGP/EEBR/E2 - AEM Stopped In One Position |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | All gradient related measurements, including sensible and latent heat flux and bowen ratio, are incorrect. The AEM kept stopping in the home30 position (home signal about 23). |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/30/2001 | 0345 | 09/08/2001 | 1701 |
07/05/2001 | 1800 | 07/30/2001 | 0201 |
09/13/2001 | 0530 | 09/13/2001 | 1531 |
09/13/2001 | 1900 | 09/27/2001 | 1416 |
06/20/2001 | 1646 | 07/04/2001 | 1101 |
10/02/2001 | 0945 | 01/12/2002 | 0001 |
04/26/2001 | 1505 | 06/07/2001 | 1501 |
Subject: | SGP/EEBR/E2 - AEM Stopped In One Position |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The AEM kept stopping in one of three positions, none of which allow sensible heat flux, latent heat flux, or Bown ratio to be calculated correctly. These and the gradient measurements are incorrect for the period indicated. The AEM stopped in either the home15 position (home signal about 53), the home 30 position (home signal about 23), or inbetween these two (home signal 1 to 2). |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/08/2001 | 1745 | 02/10/2001 | 1630 |
Subject: | SGP/EEBR/E2 - Wind Direction Frozen |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The wind direction sensor froze stopped for the indicated period of time. The indicated measurements are incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/08/2001 | 1745 | 02/11/2001 | 1731 |
Subject: | SGP/EEBR/E2 - Wind Speed Sensor Frozen |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The wind speed sensor was frozen stopped. The indicated measurements were incorrect. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/24/2001 | 0700 | 03/24/2001 | 1501 |
03/24/2001 | 0300 | 03/24/2001 | 0431 |
03/26/2001 | 0430 | 03/26/2001 | 1531 |
03/30/2001 | 0645 | 03/30/2001 | 1431 |
03/15/2001 | 1400 | 03/15/2001 | 1601 |
03/28/2001 | 0745 | 03/28/2001 | 1301 |
03/25/2001 | 0530 | 03/25/2001 | 1431 |
Subject: | SGP/EEBR/E2 - Soil Temperature #2 Incorrect |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Soil temperature #2 was intermittently incorrect. The cause is not yet known. The indicated other measurements were also incorrect because soil temperature #2 was used in the calculations of the quantities. Soil moisture (30 minute only) was affected because version 6 of the EBBR datalogger program used a multiplication of soil temperature and soil moisture as part of the adjustment of soil moisture for soil temperature. This was discovered to be a poor technique soon after it was implemented, but E2 will continue to use version 6 until a replacement EBBR unit is available. Changeout dates of the EBBR units can be found on the EBBR Instrument web page. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/03/2001 | 1100 | 05/03/2001 | 1901 |
05/24/2001 | 0330 | 05/24/2001 | 1431 |
05/01/2001 | 0415 | 05/02/2001 | 1301 |
05/07/2001 | 1045 | 05/09/2001 | 0301 |
05/21/2001 | 0330 | 05/21/2001 | 0801 |
05/22/2001 | 1830 | 05/23/2001 | 2001 |
06/15/2001 | 0900 | 06/15/2001 | 1131 |
05/01/2001 | 0115 | 05/01/2001 | 0231 |
05/05/2001 | 1730 | 05/06/2001 | 0401 |
06/19/2001 | 1215 | 06/19/2001 | 1331 |
05/06/2001 | 2015 | 05/07/2001 | 0831 |
05/12/2001 | 1815 | 05/13/2001 | 0130 |
05/22/2001 | 1700 | 05/22/2001 | 1701 |
06/20/2001 | 0445 | 06/20/2001 | 0701 |
05/20/2001 | 0115 | 05/20/2001 | 0231 |
05/22/2001 | 0130 | 05/22/2001 | 1531 |
05/27/2001 | 0930 | 05/27/2001 | 1431 |
05/21/2001 | 0945 | 05/21/2001 | 1331 |
06/02/2001 | 1145 | 06/02/2001 | 1231 |
06/21/2001 | 1500 | 06/21/2001 | 1531 |
05/04/2001 | 1600 | 05/04/2001 | 1631 |
05/19/2001 | 1330 | 05/19/2001 | 2301 |
05/21/2001 | 1500 | 05/21/2001 | 1931 |
06/21/2001 | 1100 | 06/21/2001 | 1401 |
Subject: | SGP/EBBR/E2 - Reprocess: E2 EBBR Soil Temperature #2 Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | Soil Temperature #2 was intermittently incorrect. The cause is unknown. The indicated measurements that are calculated using soil temperature are also incorrect. Soil moisture #2 (30 minute only) was also affected because version 6 of the EBBR datalogger program uses a multiplication of soil temperature and soil moisture as part of the adjustment of soil moisture for soil temperature. This was discovered to be a poor technique soon after it was implemented, but E2 will continue to use version 6 until a replacement EBBR unit is available. When soil temperature #2 is large negative, soil moisture #2 is often twice as large as it should be. EBBR unit changeout dates are listed on the EBBR instrument web page. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/22/2001 | 1445 | 06/22/2001 | 1501 |
07/19/2001 | 1045 | 07/19/2001 | 1431 |
10/31/2001 | 1415 | 10/31/2001 | 1731 |
12/21/2001 | 2000 | 12/21/2001 | 2031 |
01/05/2002 | 1730 | 01/05/2002 | 2301 |
06/26/2001 | 0845 | 06/27/2001 | 0331 |
07/12/2001 | 1115 | 07/12/2001 | 1531 |
07/19/2001 | 0200 | 07/19/2001 | 0301 |
07/21/2001 | 1730 | 07/21/2001 | 1801 |
08/04/2001 | 1715 | 08/04/2001 | 1831 |
10/20/2001 | 1545 | 10/20/2001 | 1631 |
11/05/2001 | 1600 | 11/05/2001 | 1901 |
12/17/2001 | 1345 | 12/17/2001 | 1531 |
12/22/2001 | 1100 | 12/22/2001 | 1331 |
01/11/2002 | 1530 | 01/11/2002 | 1831 |
06/22/2001 | 1100 | 06/22/2001 | 1331 |
07/12/2001 | 0300 | 07/12/2001 | 0401 |
07/18/2001 | 0815 | 07/18/2001 | 0901 |
09/28/2001 | 1830 | 09/28/2001 | 1831 |
11/11/2001 | 1430 | 11/11/2001 | 1531 |
12/22/2001 | 0800 | 12/22/2001 | 1001 |
12/28/2001 | 2345 | 12/29/2001 | 0031 |
01/07/2002 | 0930 | 01/07/2002 | 1031 |
06/27/2001 | 0545 | 06/30/2001 | 1701 |
10/16/2001 | 1915 | 10/16/2001 | 2001 |
11/02/2001 | 1530 | 11/02/2001 | 1731 |
12/27/2001 | 1800 | 12/27/2001 | 1901 |
01/08/2002 | 1615 | 01/08/2002 | 2101 |
07/18/2001 | 0230 | 07/18/2001 | 0301 |
10/16/2001 | 2315 | 10/17/2001 | 0001 |
12/06/2001 | 1715 | 12/06/2001 | 2331 |
07/19/2001 | 0900 | 07/19/2001 | 0931 |
08/03/2001 | 1500 | 08/04/2001 | 0101 |
11/01/2001 | 0115 | 11/01/2001 | 0131 |
12/28/2001 | 1830 | 12/28/2001 | 1931 |
07/12/2001 | 0500 | 07/12/2001 | 0531 |
07/20/2001 | 1445 | 07/20/2001 | 1931 |
11/10/2001 | 1730 | 11/10/2001 | 1901 |
12/27/2001 | 2030 | 12/28/2001 | 0031 |
07/04/2001 | 1130 | 07/05/2001 | 0231 |
07/14/2001 | 0230 | 07/14/2001 | 1501 |
07/19/2001 | 0545 | 07/19/2001 | 0801 |
09/28/2001 | 1930 | 09/29/2001 | 0001 |
11/11/2001 | 1015 | 11/11/2001 | 1201 |
12/22/2001 | 0115 | 12/22/2001 | 0401 |
01/11/2002 | 0115 | 01/11/2002 | 0201 |
Subject: | SGP/EBBR/E2 - Reprocess: E2 EBBR Soil Temperature #2 Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | Soil Temperature #2 was intermittently incorrect. The cause is unknown. The indicated measurements that are calculated using soil temperature are also incorrect. Soil moisture #2 (30 minute only) was also affected because version 6 of the EBBR datalogger program uses a multiplication of soil temperature and soil moisture as part of the adjustment of soil moisture for soil temperature. This was discovered to be a poor technique soon after it was implemented, but E2 will continue to use version 6 until a replacement EBBR unit is available. When soil temperature #2 is large negative, soil moisture #2 is often twice as large as it should be. EBBR unit changeout dates are listed on the EBBR instrument web page. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/13/2001 | 0530 | 04/13/2001 | 1631 |
04/23/2001 | 0515 | 04/24/2001 | 0001 |
04/16/2001 | 0515 | 04/16/2001 | 2301 |
04/25/2001 | 0215 | 04/25/2001 | 0331 |
04/30/2001 | 0615 | 04/30/2001 | 1601 |
04/30/2001 | 1745 | 04/30/2001 | 2101 |
04/14/2001 | 0745 | 04/14/2001 | 1501 |
04/19/2001 | 0615 | 04/19/2001 | 1601 |
04/16/2001 | 0245 | 04/16/2001 | 0301 |
04/30/2001 | 0130 | 04/30/2001 | 0401 |
04/17/2001 | 0145 | 04/17/2001 | 0931 |
04/01/2001 | 1145 | 04/01/2001 | 1301 |
04/15/2001 | 1445 | 04/15/2001 | 1831 |
04/17/2001 | 1545 | 04/18/2001 | 1601 |
04/12/2001 | 0130 | 04/12/2001 | 1331 |
04/15/2001 | 0915 | 04/15/2001 | 1231 |
04/25/2001 | 1030 | 04/25/2001 | 1331 |
04/29/2001 | 1500 | 04/29/2001 | 1601 |
Subject: | SGP/EBBR/E2 - Reprocess: E2 EBBR Soil Temperature #2 Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | Soil Temperature #2 was intermittently incorrect. The cause is unknown. The indicated measurements that are calculated using soil temperature are also incorrect. Soil moisture #2 (30 minute only) was also affected because version 6 of the EBBR datalogger program uses a multiplication of soil temperature and soil moisture as part of the adjustment of soil moisture for soil temperature. This was discovered to be a poor technique soon after it was implemented, but E2 will continue to use version 6 until a replacement EBBR unit is available. When soil temperature #2 is large negative, soil moisture #2 is often twice as large as it should be. EBBR unit changeout dates are listed on the EBBR instrument web page. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/16/2002 | 1430 | 05/16/2002 | 1501 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2002 | 1910 | 05/01/2002 | 1946 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/15/2002 | 1810 | 05/15/2002 | 1846 |
Subject: | SGP/EBBR/E22 - 6 Month Checks |
DataStreams: | sgp30ebbrE22.b1, sgp5ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2002 | 0000 | 01/17/2002 | 1631 |
Subject: | SGP/EBBR/E2 - AEM Hung |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The automatic exchange mechanism hung, thereby making a number of measurements incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2002 | 0330 | 03/01/2002 | 1701 |
Subject: | SGP/EBBR/E2 - Wind Direction Incorrect |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The wind direction was always 65 to 90 degrees and sigma direction was near zero; the data is incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/14/2002 | 1515 | 02/14/2002 | 1531 |
01/15/2002 | 0645 | 01/15/2002 | 1701 |
Subject: | SGP/EBBR/E2 - Reprocess: Soil Temperature #2 Incorrect |
DataStreams: | sgp30ebbrE2.b1 |
Description: | The indicated measurements were incorrect because soil temperature #2 was incorrect. Average soil heat flow, sensible heat and latent heat can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g3 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/15/2002 | 1900 | 01/15/2002 | 1901 |
Subject: | SGP/EBBR/E2 - Data Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp5ebbrE2.00 |
Description: | The indicated measurements were zeros (30 minute) or incorrect (5 and 15 minute) the half hour after the recalibration unit was installed. |
Measurements: | sgp5ebbrE2.00:
sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/28/2002 | 1615 | 02/28/2002 | 1646 |
Subject: | SGP/EBBR/E2 - 6 Month Checks |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/23/2002 | 1500 | 05/23/2002 | 1531 |
Subject: | SGP/EBBR/E2 - 6 Month Checks |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/08/2002 | 1630 | 02/21/2002 | 1601 |
Subject: | SGP/EBBR/E19 - Reprocess: Soil Heat Flow #3 Incorrect |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Soil heat flow 3 was incorrect, with values too large positive and too small negative. Since the calibration in the program is the one supplied by the vendor, it appears that the calibration may be wrong. Average soil heat flow, sensible heat flux and latent heat flux can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g2 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2001 | 0000 | 06/30/2002 | 2356 |
Subject: | SGP/EBBR/E19 - Reprocess: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Soil Temperature 3 was incorrect for the period indicated, causing average soil flow, latent heat flux, and sensible heat flux to be incorrect also. Average soil heat flow, sensible heat flux, and latent heat flux can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g2 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/08/2002 | 0430 | 04/08/2002 | 0431 |
05/19/2002 | 0400 | 05/19/2002 | 0401 |
Subject: | SGP/EBBR/E19 - Most Measurements Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | Most measurements were incorrect for the indicated periods. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/27/2002 | 1500 | 06/27/2002 | 1501 |
04/18/2002 | 1730 | 04/18/2002 | 1731 |
05/05/2002 | 1400 | 05/05/2002 | 1401 |
Subject: | SGP/EBBR/E19 - All Measurements Zero |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | Measurements are often zero the first period after a CR10 restart. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/29/2002 | 1830 | 05/29/2002 | 1831 |
04/24/2002 | 1600 | 04/24/2002 | 2201 |
05/29/2002 | 2000 | 05/29/2002 | 2001 |
06/15/2002 | 1900 | 06/15/2002 | 1901 |
05/25/2002 | 2200 | 05/25/2002 | 2231 |
05/25/2002 | 2100 | 05/25/2002 | 2101 |
05/29/2002 | 1730 | 05/29/2002 | 1731 |
05/29/2002 | 2130 | 05/29/2002 | 2131 |
05/30/2002 | 1500 | 05/30/2002 | 1501 |
Subject: | SGP/EBBR/E19 - Pressure Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The pressure measurement was incorrect. This is used to determine the Bowen ratio, thereby affecting the sensible and latent heat fluxes also. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/16/2002 | 2000 | 05/17/2002 | 0531 |
Subject: | SGP/EBBR/E19 - Measurements Incorrect After CR10 Replacement |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | Replacement of the CR10 datalogger caused most measurements to be incorrect, reason unknown. A different logger was installed at the end of the specified period and this resolved the problem. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/27/2002 | 0000 | 06/02/2002 | 1031 |
Subject: | SGP/EBBR/E19 - Low Battery Voltage |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp5ebbrE19.00 |
Description: | A battery voltage of less than 10.5 causes many of the sensors to produce incorrect measurements. The 15 minute data contains the battery voltage and should be used to determine whether the measurements are usable, based on battery voltage. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp5ebbrE19.00:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2002 | 1845 | 02/07/2002 | 1901 |
Subject: | SGP/EBBR/E22 - All Measurements Zero |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1, sgp5ebbrE22.00 |
Description: | The measurements are often all zero the first period after a CR10 restart, as occurred here. |
Measurements: | sgp5ebbrE22.00:
sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/17/2001 | 1230 | 01/09/2002 | 1531 |
04/21/2002 | 2000 | 05/29/2002 | 1831 |
02/14/2002 | 2015 | 02/16/2002 | 1531 |
01/09/2002 | 1545 | 01/12/2002 | 0001 |
02/08/2002 | 2145 | 02/14/2002 | 2001 |
02/28/2002 | 1030 | 03/06/2002 | 1901 |
02/17/2002 | 0415 | 02/20/2002 | 0531 |
01/12/2002 | 0515 | 01/15/2002 | 0031 |
02/20/2002 | 0815 | 02/20/2002 | 1831 |
02/16/2002 | 1945 | 02/17/2002 | 0001 |
02/08/2002 | 0845 | 02/08/2002 | 2031 |
Subject: | SGP/EBBR/E22 - AEM Hung or High Home Signals |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The automatic exchange mechanism hung some times and continued to switch at other times, although with high home signal values. If home signal values are not in the proper ranges, the gradient calculation is not performed properly by the CR10 program. Affected flux measurements cannot be recalculated. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/28/2001 | 2045 | 01/23/2002 | 1801 |
Subject: | SGP/EBBR/E20 - AEM Hung |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The automatic exchange mechanism frequently hung in one position. The home signals and automated qc in the netcdf data files indicate when this occurred. Bowen ratio, sensible heat flux, and latent heat flux are incorrect for this condition. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/06/2002 | 2130 | 02/07/2002 | 0331 |
11/28/2001 | 0045 | 11/28/2001 | 2031 |
Subject: | SGP/EBBR/E20 - Battery Voltage Low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | When the battery voltage is below 10.5 volts, most of the measurements are suspect. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2001 | 1605 | 11/28/2001 | 2031 |
Subject: | SGP/EBBR/E20 - Pressure Almost Constant |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During the indicated period the pressure went to an almost constant 102 to 105 kPa. This occurred after the replacement of another sensor. The incorrect pressure values affect the sensible and latent heat flux calculations. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2001 | 1915 | 12/12/2001 | 2031 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #3 Incorrect During Sensor Changeout |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #3 measurements were incorrect during it's replacement. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g5)/2 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) Note: during the time period referenced here, soil heat flow #4 and #2 were also incorrect. This quality information is documented in D020717.46, D020717.47 and D020726.1. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2002 | 1645 | 02/20/2002 | 1831 |
02/09/2002 | 0115 | 02/12/2002 | 0731 |
01/12/2002 | 0315 | 01/13/2002 | 2131 |
12/04/2001 | 0000 | 12/12/2001 | 1914 |
01/17/2002 | 0915 | 01/21/2002 | 0901 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 Has a Negative Offset |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #2 measurements had a negative offset. Negative values were too small and negative values occurred when positive values should have. This can occur when there is a poor wire connection or a J-panel over-voltage protection device has failed. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g3 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/24/2001 | 0532 | 12/27/2001 | 1901 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #4 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #4 was incorrect because it's wires were loose from the connection terminals. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g2 + g3 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/27/2001 | 1800 | 11/27/2001 | 1801 |
11/14/2001 | 1600 | 11/14/2001 | 1601 |
05/15/2002 | 1700 | 05/15/2002 | 1701 |
05/29/2002 | 1830 | 05/29/2002 | 1901 |
Subject: | SGP/EBBR/E20 - Measurements Zero |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | Most measurements were zero during the indicated periods. This often happens for the first reported data time after a CR10 datalogger restart. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/22/2002 | 2015 | 02/22/2002 | 2101 |
03/05/2002 | 2015 | 03/06/2002 | 0201 |
03/06/2002 | 1915 | 03/07/2002 | 1901 |
02/24/2002 | 0045 | 02/25/2002 | 0201 |
02/23/2002 | 1745 | 02/23/2002 | 1801 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil temperature 3 was incorrect during the indicated periods. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g2 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2002 | 1745 | 02/20/2002 | 1901 |
Subject: | SGP/EBBR/E20 - Measurements Incorrect During Sensor Changeout |
DataStreams: | sgp30ebbrE20.b1 |
Description: | The replacement of soil heat flow 2 caused the loss of initial soil temperature values used in the calculation of CES, G, C, ave_shf, bowen, e, and h. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/27/2001 | 1845 | 12/27/2001 | 1901 |
05/15/2002 | 1715 | 05/15/2002 | 1731 |
Subject: | SGP/EBBR/E20 - Measurements Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | Many measurements were incorrect because of the lack of an initial 15 minute value to use for gradient or soil change of energy storage calculations. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2001 | 2032 | 12/24/2001 | 0531 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 and #4 incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #2 measurements had a negative offset. Negative values were too small and negative values occurred when positive values should have. This can occur when there is a poor wire connection or a J-panel over-voltage protection device has failed. Soil heat flow #4 was incorrect because it's wires were loose from the connection terminals. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g3 + g5)/3 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE9.b1, sgp30ebbrE8.b1, sgp30ebbrE22.b1, sgp30ebbrE20.b1, sgp30ebbrE4.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE2.b1, sgp30ebbrE26.b1, sgp30ebbrE7.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30ebbrE2.b1:
sgp30ebbrE26.b1:
sgp30ebbrE9.b1:
sgp30ebbrE22.b1:
sgp30ebbrE13.b1:
sgp30ebbrE7.b1:
sgp30ebbrE18.b1:
sgp30ebbrE12.b1:
sgp30ebbrE4.b1:
sgp30ebbrE15.b1:
sgp30ebbrE19.b1:
sgp30ebbrE20.b1:
sgp30ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/1993 | 1200 | 06/18/2003 | 1159 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. (NOTE: The actual begin date of some of these data streams is as early as 7/4/93. This DQR applies to all 30m EBBR data.) |
Measurements: | sgp30ebbrE26.b1:
sgp30ebbrE9.b1:
sgp30ebbrE7.b1:
sgp30ebbrE4.b1:
sgp30ebbrE12.b1:
sgp30ebbrE15.b1:
sgp30ebbrE22.b1:
sgp30ebbrE13.b1:
sgp30ebbrE8.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2002 | 1600 | 11/14/2002 | 1630 |
Subject: | SGP/EBBR/E19 - Data Incorrect during 6 month checks |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/26/2002 | 1900 | 11/26/2002 | 1930 |
Subject: | SGP/EBBR/E20 - Data Incorrect during 6 month checks |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2002 | 1900 | 11/13/2002 | 1930 |
Subject: | SGP/EBBR/E22 - Data Incorrect during 6 month checks |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/07/2002 | 1600 | 11/07/2002 | 1630 |
Subject: | SGP/EBBR/E2 - Data Incorrect during 6 month checks |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/03/2002 | 1930 | 10/23/2002 | 0630 |
11/03/2002 | 1800 | 01/01/2003 | 0000 |
08/13/2002 | 0430 | 09/04/2002 | 1730 |
08/01/2002 | 1800 | 08/01/2002 | 1930 |
10/26/2002 | 1730 | 10/30/2002 | 2330 |
09/12/2002 | 1900 | 10/01/2002 | 1830 |
09/09/2002 | 1430 | 09/09/2002 | 1459 |
Subject: | SGP/EBBR/E2 - REPROCESS: Soil Heat Flow #2 Incorrect |
DataStreams: | sgp30ebbrE2.b1 |
Description: | Soil Heat Flow #2 was incorrect during these periods. See below for a work-around. |
Measurements: | sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/08/2002 | 1600 | 04/18/2002 | 1700 |
Subject: | SGP/EBBR/E19 - REPROCESS: Soil Heat Flow #3 Incorrect Calibration |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Soil Heat Flow #3 was incorrect during these periods. To use the measurements, multiply Soil Heat Flow #3 by 0.726. See below for a work-around. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/25/2002 | 2100 | 09/05/2002 | 1430 |
Subject: | SGP/EBBR/E19 - Water in Net Radiometer Dome |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiation measurement is incorrect. Measurements calculated using net radiation are also incorrect. No work-around is possible for this situation. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2002 | 1600 | 07/11/2002 | 1629 |
Subject: | SGP/EBBR/E19 - Incorrect data after power interruption |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Most measurements are suspect after a power outage, caused by replacement of the solar panel regulator. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2002 | 1500 | 07/11/2002 | 1529 |
Subject: | SGP/EBBR/E19 - Most Measurements Zero following Restart |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/24/2002 | 1430 | 07/24/2002 | 1500 |
Subject: | SGP/EBBR/E19 - REPROCESS: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Soil Temperature #3 was incorrect while electronic connections were being checked. The indicated measurements that are calculated using Soil Temperature #3 are also incorrect. See a work-around below. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/2002 | 0230 | 08/09/2002 | 0300 |
08/09/2002 | 0930 | 08/09/2002 | 1100 |
08/10/2002 | 0130 | 08/10/2002 | 0230 |
08/13/2002 | 2030 | 08/13/2002 | 2030 |
08/21/2002 | 1630 | 08/22/2002 | 1430 |
07/26/2002 | 0900 | 07/26/2002 | 0900 |
07/28/2002 | 0300 | 07/28/2002 | 0630 |
08/13/2002 | 2130 | 08/14/2002 | 0330 |
07/27/2002 | 0630 | 07/27/2002 | 0830 |
08/08/2002 | 1600 | 08/08/2002 | 1600 |
07/25/2002 | 0930 | 07/25/2002 | 1300 |
07/28/2002 | 0930 | 07/28/2002 | 1230 |
08/09/2002 | 0730 | 08/09/2002 | 0730 |
08/10/2002 | 1200 | 08/10/2002 | 1330 |
08/14/2002 | 1300 | 08/14/2002 | 1330 |
07/26/2002 | 1130 | 07/26/2002 | 1130 |
08/13/2002 | 0600 | 08/13/2002 | 0700 |
08/09/2002 | 1400 | 08/09/2002 | 1600 |
07/29/2002 | 0800 | 07/29/2002 | 0830 |
Subject: | SGP/EBBR/E19 - REPROCESS: Soil Heat Flow #1 Incorrect |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Soil Heat Flow #1 was incorrect during these periods. See below for a work-around. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/17/2002 | 1430 | 10/31/2002 | 1600 |
Subject: | SGP/EBBR/E19 - Pressure Low |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The barometric pressure sensor read about 10 mb low during this period because a lead from the sensor was loose or disconnected. The error does not affect any other measurements. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2002 | 1830 | 11/13/2002 | 1859 |
12/11/2002 | 1900 | 12/11/2002 | 1929 |
Subject: | SGP/EBBR/E20 - Data Zero following logger restarts |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/2002 | 1705 | 09/18/2002 | 1700 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #2 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #2 was incorrect, apparently from am loose wire after replacement of the EBBR unit. The indicated measurements that are calculated using soil temperature are also incorrect. See the work-around below. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2002 | 1900 | 11/13/2002 | 1929 |
12/11/2002 | 2000 | 12/11/2002 | 2029 |
Subject: | SGP/EBBR/E20 - Change of Energy Storage Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Because soil temperature measurements were not available from the beginning of the half hour, the change in soil energy storage could not be calculated and thus is incorrect. There is no fix to this problem. Average Soil Heat Flow, Sensible Heat Flux (h), and Latent Heat Flux (e) can not be calculated using the available, remaining measurements. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/23/2002 | 0215 | 10/30/2002 | 2000 |
Subject: | SGP/EBBR/E20 - Battery voltage low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When Battery Voltage drops below 10.5 volts, most measurements are suspect and some are often incorrect. The user will need to inspect the data carefully to determine the useability of the data. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/04/2002 | 1200 | 12/05/2002 | 1630 |
Subject: | SGP/EBBR/E20 - Wind speed and direction frozen |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE2.b1 |
Description: | Wind Speed and Dierction were frozen in place by an ice storm. |
Measurements: | sgp15ebbrE20.b1:
sgp5ebbrE2.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2002 | 1300 | 10/15/2002 | 1930 |
10/15/2002 | 2145 | 10/15/2002 | 1630 |
09/04/2002 | 1715 | 09/04/2002 | 1730 |
10/13/2002 | 1230 | 10/13/2002 | 1234 |
Subject: | SGP/EBBR/E22 - AEM Hung between home positions |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | When the AEM (Automatic Exchange Mechanism) is hung inbetween home positions, the gradients of temperature and relative humidity, and thus sensible and latent heat fluxes, are incorrect. There is no work-around to this problem. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/29/2002 | 0830 | 08/07/2002 | 1800 |
Subject: | SGP/EBBR/E22 - Water inside Broken Net Rad Dome |
DataStreams: | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The net radiation measurement is incorrect. Measurements calculated using net radiation are also incorrect. No work-around is possible for this situation. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/07/2002 | 1630 | 08/07/2002 | 1730 |
Subject: | SGP/EBBR/E20 - AEM Hung between Home Positions |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When the AEM (Automatic Exchange Mechanism) is hung inbetween home positions, the gradients of temperature and relative humidity, and thus sensible and latent heat fluxes, are incorrect. There is no work-around to this problem. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2002 | 2030 | 01/08/2003 | 1730 |
Subject: | SGP/EBBR/E20 - REPROCESS: Heat Flow #3 and #5 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Heat Flow #3 was incorrect because part of the lead wire was cut; apparent vandalism. Soil Heat Flow #5 had been incorrect because of other causes, but was replaced at the same time as #3. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/2002 | 1705 | 08/09/2002 | 1730 |
Subject: | SGP/EBBR/E20 - Data incorrect during instrument maintenance |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Most of the data was incorrect just after the EBBR unit was replaced. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/06/2002 | 2000 | 12/07/2002 | 0230 |
12/09/2002 | 0930 | 12/20/2002 | 1830 |
12/21/2002 | 1730 | 12/22/2002 | 0100 |
12/22/2002 | 0130 | 12/30/2002 | 2000 |
12/08/2002 | 0230 | 12/09/2002 | 0500 |
12/03/2002 | 1200 | 12/04/2002 | 0400 |
12/20/2002 | 2100 | 12/21/2002 | 1630 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Heat Flow #5 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Heat Flow #5 was incorrect during these periods. See below for a work-around. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/19/2002 | 1700 | 11/19/2002 | 2200 |
11/21/2002 | 2000 | 11/21/2002 | 2030 |
11/23/2002 | 1430 | 11/23/2002 | 2230 |
11/27/2002 | 2030 | 11/27/2002 | 2300 |
11/29/2002 | 1330 | 11/29/2002 | 2130 |
11/18/2002 | 1900 | 11/18/2002 | 2200 |
11/20/2002 | 1430 | 11/20/2002 | 2200 |
11/28/2002 | 1700 | 11/28/2002 | 2300 |
12/01/2002 | 1930 | 12/01/2002 | 2030 |
11/22/2002 | 1630 | 11/22/2002 | 2000 |
11/24/2002 | 1700 | 11/24/2002 | 2200 |
12/02/2002 | 1430 | 12/02/2002 | 2230 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #1 was intermittently incorrect. The cause is unknown. The indicated measurements that are calculated using soil temperature are also incorrect. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2002 | 2030 | 01/08/2003 | 1730 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #3 was incorrect. The cause is apparently vandalism; the probe leads were cut. The indicated measurements that are calculated using soil temperature are also incorrect. DQR D030117.19 already provides the work-around for calculating correct sensible (h) and latent heat (e) fluxes, as soil heat flow #3 and soil heat flow #5 were also incorrect during this period. That work-around is repeated below. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/20/2002 | 1300 | 10/20/2002 | 1500 |
Subject: | SGP/EBBR/E20 - Resistance-based Measurements Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When the Reference Temperature in the EBBR enclosure is not reported correctly, it affects all resistance-based measurements that are adjusted with the temperature of the reference junction. No work-around is possible for this situation. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/14/2002 | 1430 | 01/09/2003 | 1600 |
Subject: | SGP/EBBR/E19 - Soil Temperatures #2 and #3 Intermittently Bad |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Soil Temperatures #2 and #3 were intermittently incorrect. #3 appeared to be okay after the J-panel was replaced. #2 continues to be flaky, suggesting that the sensor itself has a problem. A DQPR has been submitted to replace #2. The indicated measurements that are calculated using soil temperature are also suspect. However, the intermittent problems normally occurred during night times and were fairly small in magnitude, thereby having little effect on the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/2003 | 1700 | 01/09/2003 | 1729 |
Subject: | SGP/EBBR/E19 - Measurements zero following logger restart |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. The restart on 01/09/03 occurred after J-panel replacements. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/2003 | 1730 | 01/09/2003 | 1759 |
Subject: | SGP/EBBR/E19 - Change of Energy Storage Incorrect |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Because soil temperature measurements were not available from the beginning of the half hour, the change in soil energy storage could not be calculated and thus is incorrect. There is no fix to this problem. Average Soil Heat Flow, Sensible Heat Flux (h), and Latent Heat Flux (e) can not be calculated using the available, remaining measurements. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/2002 | 1730 | 12/11/2002 | 1930 |
Subject: | SGP/EBBR/E20 - REPROCESS: Net Rad Coefficients Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The Net Radiometer coefficients were incorrect in the CR10 program when the replacement EBBR unit was installed on 08/09/02. The data can be easily corrected; see the Suggestion area below. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/20/2002 | 1830 | 12/20/2002 | 2100 |
12/22/2002 | 0100 | 12/22/2002 | 0130 |
12/21/2002 | 1630 | 12/21/2002 | 1730 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 and Soil Heat Flow #5 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #1 and Soil Heat Flow #5 were incorrect during these periods. The indicated calculated measurements are also incorrect. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2003 | 1000 | 02/01/2003 | 1000 |
Subject: | SGP/EBBR/E20 - RHtop Zero |
DataStreams: | sgp30ebbrE20.b1 |
Description: | The RHtop value in the 30 minute file is zero. 5 and 15 minute files show RHtop correctly. This behavior has been seen infrequently and can probably be attributed to a CR10 communication error. No other data, including the fluxes, are affected. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/2003 | 1630 | 01/09/2003 | 1700 |
Subject: | SGP/EBBR/E19 - Soil Temperature #2 Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | Soil Temperature #2 was incorrect during J-panel replacements. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/06/2003 | 1730 | 02/06/2003 | 1730 |
04/03/2003 | 1830 | 04/03/2003 | 1830 |
01/09/2003 | 1700 | 01/09/2003 | 1700 |
Subject: | SGP/EBBR/E19 - All Data Zeros |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | All data (5, 15, and 30 minute) was zero after replacement of sensors and restart of the CR10. This is a common occurrence. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/2003 | 1730 | 01/09/2003 | 1730 |
Subject: | SGP/EBBR/E19 - Several Soil Measurements Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | During replacement of a J-panel, several soil measurements were incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2003 | 1800 | 01/26/2003 | 1800 |
01/26/2003 | 1700 | 01/26/2003 | 1700 |
Subject: | SGP/EBBR/E19 -Several Soil Measurements Were Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | Several soil measurements were incorrect during replacement of soil temperature probe #2. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/02/2003 | 1730 | 03/03/2003 | 0030 |
02/28/2003 | 1330 | 03/02/2003 | 0530 |
Subject: | SGP/EBBR/E19 - AEM Hung in home30 position |
DataStreams: | sgp30ebbrE19.b1 |
Description: | The automatic exchange mechanism (AEM) hung in the home30 position, resulting in sensible and latent heat fluxes being incorrect. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/2003 | 1730 | 04/03/2003 | 1900 |
Subject: | SGP/EBBR/E19 - Soil Heat Flow #3 Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | Soil Heat Flow #3 was a flat -24 W/m2 for most of this period. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/03/2003 | 1900 | 04/03/2003 | 1900 |
Subject: | SGP/EBBR/E19 - Soil Heat Flow#1 Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Soil Heat Flow #1 was incorrect during replacement of some other sensors. |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/15/2003 | 1600 | 05/15/2003 | 1700 |
Subject: | SGP/EBBR/E19 - Many Measurements Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Many measurements were incorrect during replacement of a multiplexer. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2003 | 0000 | 06/25/2003 | 1700 |
Subject: | SGP/EBBR/E22 - home30 too large |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The home30 measurements sometimes exceeded 34.9999, resulting in the qc flag being set. However, this does not create any data quality issues. The qc flag is set just to provide an alert that the automatic exchange mechanism may have a problem; in this case data was not affected. An electronics repair solved the problem. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2003 | 0000 | 01/08/2003 | 1730 |
Subject: | SGP/EBBR/E20 - Soil Heat Flow#5 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Soil Heat Flow #5 was producing incorrect values. Average soil heat flow, sensible heat flux, and latent heat flux were affected. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/2003 | 2100 | 01/08/2003 | 2100 |
Subject: | SGP/EBBR/E20 - Soil Storage Incorrect After Startup |
DataStreams: | sgp30ebbrE20.b1 |
Description: | For the half hour data after CR10 datalogger startup, stored soil temperature values do not exist from the beginning of the half hour. Therefore soil heat storage can not be calculated correctly. This affects numerous measurements that are calculated using soil heat storage. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/08/2003 | 1545 | 05/08/2003 | 1615 |
Subject: | SGP/EBBR/E2 - 6 Month Checks |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2003 | 1440 | 05/01/2003 | 1515 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/16/2003 | 1950 | 04/16/2003 | 2045 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/30/2003 | 1720 | 04/30/2003 | 1800 |
Subject: | SGP/EBBR/E22 - 6 Month Checks |
DataStreams: | sgp30ebbrE22.b1, sgp5ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2003 | 0000 | 04/24/2003 | 1625 |
Subject: | SGP/EBBR/E2 - Soil Heat Flow #2 Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | Soil Heat Flow #2 producing incorrect values much of the time. Average soil heat flow, sensible heat flux, and latent heat flux were affected. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/24/2003 | 1630 | 04/24/2003 | 1630 |
Subject: | SGP/EBBR/E2 - Data All Zeros |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | All data (5, 15, and 30 minute) were zero after replacement of a sensor and restart of the CR10. This is a common occurrence. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/16/2003 | 2200 | 04/16/2003 | 2200 |
Subject: | SGP/EBBR/E2 - Bottom RH Incorrect |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The bottom RH was zero (and incorrect) for this period. |
Measurements: | sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/20/2003 | 0300 | 07/31/2003 | 1600 |
Subject: | SGP/EBBR/E2 - Soil Heat Flow #1 Incorrect |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Soil Heat Flow #1 was very large most of the period. See below for a work-around. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/10/2003 | 0030 | 07/10/2003 | 0030 |
Subject: | SGP/EBBR/E2 - Soil Heat Flow #3 Spike |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Soil heat flow #3 spiked to a value much greater than the other soil heat flows. However, this did not affect sensible and latent heat fluxes outside the error of the EBBR system. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/24/2003 | 1500 | 08/06/2003 | 1730 |
07/16/2003 | 0330 | 07/23/2003 | 1830 |
Subject: | SGP/EBBR/E22 - AEM Hung Inbetween Home Positions |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The AEM was hung inbetween home positions. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/16/2003 | 1745 | 09/17/2003 | 1900 |
Subject: | SGP/EBBR/E22 - AEM Home Signals Too High |
DataStreams: | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The AEM home signals were too large at times during the indicated period; it has been determined by the vendor that this is usually caused by electrical noise in the vicinity. When the 30 minute data shows a home 30 signal of 35 or more, the bowen ratio, and sensible and latent heat flux measurements are incorrect Removing the jumper between 4L and AG on the CR10 and adding a jumper to Multiplexer 2, Set 6, between L1 and L2 fixed the problem. The vendor intends to make this modification to all EBBR systems as they return for re-calibration. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/29/2003 | 0300 | 09/25/2003 | 1600 |
Subject: | SGP/EBBR/E2 - Water in Net Radiometer, Surface Fluxes Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | Water got inside the bird-pecked hole in the net radiometer during a rain. The net radiation and therefore latent and sensible heat fluxes are incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/30/2003 | 1400 | 09/04/2003 | 1445 |
Subject: | SGP/EBBR/E19 - Water in Net Radiometer; Surface Fluxes are Incorrect |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/31/2003 | 1630 | 07/31/2003 | 1630 |
Subject: | SGP/EBBR/E2 - 15 and 30 Minute Data are Zeros |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | 15 and 30 minute measurements were zero after restarting the CR10 datalogger. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/03/2003 | 1900 | 09/03/2003 | 1930 |
09/07/2003 | 1700 | 09/07/2003 | 1730 |
09/12/2003 | 1900 | 09/12/2003 | 2030 |
09/07/2003 | 1930 | 09/07/2003 | 1930 |
09/06/2003 | 1900 | 09/06/2003 | 1900 |
Subject: | SGP/EBBR/E2 - Soil Heat #1 Offscale |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Soil Heat Flow #1 was intermittently offscale. The reason is not clear. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/17/2003 | 2230 | 09/18/2003 | 0100 |
09/17/2003 | 1830 | 09/17/2003 | 2000 |
Subject: | SGP/EBBR/E19 - Tair Right Offscale |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The right air temperature data were going offscale. This affected the calculation of sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 2100 | 10/29/2003 | 2300 |
Subject: | SGP/EBBR/E20 - Fuse Blown in AEM |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When the EBBR system restarted on 15 Oct. 2003, the AEM malfunctioned. Surface fluxes data during this period are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/27/2003 | 1800 | 12/10/2003 | 2230 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature Probe #1 Measurements Spiked |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The soil temperature #1 measurement spiked quite high at times. This affected a number of measurements that are dependent on the soil temperature measurements. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/30/2003 | 0000 | 10/01/2003 | 2100 |
Subject: | SGP/EBBR/E20 - Water in Net Radiometer, Surface Fluxes Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2003 | 1800 | 10/01/2003 | 1630 |
Subject: | SGP/EBBR/E22 - Water in Net Radiometer, Surface Fluxes Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/03/2003 | 2000 | 11/13/2003 | 1615 |
Subject: | SGP/EBBR/E19 - Battery Voltage Too Low, Most Measurements Incorrect |
DataStreams: | sgp5ebbrE19.b1, sgp15ebbrE19.b1, sgp30ebbrE19.b1 |
Description: | Battery voltage dropped below levels required to sustain the production of valid data. The AC charger unit had failed. This prevented charging of the battery during the night and prevented the solar panel regulator from properly charging the battery during the day. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2003 | 2115 | 11/26/2003 | 1600 |
Subject: | SGP/EBBR/E19 - AEM Stuck In One Position, Surface Fluxes Incorrect |
DataStreams: | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The AEM home 15 and 30 outputs were both 40 mv because the AEM was not exchanging. Sensible and Latent Heat Fluxes are therefore incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2003 | 1505 | 10/10/2003 | 1755 |
Subject: | SGP/EBBR/E19 - Data Missing During Recalibration Changeout |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp30baebbrE19.c1, sgpebbrE19.00, sgpebbrE19.01 |
Description: | Data was missing during the recalibration changeout. |
Measurements: | sgpebbrE19.01:
sgpebbrE19.00:
sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
sgp30baebbrE19.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2003 | 1530 | 10/10/2003 | 1600 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/16/2003 | 1500 | 10/16/2003 | 1530 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/29/2003 | 2200 | 10/29/2003 | 2245 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp5ebbrE20.b1, sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/10/2003 | 1800 | 10/10/2003 | 1800 |
Subject: | SGP/EBBR/E19 - Data All Zeros |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The time period after restart of the datalogger produced all zero data. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 1900 | 10/15/2003 | 1930 |
Subject: | SGP/EBBR/E22 - 6 Month Checks |
DataStreams: | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/2003 | 1700 | 10/09/2003 | 1730 |
Subject: | SGP/EBBR/E2 - 6 Month Checks |
DataStreams: | sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/2003 | 0530 | 12/23/2003 | 2140 |
Subject: | SGP/EBBR/E20 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Wind direction is incorrect, reading at or about 0 or 15 to 25 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/28/2003 | 1430 | 01/21/2004 | 2130 |
Subject: | SGP/EBBR/E20 - Pressure Sensor Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The E20 pressure sensor suffered from spikes in pressure, which were related to increases in voltage during the day as the solar panels charged the battery. These spikes were not of a magnitude that would affect the 30 minute surface fluxes. Replacement of the pressure sensor solved the problem. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/2003 | 1800 | 10/09/2003 | 1800 |
Subject: | SGP/EBBR/E2 - All Data Zero After Logger Restart |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | All data was zero for the 5, 15, and 30 minute datastreams. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/14/2003 | 1500 | 12/14/2003 | 2200 |
Subject: | SGP/EBBR/E2 - Net Radiometer Iced Over During Storm |
DataStreams: | sgp30ebbrE2.b1, sgp15ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The net radiometer was covered with ice from a storm. Net radiation values are incorrect, and are sometimes even negative during the daytime. Sensible and latent heat fluxes are therefore incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/13/2003 | 1100 | 12/13/2003 | 1230 |
Subject: | SGP/EBBR/E20 - Wind Speed Sensor Frozen By Ice Storm |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The wind speed sensor was frozen stopped by ice from a storm. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2003 | 1810 | 12/13/2003 | 2100 |
Subject: | SGP/EBBR/E22 - Wind Speed Sensor Frozen By Ice Storm |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The wind speed sensor was frozen stopped by ice from a storm. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/13/2003 | 2345 | 12/14/2003 | 1520 |
Subject: | SGP/EBBR/E22 - Wind Direction Sensor Frozen By Ice Storm |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2003 | 1825 | 12/12/2003 | 2000 |
Subject: | SGP/EBBR/E19 - Wind Speed Sensor Frozen Stopped by Ice Storm |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. It is not known how long this condition existed, as data is missing for more than 10 days after the end of the stated period. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/2004 | 1600 | 01/22/2004 | 1530 |
Subject: | SGP/EBBR/E19 - Low Battery Voltage Caused Incorrect Data |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Battery voltage less than 10.5 V caused much data to be questionable or incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/13/2003 | 0000 | 03/17/2004 | 1835 |
Subject: | SGP/EBBR/E22 - Wind Speed Sensor Bearings Worn |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Wind speed was too low and/or often at or near zero due to worn bearings in the wind speed sensor. Sensor was replaced 3/17/04. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0505 | 02/02/2004 | 1845 |
Subject: | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0535 | 02/02/2004 | 1755 |
Subject: | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2004 | 1920 | 02/02/2004 | 1740 |
01/24/2004 | 2345 | 01/25/2004 | 0135 |
02/03/2004 | 0350 | 02/03/2004 | 1440 |
02/05/2004 | 0925 | 02/05/2004 | 1615 |
Subject: | SGP/EBBR/E22 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/05/2004 | 1120 | 02/05/2004 | 1500 |
Subject: | SGP/EBBR/E22 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2004 | 2120 | 02/02/2004 | 1910 |
Subject: | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2004 | 0105 | 02/03/2004 | 2100 |
01/25/2004 | 1345 | 01/28/2004 | 1640 |
Subject: | SGP/EBBR/E2 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/05/2004 | 1700 | 04/15/2004 | 1530 |
Subject: | SGP/EBBR/E19 - Reprocess: Incorrect Net Rad Calibration Coefficient |
DataStreams: | sgp30baebbrE19.c1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiometer coefficient installed on 2/5/04 for nighttime (negative voltage calibration) was incorrect. Negative net radiations during the subject period can be multiplied by 0.9419 to get corrected net radiation measurements. The sensible (H) and latent heat (LE) fluxes (which are very small at night anyway) can be recalculated using the following equations (where B is Bowen ratio, Rn is corrected net radiation, and G is soil heat flow): LE = -(Rn + G)/(B + 1) H = -(Rn + G + LE) |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
sgp30baebbrE19.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/11/2004 | 1830 | 06/01/2004 | 1800 |
Subject: | SGP/EBBR/E2 - Soil Heat Flow #1 Spikes Down |
DataStreams: | sgp30ebbrE2.b1 |
Description: | Soil heat flow #1 spiked down at times. Since tightening of connections this is occurring infrequently. In most cases, sensible and latent heat fluxes are not affected. |
Measurements: | sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2004 | 0000 | 03/31/2004 | 2355 |
Subject: | SGP/EBBR/E20 - Left Air Temperature Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30baebbrE20.c1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The left air temperature, and therefore top and bottom air temperatures were offscale or incorrect on occasion. Bowen ratio, sensible heat flux, and latent heat flux were also incorrect during those times. Inspection of the data is required to detect the incorrect periods. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30baebbrE20.c1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/1997 | 0000 | 05/06/2003 | 2359 |
Subject: | SGP/EBBR/E19 - Metadata errors |
DataStreams: | sgp15ebbrE19.b1, sgp30baebbrE19.c1, sgp30ebbrE19.b1 |
Description: | The latitude, longitude and altitude of the El Reno (E19) site were incorrectly entered into the ARM database. The correct location of the EBBR.E19 instrument is: Lat: 35.557N Lon: 98.017W Alt: 421m |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
sgp30baebbrE19.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 05/06/2003 | 2359 |
Subject: | SGP/EBBR/E19 - Metadata errors |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The latitude, longitude and altitude of the El Reno (E19) site were incorrectly entered into the ARM database. The correct location of the EBBR.E19 instrument is: Lat: 35.557N Lon: 98.017W Alt: 421m |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/29/2004 | 2215 | 06/10/2004 | 1510 |
Subject: | SGP/EBBR/E19 - AEM Hung Inbetween Home Positions |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The AEM hung inbetween home positions, producing a home signal of zero. Sensible and latent heat fluxes during this period are incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/22/2004 | 0400 | 06/23/2004 | 1650 |
Subject: | SGP/EBBR/E22 - Net Radiation Incorrect |
DataStreams: | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Rain filled the bottom of the net radiometer with water, resulting in very high net radiations. Net radiation is incorrect during this period, also causing sensible and latent heat fluxes to be incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/09/2004 | 1745 | 08/04/2004 | 1915 |
Subject: | SGP/EBBR/E20 - Wind Direction Stuck at 100 Degrees |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was stuck at about 100 degrees. This did not affect the primary measurements (net radiation, soil heat flow, sensible heat flux, latent heat flux). |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2004 | 1330 | 07/07/2004 | 1900 |
Subject: | SGP/EBBR/E22 - Water In Net Radiometer |
DataStreams: | sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Water entered the Net Radiometer through a cracked upper dome, causing the net radiation values to be too large. As a result, latent and sensible heat flux values are also incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/03/2004 | 0300 | 09/15/2004 | 2000 |
09/24/2004 | 0700 | 09/29/2004 | 1800 |
Subject: | SGP/EBBR/E20 - AEM Failure |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The AEM hung inbetween positions; home signals were zero. The AEM fuse kept blowing, most likely because of worn rails or sleeves. This condition may reoccur. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/31/2004 | 1300 | 09/09/2004 | 1500 |
Subject: | SGP/EBBR/E2 - Net Radiometer Dome Broken, Reducing Net Radiation Measurement, Fluxes |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The upper dome of the net radiometer was broken. Normally this alone does not affect the net radiation measurement. However, in this case the breakage must have been more than just a bird claw hole or a crack, resulting in obstruction of the top sensing surface of the net radiometer and greatly reduced net radiation measurements. Sensible and latent heat fluxes were reduced as a result. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/08/2004 | 2130 | 09/15/2004 | 1930 |
Subject: | SGP/EBBR/E20 - Soil Heat Flow #3 and Soil Temperature #3 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/15/2004 | 1930 | 09/15/2004 | 2030 |
Subject: | SGP/EBBR/E20 - All Soil Measurements Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | All soil measurements were incorrect during the replacement of soil heat flow #3 and soil temperature #3. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/02/2004 | 0630 | 10/21/2004 | 1500 |
Subject: | SGP/EBBR/E2 - Soil Heat Flow Sensor #2 Bad |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | Soil Heat Flow sensor #2 spiked downwards at times for a while, but eventually became negative continuously. The problem was fixed when the sensor was replaced. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/28/2004 | 1430 | 10/28/2004 | 1500 |
Subject: | SGP/EBBR/E19 - 6 Month Checks |
DataStreams: | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2004 | 1730 | 09/29/2004 | 1800 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/27/2004 | 1700 | 10/27/2004 | 1730 |
Subject: | SGP/EBBR/E22 - 6 Month Checks |
DataStreams: | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/02/2004 | 1330 | 03/02/2005 | 1930 |
Subject: | SGP/EBBR/E20 - Soil Moisture #4 and Soil Temperature #4 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Failures of a multiplexer channel and a J-panel channel caused soil temperature #4 and soil moisture #4 to spike and drift at times. Replacement of the failed equipment solved the problem. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/21/2004 | 1500 | 10/21/2004 | 1530 |
Subject: | SGP/EBBR/E2 - 6 Month Checks |
DataStreams: | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/26/2004 | 2100 | 12/08/2004 | 2100 |
Subject: | SGP/EBBR/E20 - Soil Heat Flow #4 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Soil Heat Flow #4 was missing or offscale and therefore incorrect during the stated period. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 0655 | 01/07/2005 | 1545 |
Subject: | SGP/EBBR/E19 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1420 | 01/07/2005 | 1650 |
Subject: | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 0845 | 01/07/2005 | 1555 |
Subject: | SGP/EBBR/E22 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/03/2005 | 0530 | 01/09/2005 | 0830 |
Subject: | SGP/EBBR/E2 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/03/2005 | 0915 | 01/08/2005 | 2140 |
Subject: | SGP/EBBR/E2 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/2005 | 0150 | 01/07/2005 | 1425 |
Subject: | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 0855 | 01/06/2005 | 1940 |
Subject: | SGP/EBBR/E22 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1115 | 01/06/2005 | 2055 |
Subject: | SGP/EBBR/E19 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/29/2005 | 0930 | 01/29/2005 | 1300 |
Subject: | SGP/EBBR/E19 - Wind Speed Constant |
DataStreams: | sgp30ebbrE19.b1, sgp15ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Wind Speed was constant at 5 m/s during this period; the reason is unknown. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/11/2005 | 0915 | 01/11/2005 | 2100 |
Subject: | SGP/EBBR/E22 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/11/2005 | 1730 | 01/11/2005 | 1825 |
Subject: | SGP/EBBR/E22 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/11/2005 | 1640 | 01/13/2005 | 1630 |
02/07/2005 | 0600 | 02/09/2005 | 1930 |
Subject: | SGP/EBBR/E2 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/08/2005 | 2330 | 02/09/2005 | 1600 |
Subject: | SGP/EBBR/E2 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/06/2005 | 1400 | 03/16/2005 | 1900 |
Subject: | SGP/EBBR/E22 - Net Radiation Too Low - Top Dome Broken |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Net radiation values were too low because of a broken top dome. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/05/2004 | 1700 | 03/05/2005 | 1730 |
Subject: | SGP/EBBR/E19 - Reprocess: Negative Net Rad calibrations |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The calibration for negative net radiation was incorrectly entered in the datalogger program. |
Measurements: | sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/30/2005 | 2000 | 04/13/2005 | 1700 |
Subject: | SGP/EBBR/E20 - Wrong Datalogger Program Installed |
DataStreams: | sgp30ebbrE20.b1 |
Description: | ts4 went offscale and sm4 dropped to a constant 16% when a "new" program was installed on 3/30/05. The wrong program was installed. Because ts4 did not change with time, it did not mess up the calculation of e and h. e and h are slightly overestimated, but only by about 1%, far less than the system error. This is a rare type of instrument problem where the concequences are minimal. Therefore, e and h are not listed as incorrect in this DQR and are still usable during the stated period. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/20/2005 | 1230 | 04/27/2005 | 2000 |
Subject: | SGP/EBBR/E20 - Temp. of thum_left Incorrect At Times |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The temperature portion of the left T/RH probe temperature spiked at times. This was caused by a faulty surge protector in the J-Panel. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2005 | 2300 | 05/12/2005 | 1445 |
Subject: | SGP/EBBR/E19 - Net Radiation Incorrect - Cable Chewed by Rodents |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiation measurement was incorrect after the net radiometer cable was chewed by rodents. Sensible and latent heat fluxes were therefore incorrect. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/31/2005 | 1600 |
Subject: | SGP/EBBR/E19 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Effective 20050331.1600, the EBBR.E19 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050331, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE19.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE19.a1). |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/30/2005 | 1900 |
Subject: | SGP/EBBR/E20 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Effective 20050330.1900, the EBBR.E20 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050330, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE20.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE20.a1). |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/30/2005 | 1930 |
Subject: | SGP/EBBR/E22 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE22.b1 |
Description: | Effective 20050330.1930, the EBBR.E20 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050330, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE20.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE20.a1). |
Measurements: | sgp30ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/24/2005 | 1700 |
Subject: | SGP/EBBR/E2 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE2.b1 |
Description: | Effective 20050324.1700, the EBBR.E2 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050324, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE2.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE2.a1). |
Measurements: | sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/05/2005 | 1730 | 07/06/2005 | 1930 |
08/23/2005 | 1900 | 08/31/2005 | 1700 |
09/01/2005 | 1730 | 09/02/2005 | 0300 |
09/02/2005 | 1100 | 09/15/2005 | 2230 |
09/16/2005 | 0100 | 09/28/2005 | 1830 |
Subject: | SGP/EBBR/E20 - Soil Temperature and Soil Moisture #4 Measurements Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The ts4 sensor reported 99999 values because the sensor leads were loose. Soil moisture #4 reported low values (steady 16%) during this time period. The sensible and latent heat fluxes were not affected by this problem, only soil temperature and soil moisture #4. See soil temperatures and soil moistures from sets #2, #3, and #5 for correct values (note: soil temperature #1 was having problems during the same time). |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/04/2005 | 2200 | 08/11/2005 | 1530 |
Subject: | SGP/EBBR/E2 - Net Radiation Incorrect; Latent and Sensible Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The top dome of the net radiometer was broken and water entered, causing incorrect net radiation measurements. This resulted in incorrect sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/27/2005 | 2000 | 08/31/2005 | 1730 |
Subject: | SGP/EBBR/E22 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The net radiometer top dome was broken and water got inside, making the net radiation, and sensible and latent heat flux measurements incorrect. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/10/2005 | 1600 | 03/24/2005 | 1700 |
Subject: | SGP/EBBR/E2 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE2.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/03/2005 | 1730 | 03/31/2005 | 1600 |
Subject: | SGP/EBBR/E19 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE19.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/02/2005 | 1900 | 03/30/2005 | 1900 |
Subject: | SGP/EBBR/E20 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/16/2005 | 1830 | 03/30/2005 | 1930 |
Subject: | SGP/EBBR/E22 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE22.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E19 - metadata corrections |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E19 data collected by ARM back to the beginning of the data set in May 1997. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil type 4) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E2 - metadata corrections |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E2 data collected by ARM back to the installation of the instrument in May 1997. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E20 - metadata corrections |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E20 data collected by ARM back to the installation of the instrument in April 1993. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E22 - metadata corrections |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E22 data collected by ARM back to the installation of the instrument in April 1993. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil type 4) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/24/2005 | 0600 | 10/25/2005 | 0100 |
10/31/2005 | 1030 | 12/20/2005 | 1940 |
Subject: | SGP/EBBR/E19 - Net Radiation, Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | The net radiometer cable was chewed by an animal. Net Radiation, Sensible Heat Flux, and Latent Heat Flux were incorrect during the stated periods. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2005 | 0000 | 01/19/2006 | 1630 |
Subject: | SGP/EBBR/E19 - Incorrect Sensible and Latent Heat Fluxes |
DataStreams: | sgp5ebbrE19.b1, sgp30ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | The gradient measurements and latent and sensible heat fluxes were incorrect because the AEM was not exchanging. The problem was fixed by replacing the AEM. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/09/2005 | 0700 | 12/09/2005 | 0700 |
12/08/2005 | 0700 | 12/08/2005 | 0700 |
12/17/2005 | 2130 | 12/21/2005 | 1930 |
12/08/2005 | 1130 | 12/08/2005 | 1430 |
Subject: | SGP/EBBR/E2 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp5ebbrE2.b1, sgp30ebbrE2.b1, sgp15ebbrE2.b1 |
Description: | The sensible and latent heat fluxes and the gradient measurements were incorrect during this period because the AEM did not switch positions properly. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/2005 | 0930 | 12/21/2005 | 1730 |
Subject: | SGP/EBBR/E20 - Data Incorrect During J-Panel Replacement |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Much of the data was incorrect during replacement of J-Panel #1. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/10/2006 | 0730 | 01/18/2006 | 2000 |
Subject: | SGP/EBBR/E22 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp5ebbrE22.b1, sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/12/2006 | 1900 | 05/24/2006 | 1700 |
Subject: | SGP/EBBR/E22 - Fluxes Incorrect When Soil Heat Flow #3 Out of Range |
DataStreams: | sgp30ebbrE22.b1 |
Description: | When soil heat flow #3 exceeded the range limit in the EBBR program, it was replaced with 9999es. This caused the ave_shf and the sensible and latent heat fluxes to be incorrect. |
Measurements: | sgp30ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/21/2006 | 0400 | 01/21/2006 | 1530 |
Subject: | SGP/EBBR/E2 - Wind Speed Sensor Frozen Stopped |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | Freezing rain froze the wind speed sensor to a stopped condition. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/22/2006 | 0300 | 02/25/2006 | 1630 |
Subject: | SGP/EBBR/E20 - Suspect Measurements |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Some measurements may be incorrect because of low supply voltage. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/21/2006 | 1130 | 01/21/2006 | 1700 |
01/22/2006 | 0100 | 01/22/2006 | 0730 |
Subject: | SGP/EBBR/E22 - Wind Speed Sensor Frozen Stopped |
DataStreams: | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | The wind speed sensor was frozen to a stopped condition. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/17/2006 | 0900 | 06/20/2006 | 1915 |
Subject: | SGP/EBBR/E20 - Net Radiation, Fluxes Too Large |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Net Radiation was way too large because of water in the bottom dome. This resulted in the sensible and latent heat fluxes being too large also. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/21/2006 | 0630 | 08/30/2006 | 1800 |
Subject: | SGP/EBBR/E22 - Net Radiation and Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Rain entered the net radiometer, causing net radiation, and thus sensible and latent heat fluxes, to be too large. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/16/2006 | 0000 | 11/08/2006 | 1940 |
Subject: | SGP/EBBR/E22 - Soil Heat Flow #4 Incorrect - Sensible and Latent Heat Fluxes Sometimes |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | Soil heat flow sensor #4 dropped to low values or offscale. Sensible and latent heat fluxes were sometimes affected. |
Measurements: | sgp30ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/2006 | 1500 | 10/12/2006 | 1630 |
Subject: | SGP/EBBR/E19 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE19.b1 |
Description: | The sensible and latent heat fluxes were incorrect when the top and bottom air temperatures were incorrect. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/22/1997 | 2100 | 10/12/2003 | 2330 |
Subject: | SGP/EBBR/E2 - Wind Direction Dependency of Surface Fluxes and General Data Quality |
DataStreams: | sgp30ebbrE2.b1 |
Description: | Beginning in FY2006, Data Quality Reports are not written for missing data or for situations when qc flags clearly show that the data is incorrect (this is true for most of the conditions listed below). DQRs are written for periods when data is incorrect, when the situation is not represented by qc flags in the data, and it's not obvious that the data should have been flagged as incorrect. The EBBR data is only useful for particular wind directions at each Extended Facility. Please use the following resources to help in interpreting the EBBR data. 1) qc flags in the EBBR data. 2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/ 3) SGP EF Surface Conditions Observations (EFSCO) at http://198.124.96.210:591/sfc_cond1/default.htm 4) Surface fluxes are valid only for the following wind directions (in degrees): 71-137, 223-289 Note that there are wind directions at most sites for which the fetch is insufficient and therefore EBBR data is invalid. Appropriate fetch was determined from a 1/40 measurement height to fetch ratio, resulting in a required minimum fetch of 120 m. Particular attention should be paid to the limited valid wind directions for the Central Facility EBBR. The surface vegetation type for the EBBRs is grazed or ungrazed grassland (refer to the EFSCO for state). 5) Some conditions that commonly cause the EBBR primary measurements to be incorrect or missing follow: a) Sensible and latent heat fluxes are not accurate during times when the Automatic Exchange Mechanism (AEM) is not functioning properly. The AEM switches the gradient measuring instrumentation between the top and bottom positions every 15 minutes; this reduces the effects of instrument offsets. Sometimes the AEM does not reach it's full extent of travel, resulting in the home signal being zero. b) Sensible and latent heat fluxes are sometimes incorrect when surface soil heat flow is out of range, as seen in the average soil heat flux (ave_shf). c) Very light winds may be seen at nights for brief periods. Wind direction flops around a lot during low wind conditions (< 1.5 m/s) and is often unreliable during those periods. d) Missing data periods occur at times; this is usually a site data system collection/communication problem; it can also occur during replacement of the system with a newly calibrated unit. Missing data is sometimes filled in later from manual or automatic re-collection of the data. |
Measurements: | sgp30ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/1997 | 1000 | 10/12/2003 | 2330 |
Subject: | SGP/EBBR/E19 - Wind Direction Dependency of Surface Fluxes and General Data Quality |
DataStreams: | sgp30ebbrE19.b1 |
Description: | Beginning in FY2006, Data Quality Reports are not written for missing data or for situations when qc flags clearly show that the data is incorrect (this is true for most of the conditions listed below). DQRs are written for periods when data is incorrect, when the situation is not represented by qc flags in the data, and it's not obvious that the data should have been flagged as incorrect. The EBBR data is only useful for particular wind directions at each Extended Facility. Please use the following resources to help in interpreting the EBBR data. 1) qc flags in the EBBR data. 2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/ 3) SGP EF Surface Conditions Observations (EFSCO) at http://198.124.96.210:591/sfc_cond1/default.htm 4) Surface fluxes are valid only for the following wind directions (in degrees): 0-133, 151-360 Note that there are wind directions at most sites for which the fetch is insufficient and therefore EBBR data is invalid. Appropriate fetch was determined from a 1/40 measurement height to fetch ratio, resulting in a required minimum fetch of 120 m. Particular attention should be paid to the limited valid wind directions for the Central Facility EBBR. The surface vegetation type for the EBBRs is grazed or ungrazed grassland (refer to the EFSCO for state). 5) Some conditions that commonly cause the EBBR primary measurements to be incorrect or missing follow: a) Sensible and latent heat fluxes are not accurate during times when the Automatic Exchange Mechanism (AEM) is not functioning properly. The AEM switches the gradient measuring instrumentation between the top and bottom positions every 15 minutes; this reduces the effects of instrument offsets. Sometimes the AEM does not reach it's full extent of travel, resulting in the home signal being zero. b) Sensible and latent heat fluxes are sometimes incorrect when surface soil heat flow is out of range, as seen in the average soil heat flux (ave_shf). c) Very light winds may be seen at nights for brief periods. Wind direction flops around a lot during low wind conditions (< 1.5 m/s) and is often unreliable during those periods. d) Missing data periods occur at times; this is usually a site data system collection/communication problem; it can also occur during replacement of the system with a newly calibrated unit. Missing data is sometimes filled in later from manual or automatic re-collection of the data. |
Measurements: | sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/06/1993 | 0630 | 10/04/2003 | 2330 |
Subject: | SGP/EBBR/E20 - Wind Direction Dependency of Surface Fluxes and General Data Quality |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Beginning in FY2006, Data Quality Reports are not written for missing data or for situations when qc flags clearly show that the data is incorrect (this is true for most of the conditions listed below). DQRs are written for periods when data is incorrect, when the situation is not represented by qc flags in the data, and it's not obvious that the data should have been flagged as incorrect. The EBBR data is only useful for particular wind directions at each Extended Facility. Please use the following resources to help in interpreting the EBBR data. 1) qc flags in the EBBR data. 2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/ 3) SGP EF Surface Conditions Observations (EFSCO) at http://198.124.96.210:591/sfc_cond1/default.htm 4) Surface fluxes are valid only for the following wind directions (in degrees): 0-230, 310-360 Note that there are wind directions at most sites for which the fetch is insufficient and therefore EBBR data is invalid. Appropriate fetch was determined from a 1/40 measurement height to fetch ratio, resulting in a required minimum fetch of 120 m. Particular attention should be paid to the limited valid wind directions for the Central Facility EBBR. The surface vegetation type for the EBBRs is grazed or ungrazed grassland (refer to the EFSCO for state). 5) Some conditions that commonly cause the EBBR primary measurements to be incorrect or missing follow: a) Sensible and latent heat fluxes are not accurate during times when the Automatic Exchange Mechanism (AEM) is not functioning properly. The AEM switches the gradient measuring instrumentation between the top and bottom positions every 15 minutes; this reduces the effects of instrument offsets. Sometimes the AEM does not reach it's full extent of travel, resulting in the home signal being zero. b) Sensible and latent heat fluxes are sometimes incorrect when surface soil heat flow is out of range, as seen in the average soil heat flux (ave_shf). c) Very light winds may be seen at nights for brief periods. Wind direction flops around a lot during low wind conditions (< 1.5 m/s) and is often unreliable during those periods. d) Missing data periods occur at times; this is usually a site data system collection/communication problem; it can also occur during replacement of the system with a newly calibrated unit. Missing data is sometimes filled in later from manual or automatic re-collection of the data. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/04/1993 | 1200 | 10/12/2003 | 2330 |
Subject: | SGP/EBBR/E22 - Wind Direction Dependency of Surface Fluxes and General Data Quality |
DataStreams: | sgp30ebbrE22.b1 |
Description: | Beginning in FY2006, Data Quality Reports are not written for missing data or for situations when qc flags clearly show that the data is incorrect (this is true for most of the conditions listed below). DQRs are written for periods when data is incorrect, when the situation is not represented by qc flags in the data, and it's not obvious that the data should have been flagged as incorrect. The EBBR data is only useful for particular wind directions at each Extended Facility. Please use the following resources to help in interpreting the EBBR data. 1) qc flags in the EBBR data. 2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/ 3) SGP EF Surface Conditions Observations (EFSCO) at http://198.124.96.210:591/sfc_cond1/default.htm 4) Surface fluxes are valid only for the following wind directions (in degrees): 0-49, 139-360 Note that there are wind directions at most sites for which the fetch is insufficient and therefore EBBR data is invalid. Appropriate fetch was determined from a 1/40 measurement height to fetch ratio, resulting in a required minimum fetch of 120 m. Particular attention should be paid to the limited valid wind directions for the Central Facility EBBR. The surface vegetation type for the EBBRs is grazed or ungrazed grassland (refer to the EFSCO for state). 5) Some conditions that commonly cause the EBBR primary measurements to be incorrect or missing follow: a) Sensible and latent heat fluxes are not accurate during times when the Automatic Exchange Mechanism (AEM) is not functioning properly. The AEM switches the gradient measuring instrumentation between the top and bottom positions every 15 minutes; this reduces the effects of instrument offsets. Sometimes the AEM does not reach it's full extent of travel, resulting in the home signal being zero. b) Sensible and latent heat fluxes are sometimes incorrect when surface soil heat flow is out of range, as seen in the average soil heat flux (ave_shf). c) Very light winds may be seen at nights for brief periods. Wind direction flops around a lot during low wind conditions (< 1.5 m/s) and is often unreliable during those periods. d) Missing data periods occur at times; this is usually a site data system collection/communication problem; it can also occur during replacement of the system with a newly calibrated unit. Missing data is sometimes filled in later from manual or automatic re-collection of the data. |
Measurements: | sgp30ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/16/2002 | 0405 | 02/18/2002 | 2100 |
02/08/2002 | 2005 | 02/11/2002 | 1300 |
02/23/2002 | 0305 | 02/28/2002 | 1300 |
01/30/2002 | 1805 | 02/06/2002 | 1225 |
03/09/2002 | 2105 | 03/11/2002 | 2005 |
12/07/2001 | 1505 | 12/11/2001 | 1630 |
Subject: | SGP/EBBR/E2 - Missing data |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1, sgp30baebbrE2.c1 |
Description: | Data are missing and unrecoverable. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp30baebbrE2.c1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/23/2007 | 1530 | 01/25/2007 | 1725 |
02/03/2004 | 2105 | 02/12/2004 | 1555 |
Subject: | SGP/EBBR/E2 - Missing data |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
Description: | Data are missing and unrecoverable |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/03/2007 | 1000 | 02/22/2007 | 1645 |
Subject: | SGP/EBBR/E2 - Windspeed sensor failure |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The windspeed sensor developed an abnormally high wind speed threshold due to worn bearings. Wind speeds were often measured to be too low. Inspect the data to identify suspect time periods. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/16/2007 | 0400 | 04/26/2007 | 1630 |
Subject: | SGP/EBBR/E22 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | Wind direction was flat-lining at 135 degrees and occasionally changed to 0.4 degrees. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/10/2007 | 1500 | 09/12/2007 | 2045 |
Subject: | SGP/EBBR/E20 - Reprocess: Wind Direction 20 Degrees Low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The EBBR wind direction was found to be misaligned 20 degrees low. This bias should have had no effect on the res_ws or sigma_wd measurements. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/20/2007 | 0630 | 08/01/2007 | 2200 |
Subject: | SGP/EBBR/E22 - H and LE Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | Soil Heat Flow 1 bounced around and went offscale at times, resulting in the EBBR program setting sensible and latent heat fluxes to 9999es. The problem ended during a PM visit, possibly because of routine checks and tightening of leads in terminal strips. |
Measurements: | sgp30ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2007 | 0000 | 10/24/2007 | 1900 |
Subject: | SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor reported wind directions that were 65 degrees too low because of a mis-alignment. This bias should have no effect on the res_ws or sigma_wd measurements. The wind direction data could be re-processed by adding 65 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/08/2008 | 0600 | 05/07/2008 | 2000 |
Subject: | SGP/EBBR/E20 - Wind Direction 50 Degrees High |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction was offset high about 50 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/02/2008 | 1630 | 05/15/2008 | 2000 |
Subject: | SGP/EBBR/E2 - Net Radiation and Fluxes Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The net radiometer was tipped 37 degrees eastward, resulting in apparent solar noon being 2.5 hours early. The net radiation error results in incorrect sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2008 | 0600 | 05/07/2008 | 0900 |
05/07/2008 | 1530 | 05/07/2008 | 2130 |
05/09/2008 | 1330 | 05/09/2008 | 1330 |
Subject: | SGP/EBBR/E19 - Sensible and latent heat flux and net radiation incorrect |
DataStreams: | sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1 |
Description: | Net radiation was too large, resulting in sensible and latent heat fluxes being too large. The cause of the problem is unknown. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/07/2008 | 0030 | 06/12/2008 | 1730 |
Subject: | SGP/EBBR/E2 - AEM Ventilator Dangling - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | The right AEM ventilator unit with temperature and humidity sensors inside was dangling from the AEM. Therefore, the gradients of temperature and relative humidity and thus sensible and latent heat flux are suspect for this period. Often, the fluxes look reasonable. |
Measurements: | sgp30ebbrE2.b1:
sgp15ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/15/2008 | 0230 | 09/10/2008 | 2230 |
Subject: | SGP/EBBR/E20 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction differed from the co-located SMOS by 50 deg during part of the stated period and the electronics had failed completely resulting in a constant 135 degrees for the following dates and times: 08/15 0230-0430, 0830-1530 and 09/03 0200-0300, 0500 - 09/10 2230. Sensible and latent heat fluxes were not affected by this problem. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2009 | 1910 | 01/27/2009 | 0800 |
Subject: | SGP/EBBR/E20 - Wind Speed Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind speed sensor was frozen stopped by freezing rain. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2009 | 1835 | 01/28/2009 | 1825 |
Subject: | SGP/EBBR/E19 - Wind Speed Incorrect |
DataStreams: | sgp30ebbrE19.b1, sgp5ebbrE19.b1, sgp15ebbrE19.b1 |
Description: | Wind Speed was frozen stopped by ice and was incorrect during this period. |
Measurements: | sgp15ebbrE19.b1:
sgp5ebbrE19.b1:
sgp30ebbrE19.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2009 | 1845 | 01/28/2009 | 1810 |
Subject: | SGP/EBBR/E22 - Wind Speed Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1 |
Description: | The wind speed sensor was frozen stopped by freezing rain. |
Measurements: | sgp30ebbrE22.b1:
sgp5ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/12/2009 | 0305 | 04/22/2009 | 1400 |
Subject: | SGP/EBBR/E20 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction measurement was stuck at 40 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2009 | 0000 | 10/20/2009 | 1330 |
Subject: | SGP/EBBR/E2 - Low Supply Voltage |
DataStreams: | sgp15ebbrE2.b1, sgp30ebbrE2.b1, sgp5ebbrE2.b1 |
Description: | Low supply voltage caused incorrect and missing data during much of the period. This facility was decommissioned 10/20/2009 and maintenance was discontinued effective 10/01/2009. |
Measurements: | sgp15ebbrE2.b1:
sgp30ebbrE2.b1:
sgp5ebbrE2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/1997 | 0000 | 04/21/2000 | 1640 |
Subject: | SGP/EBBR/E22 - Reprocess: E22 Soil Moisture Values Off End of Calibration at High Soil |
DataStreams: | sgp30ebbrE22.b1, sgp15ebbrE22.b1 |
Description: | Intermittently, since November 1997 soil moisture probes 1, 2, and 3 indicate small positive or else negative values when soil moisture is high (greater than 35%). This situation is similar to that at the Cement EBBR, although the soil at Cordell is not capable of holding as much water as that at Cement. The cause of the problem is inadequate range in the calibration curve equation. Very high soil moisture cannot be obtained with the calibration soil used by REBS. The soil moisture equations could be manipulated to allow larger soil moistures to be calculated. However, the infrequency of occurence does not justify doing so. The soil moisture data must be inspected by the data user to see when soil moisture values for one or more probes is inconsistent with the others. Recalculation of ave_shf, e, and h must be made using only the soil moisture sets with correct soil moisture values. Affected data values are (# for probe number): 15 minute: rr_sm# 30 minute: sm#, c_shf#, cs#, ces#, g#, ave_shf, e, h Sensible, latent, and soil heat fluxes can be recalculated using the soil probe sets that provide correct data. For example, if soil moisture 2 is incorrect, ave_shf = (g1 + g3 + g4 + g5)/4 e = -(q + ave_shf)/(1 +bowen) h = -(e + ave_shf +q), If soil moistures 1 and 2 are incorrect, ave_shf = (g3 + g4 + g5)/3 e = -(q + ave_shf)/(1 +bowen) h = -(e + ave_shf +q), If soil moistures 1, 2, and 3 are incorrect, ave_shf = (g4 + g5)/2 e = -(q + ave_shf)/(1 +bowen) h = -(e + ave_shf +q), etc. |
Measurements: | sgp30ebbrE22.b1:
sgp15ebbrE22.b1:
|