Data Quality Reports for Session: 142786 User: wlj Completed: 06/01/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D021211.1TWP/SMET/C3 - Lower wind direction sensor misaligned twpsmet60sC3.a1, twpsmet60sC3.b1
D030212.1TWP/SMET/C3 - Intermittent Pressure Sensor Failuretwpsmet60sC3.a1, twpsmet60sC3.b1
D031103.2TWP/SMET/C3 - Data reported at 15sec rather than 60s intervalstwpsmet60sC3.a1, twpsmet60sC3.b1
D040722.4TWP/SMET/C3 - Rain blocked pressure porttwpsmet60sC3.b1
D040726.3TWP/SMET/C3 - Negative rainfall ratestwpsmet60sC3.b1
D040726.4TWP/SMET/C3 - Negative rainfall ratestwpsmet60sC3.a1
D050210.1TWP/SMET/C3 - Data non-representativetwpsmet60sC3.b1
D050322.2TWP/SMET/C2 - Upper wind direction sensor failuretwpsmet60sC2.b1
D050418.2TWP/SMET/C3 - Lower wind direction sensor failuretwpsmet60sC3.b1
D050714.1TWP/SMET/C2 - RH sensor failuretwpsmet60sC2.b1
D050808.3TWP/SMET/C3 - Data not representativetwpsmet60sC3.b1
D050920.4TWP/SMET/C2 - Instrument maintenancetwpsmet60sC2.b1
D050921.2TWP/SMET/C2 - ORG data incorrecttwpsmet60sC2.b1
D051005.6TWP/SMET/C2 - Tower down for calibration activitiestwpsmet60sC2.b1
D051115.1TWP/SMET/C3 - Upper wind sensor failuretwpsmet60sC3.b1
D051117.2TWP/SMET/C3 - RH Values Artificially Hightwpsmet60sC3.b1
D051117.3TWP/SMET/C3 - Instrument failuretwpsmet60sC3.b1
D060426.8TWP/SMET/C3 - ORG data noisy due to degraded groundtwpsmet60sC3.b1
D060502.3TWP/SMET/C3 - Reprocessed: Lower windspeed sensor calibration errortwpsmet60sC3.b1
D060614.2TWP/SMET/C2 - Temp/RH probe failuretwpsmet60sC2.b1
D060627.1TWP/SMET/C3 - Data not representativetwpsmet60sC3.b1
D060818.3TWP/SMET/C3 - Reprocess: Barometric pressure units change twpsmet60sC3.b1
D061011.3TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC2.b1
D061011.4TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC3.b1
D061214.2TWP/SMET/C2 - Barometer failuretwpsmet60sC2.b1
D070306.2TWP/SMET/C3 - Barometer Data Incorrecttwpsmet60sC3.b1
D070306.3TWP/SMET/C3 - Water in enclosuretwpsmet60sC3.b1
D070510.5TWP/SMET/C2 - Lower windspeed sensor questionabletwpsmet60sC2.b1
D070520.1TWP/SMET/C2 - Lower Wind Sensor Direction Incorrecttwpsmet60sC2.b1
D070803.1TWP/SMET/C3 - Upper wind speed artificially slowtwpsmet60sC3.b1
D071105.1TWP/SMET/C3 - ORG overestimated rainfalltwpsmet60sC3.b1
D071219.1TWP/SMET/C2 - Lower Wind Speed Data Suspecttwpsmet60sC2.b1
D080225.1TWP/SMET/C3 - Upper Wind Sensor Data Questionabletwpsmet60sC3.b1
D080428.3TWP/SMET/C3 - Reprocess: ORG Data has very small rainrate valuestwpsmet60sC3.b1
D080428.4TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate valuestwpsmet60sC2.b1
D080611.2TWP/SMET/C3 - Lower Wind Direction Intermittently Wrongtwpsmet60sC3.b1
D080617.1TWP/SMET/C2 - ORG rainfall measurements too largetwpsmet60sC2.b1
D080715.1TWP/SMET/C3 - Upper wind speed data incorrecttwpsmet60sC3.b1
D080922.5TWP/SMET/C3 - Missing datatwpsmet60sC3.b1
D081022.5TWP/SMET/C2 - Wind Speed data contain offset due to induced voltagetwpsmet60sC2.b1
D081022.7TWP/SMET/C3 - Wind Speed data contain offset due to induced voltagetwpsmet60sC3.a1
D081022.8TWP/SMET/C3 - Wind Speed data contain offset due to induced voltagetwpsmet60sC3.b1
D081027.2TWP/SMET/C2 - ORG rainrate high due to calibration.twpsmet60sC2.b1
D090129.4TWP/SMET/C3 - Reprocess: Station Pressure values reported in hPa instead of kPa.twpsmet60sC3.b1
D090225.3TWP/SMET/C3 - Reprocess: Temperature data biased lowtwpsmet60sC3.b1
D090515.1TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degreestwpsmet60sC3.b1
D090604.2TWP/SMET/C2 - Barometer data incorrecttwpsmet60sC2.b1
D090918.1TWP/SMET/C2 - Induced wind speed when calmtwpsmet60sC2.b1
D091023.1TWP/SMET/C3 - Tower Lowered for Maintenancetwpsmet60sC3.b1
D091030.2TWP/SMET/C2 - Tower Lowered for Maintenancetwpsmet60sC2.b1
D100303.3TWP/SMET/C2 - Barometer failuretwpsmet60sC2.b1


DQRID : D021211.1
Start DateStart TimeEnd DateEnd Time
08/21/2002000012/09/20020000
Subject:
TWP/SMET/C3 - Lower wind direction sensor misaligned
DataStreams:twpsmet60sC3.a1, twpsmet60sC3.b1
Description:
The lower wind direction sensor (sensor #2) was misaligned and off by 15 degrees.
Measurements:twpsmet60sC3.a1:
  • wind2_dir_sd
  • Wind #2 direction vector average(wind2_dir_vec_avg)

twpsmet60sC3.b1:
  • lo_dir_sd
  • lo_dir_vec_avg


Back To Table of Contents

DQRID : D030212.1
Start DateStart TimeEnd DateEnd Time
10/23/2002000002/06/20032203
Subject:
TWP/SMET/C3 - Intermittent Pressure Sensor Failure
DataStreams:twpsmet60sC3.a1, twpsmet60sC3.b1
Description:
The Barometric Pressure sensor was intermittently failing at TWP site C3 Darwin.  At times 
there were large pressure fluctuations occurring on the order of 24 mb in a few minutes. 
 Times of large pressure fluctuations are readily apparent in the data.  At these times 
the data should be carefully analyzed before determining it's usefulness.  In between the 
periods of large fluctuations the readings appear to be stable.  It is still suggested 
that independent pressure data be obtained for comparison before use.
Measurements:twpsmet60sC3.a1:
  • Barometric Pressure(atmos_pressure)

twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031103.2
Start DateStart TimeEnd DateEnd Time
03/12/2002062806/03/20022359
Subject:
TWP/SMET/C3 - Data reported at 15sec rather than 60s intervals
DataStreams:twpsmet60sC3.a1, twpsmet60sC3.b1
Description:
Data in these data streams should be reported at 60sec intervals, but
the logger program running during this time had the interval set to
15s.  Users will have to average the 15sec data to get 60sec data.
Measurements:twpsmet60sC3.a1:
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • Wind #2 speed maximum(wind2_spd_max)
  • Wind #2 speed maximum gust(wind2_spd_max_gust)
  • wind2_spd_sd
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Precipitation mean(precip_mean)
  • time_offset
  • vappress_sd
  • Wind #1 speed minimum(wind1_spd_min)
  • wind1_dir_sd
  • Temperature maximum(temp_max)
  • logger_temp
  • wind2_dir_sd
  • Wind #2 speed vector average(wind2_spd_vec_avg)
  • internal_voltage
  • bit_data
  • Wind #2 speed minimum(wind2_spd_min)
  • Precipitation maximum(precip_max)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Barometric Pressure(atmos_pressure)
  • Relative humidity maximum(relh_max)
  • Vapor pressure mean(vappress_mean)
  • Relative humidity minimum(relh_min)
  • temp_sd
  • Temperature minimum(temp_min)
  • relh_sd
  • Wind #1 direction vector average(wind1_dir_vec_avg)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • external_voltage
  • Precipitation minimum(precip_min)
  • Wind #2 direction vector average(wind2_dir_vec_avg)
  • Wind #2 speed arithmetic average(wind2_spd_arith_avg)
  • wind1_spd_sd
  • precip_sd
  • Relative humidity mean(relh_mean)
  • Wind #1 speed maximum(wind1_spd_max)

twpsmet60sC3.b1:
  • lo_dir_sd
  • Vapor pressure mean(vappress_mean)
  • logger_temp
  • up_spd_max
  • up_spd_min
  • precip_sd
  • lo_spd_min
  • temp_sd
  • relh_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • up_spd_sd
  • lo_dir_vec_avg
  • lo_spd_arith_avg
  • tbrg_total
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Precipitation mean(precip_mean)
  • up_dir_vec_avg
  • tbrg_count_total
  • time_offset
  • Relative humidity mean(relh_mean)
  • lo_spd_sd
  • lo_spd_vec_avg
  • Barometric Pressure(atmos_pressure)
  • up_spd_arith_avg
  • lo_spd_max
  • vappress_sd
  • up_spd_vec_avg
  • up_dir_sd
  • time
  • internal_voltage


Back To Table of Contents

DQRID : D040722.4
Start DateStart TimeEnd DateEnd Time
01/01/2004000005/17/20042259
Subject:
TWP/SMET/C3 - Rain blocked pressure port
DataStreams:twpsmet60sC3.b1
Description:
Atmospheric pressure values were suspect due to anomolous readings during heavy rain 
events.  Suspect blockage of port due to rainfall.  New logger and enclosure corrected problem.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D040726.3
Start DateStart TimeEnd DateEnd Time
03/12/2002062805/17/20042300
Subject:
TWP/SMET/C3 - Negative rainfall rates
DataStreams:twpsmet60sC3.b1
Description:
Due to limitations of the Zeno dataloggers all voltage measurements
from the optical rain gauge (ORG) were converted to rainfall rates. 
This resulted in negative values for rain rates.  Any value below
0.10 mm/hr should be considered to be 0 mm/hr.  New dataloggers 
alleviated this problem.
Measurements:twpsmet60sC3.b1:
  • precip_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D040726.4
Start DateStart TimeEnd DateEnd Time
03/12/2002062803/03/20032359
Subject:
TWP/SMET/C3 - Negative rainfall rates
DataStreams:twpsmet60sC3.a1
Description:
Due to limitations of the Zeno dataloggers all voltage measurements
from the optical rain gauge (ORG) were converted to rainfall rates. 
This resulted in negative values for rain rates.  Any value below
0.10 mm/hr should be considered to be 0 mm/hr.  New dataloggers 
alleviated this problem.
Measurements:twpsmet60sC3.a1:
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • precip_sd
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D050210.1
Start DateStart TimeEnd DateEnd Time
02/09/2005231002/09/20052320
Subject:
TWP/SMET/C3 - Data non-representative
DataStreams:twpsmet60sC3.b1
Description:
Tower mast was lowered for inspection.  Data during this time is non-representative.
Measurements:twpsmet60sC3.b1:
  • lo_dir_sd
  • tbrg_count_total
  • Vapor pressure mean(vappress_mean)
  • Relative humidity mean(relh_mean)
  • up_spd_max
  • up_spd_min
  • lo_spd_sd
  • lo_spd_vec_avg
  • precip_sd
  • lo_spd_min
  • Barometric Pressure(atmos_pressure)
  • temp_sd
  • up_spd_arith_avg
  • lo_spd_max
  • vappress_sd
  • up_spd_vec_avg
  • relh_sd
  • up_dir_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • up_spd_sd
  • lo_dir_vec_avg
  • lo_spd_arith_avg
  • tbrg_total
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Precipitation mean(precip_mean)
  • up_dir_vec_avg


Back To Table of Contents

DQRID : D050322.2
Start DateStart TimeEnd DateEnd Time
03/09/2005230004/17/20050332
Subject:
TWP/SMET/C2 - Upper wind direction sensor failure
DataStreams:twpsmet60sC2.b1
Description:
After replacement on 03/03/2005 the upper wind direction sensor began reporting erroneous 
values again on 03/09/2005 becoming very apparent after 03/17/2005.  Wind speed data 
appears reasonable but the wind direction data do not agree well with the lower wind sensor.
Measurements:twpsmet60sC2.b1:
  • up_dir_vec_avg
  • up_dir_sd


Back To Table of Contents

DQRID : D050418.2
Start DateStart TimeEnd DateEnd Time
04/14/2005023004/19/20050050
Subject:
TWP/SMET/C3 - Lower wind direction sensor failure
DataStreams:twpsmet60sC3.b1
Description:
The lower wind direction sensor failed on 4/14 and disagrees significantly with the upper 
wind direction sensor.  The lower wind sensor reports a constant value around 0-15 
degrees since it failed.  Testing showed that excitation channel two on the logger was the 
problem.  Logger was replaced by spare.
Measurements:twpsmet60sC3.b1:
  • lo_dir_sd
  • lo_dir_vec_avg


Back To Table of Contents

DQRID : D050714.1
Start DateStart TimeEnd DateEnd Time
07/10/2005190007/14/20052226
Subject:
TWP/SMET/C2 - RH sensor failure
DataStreams:twpsmet60sC2.b1
Description:
Relative humidity values were frequently over MAX value of 104% starting on 7/10/2005 
through end of period.  Sensor was replaced.
Measurements:twpsmet60sC2.b1:
  • relh_sd
  • Relative humidity mean(relh_mean)


Back To Table of Contents

DQRID : D050808.3
Start DateStart TimeEnd DateEnd Time
08/05/2005003008/05/20050330
Subject:
TWP/SMET/C3 - Data not representative
DataStreams:twpsmet60sC3.b1
Description:
Tower was lowered for radiometer change and characterization. Data are not representative 
of local conditions.
Measurements:twpsmet60sC3.b1:
  • lo_dir_sd
  • tbrg_count_total
  • Vapor pressure mean(vappress_mean)
  • Relative humidity mean(relh_mean)
  • up_spd_max
  • up_spd_min
  • lo_spd_vec_avg
  • lo_spd_sd
  • precip_sd
  • lo_spd_min
  • Barometric Pressure(atmos_pressure)
  • temp_sd
  • up_spd_arith_avg
  • lo_spd_max
  • vappress_sd
  • up_spd_vec_avg
  • relh_sd
  • up_dir_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • up_spd_sd
  • lo_dir_vec_avg
  • lo_spd_arith_avg
  • tbrg_total
  • Precipitation mean(precip_mean)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • up_dir_vec_avg


Back To Table of Contents

DQRID : D050920.4
Start DateStart TimeEnd DateEnd Time
09/21/2005162509/21/20051815
Subject:
TWP/SMET/C2 - Instrument maintenance
DataStreams:twpsmet60sC2.b1
Description:
Instrument calibration and testing were taking place for brief periods.
Measurements:twpsmet60sC2.b1:
  • vappress_sd
  • lo_spd_arith_avg
  • lo_dir_vec_avg
  • lo_spd_vec_avg
  • Vapor pressure mean(vappress_mean)
  • up_spd_min
  • up_dir_sd
  • up_spd_max
  • Mean Air Temperature or Hardware Error(temp_mean)
  • tbrg_count_total
  • Precipitation maximum(precip_max)
  • up_spd_arith_avg
  • lo_spd_sd
  • relh_sd
  • lo_spd_min
  • temp_sd
  • up_dir_vec_avg
  • precip_sd
  • Barometric Pressure(atmos_pressure)
  • lo_dir_sd
  • up_spd_vec_avg
  • Precipitation mean(precip_mean)
  • Precipitation minimum(precip_min)
  • tbrg_total
  • Relative humidity mean(relh_mean)
  • lo_spd_max
  • up_spd_sd


Back To Table of Contents

DQRID : D050921.2
Start DateStart TimeEnd DateEnd Time
09/19/2005080909/19/20051902
Subject:
TWP/SMET/C2 - ORG data incorrect
DataStreams:twpsmet60sC2.b1
Description:
Data from the ORG was incorrect due to heavy condensation on the lens.
Measurements:twpsmet60sC2.b1:
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • precip_sd


Back To Table of Contents

DQRID : D051005.6
Start DateStart TimeEnd DateEnd Time
09/19/2005020009/19/20050330
Subject:
TWP/SMET/C2 - Tower down for calibration activities
DataStreams:twpsmet60sC2.b1
Description:
Tower lowered, wind vanes spun at different frequencies, and ORG tested with electronic 
rain.
Measurements:twpsmet60sC2.b1:
  • vappress_sd
  • Temperature maximum(temp_max)
  • Wind #1 speed minimum(wind1_spd_min)
  • wind1_dir_sd
  • Wind #2 speed arithmetic average(wind2_spd_arith_avg)
  • Vapor pressure mean(vappress_mean)
  • wind1_spd_sd
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Precipitation maximum(precip_max)
  • Wind #1 direction vector average(wind1_dir_vec_avg)
  • Wind #2 direction vector average(wind2_dir_vec_avg)
  • Wind #2 speed maximum(wind2_spd_max)
  • relh_sd
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • temp_sd
  • Temperature minimum(temp_min)
  • precip_sd
  • Wind #2 speed minimum(wind2_spd_min)
  • Wind #1 speed maximum(wind1_spd_max)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Wind #2 speed vector average(wind2_spd_vec_avg)
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • wind2_spd_sd
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Relative humidity mean(relh_mean)
  • Wind #2 speed maximum gust(wind2_spd_max_gust)
  • wind2_dir_sd
  • Relative humidity maximum(relh_max)
  • Relative humidity minimum(relh_min)


Back To Table of Contents

DQRID : D051115.1
Start DateStart TimeEnd DateEnd Time
11/14/2005045311/15/20052215
Subject:
TWP/SMET/C3 - Upper wind sensor failure
DataStreams:twpsmet60sC3.b1
Description:
A lightning strike destroyed the upper wind sensor.
Measurements:twpsmet60sC3.b1:
  • up_spd_vec_avg
  • up_dir_sd
  • up_spd_max
  • up_spd_sd
  • up_spd_min
  • up_spd_arith_avg
  • up_dir_vec_avg


Back To Table of Contents

DQRID : D051117.2
Start DateStart TimeEnd DateEnd Time
11/14/2005045311/15/20050050
Subject:
TWP/SMET/C3 - RH Values Artificially High
DataStreams:twpsmet60sC3.b1
Description:
Lightning strike caused RH readings to be higher than reasonable (130%).
Measurements:twpsmet60sC3.b1:
  • relh_sd
  • Vapor pressure mean(vappress_mean)
  • vappress_sd
  • Relative humidity mean(relh_mean)


Back To Table of Contents

DQRID : D051117.3
Start DateStart TimeEnd DateEnd Time
11/14/2005045311/23/20050000
Subject:
TWP/SMET/C3 - Instrument failure
DataStreams:twpsmet60sC3.b1
Description:
A lightning strike caused a failure in the ORG.  Rainfall was being continually recorded.
Measurements:twpsmet60sC3.b1:
  • precip_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D060426.8
Start DateStart TimeEnd DateEnd Time
12/01/2005000008/24/20062359
Subject:
TWP/SMET/C3 - ORG data noisy due to degraded ground
DataStreams:twpsmet60sC3.b1
Description:
SMET Rain Data began to be noisy during December 2005 and the problem slowly became worse 
over time so that in February 2006 the ORG was reporting with a constant background value 
of around 0.10 mm/hr rain rate.  ORG voltage showed a near constant value above the 85mV 
threshold.  The ground for the ORG had become degraded and was lost due to corrosion.
Measurements:twpsmet60sC3.b1:
  • precip_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D060502.3
Start DateStart TimeEnd DateEnd Time
04/27/2006233005/02/20060201
Subject:
TWP/SMET/C3 - Reprocessed: Lower windspeed sensor calibration error
DataStreams:twpsmet60sC3.b1
Description:
The lower anemometer was replaced but the calibration coefficients were not changed during 
this period.  The data were reprocessed to apply the correct calibrations and the 
reprocessed data were archived in August 2008.
Measurements:twpsmet60sC3.b1:
  • lo_spd_vec_avg
  • lo_spd_sd
  • lo_spd_min
  • lo_spd_arith_avg
  • lo_spd_max


Back To Table of Contents

DQRID : D060614.2
Start DateStart TimeEnd DateEnd Time
06/05/2006214406/15/20060427
Subject:
TWP/SMET/C2 - Temp/RH probe failure
DataStreams:twpsmet60sC2.b1
Description:
Temperature/RH probe failed and was replaced.
Measurements:twpsmet60sC2.b1:
  • vappress_sd
  • relh_sd
  • temp_sd
  • Vapor pressure mean(vappress_mean)
  • Relative humidity mean(relh_mean)
  • Mean Air Temperature or Hardware Error(temp_mean)


Back To Table of Contents

DQRID : D060627.1
Start DateStart TimeEnd DateEnd Time
06/27/2006011506/27/20060344
Subject:
TWP/SMET/C3 - Data not representative
DataStreams:twpsmet60sC3.b1
Description:
The Anemometer readings were incorrect due to the tower being lowered for maintenance.
Measurements:twpsmet60sC3.b1:
  • lo_spd_sd
  • lo_spd_vec_avg
  • lo_spd_min
  • lo_dir_sd
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_vec_avg
  • up_dir_sd
  • up_spd_max
  • lo_dir_vec_avg
  • up_spd_min
  • up_spd_sd
  • lo_spd_arith_avg
  • up_dir_vec_avg


Back To Table of Contents

DQRID : D060818.3
Start DateStart TimeEnd DateEnd Time
12/02/2003000005/19/20042359
Subject:
TWP/SMET/C3 - Reprocess: Barometric pressure units change
DataStreams:twpsmet60sC3.b1
Description:
Barometric pressure data during this time period is reported in hPa.  After this time, the 
data have been converted to kPa to standardize the measurement units among ARM sites and 
to conform to accepted standard units determined by the scientific community.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.3
Start DateStart TimeEnd DateEnd Time
10/21/1998000011/29/20062014
Subject:
TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC2.b1
Description:
A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. 
Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC2.b1 datastream.  Between 9/26 and 11/29, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros are 
not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19981021-20060926 and data from 
19981021-20061129 will be filled with -9999 (missing).
Measurements:twpsmet60sC2.b1:
  • base_time


Back To Table of Contents

DQRID : D061011.4
Start DateStart TimeEnd DateEnd Time
03/12/2002000009/26/20061435
Subject:
TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC3.b1
Description:
A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. 
 Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 
datastream.  When reprocessing of this datastream occurs these variables will be added 
with -9999 (missing) as the value for dates prior to gauge installation.
Measurements:twpsmet60sC3.b1:
  • base_time


Back To Table of Contents

DQRID : D061214.2
Start DateStart TimeEnd DateEnd Time
12/07/2006194101/23/20070023
Subject:
TWP/SMET/C2 - Barometer failure
DataStreams:twpsmet60sC2.b1
Description:
The barometer began experiencing problems with noise resulting in incorrect data.  The 
problem becames worse over time; after 12/19/2006 @0151 GMT the barometer data is completely 
missing.  The barometer was replaced.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D070306.2
Start DateStart TimeEnd DateEnd Time
03/02/2007172303/03/20071228
Subject:
TWP/SMET/C3 - Barometer Data Incorrect
DataStreams:twpsmet60sC3.b1
Description:
The barometer data was incorrect or missing due to water intrusion.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D070306.3
Start DateStart TimeEnd DateEnd Time
03/03/2007005603/03/20070123
Subject:
TWP/SMET/C3 - Water in enclosure
DataStreams:twpsmet60sC3.b1
Description:
Data became erratic and unreasonable after water intrusion into the enclosure.
Measurements:twpsmet60sC3.b1:
  • relh_sd
  • precip_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • temp_sd
  • Vapor pressure mean(vappress_mean)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Precipitation mean(precip_mean)
  • vappress_sd
  • Relative humidity mean(relh_mean)


Back To Table of Contents

DQRID : D070510.5
Start DateStart TimeEnd DateEnd Time
04/05/2007000008/19/20072135
Subject:
TWP/SMET/C2 - Lower windspeed sensor questionable
DataStreams:twpsmet60sC2.b1
Description:
Lower wind speed sensor had degraded bearings.  This sensor was reporting as much as 0.4 
m/s lower values than the upper sensors when the winds were 2 m/s or below.  The sensor 
was replaced.
Measurements:twpsmet60sC2.b1:
  • lo_spd_arith_avg
  • lo_spd_min
  • lo_spd_vec_avg
  • lo_spd_max
  • lo_spd_sd


Back To Table of Contents

DQRID : D070520.1
Start DateStart TimeEnd DateEnd Time
05/11/2007000005/22/20070047
Subject:
TWP/SMET/C2 - Lower Wind Sensor Direction Incorrect
DataStreams:twpsmet60sC2.b1
Description:
Wind directions between lower and upper anemometers were displaced by approximately 45 
degrees when a new sensor was installed to replace the failing lower winde sensor.  The new 
sensor direction data incorrect.
Measurements:twpsmet60sC2.b1:
  • lo_dir_vec_avg
  • lo_dir_sd


Back To Table of Contents

DQRID : D070803.1
Start DateStart TimeEnd DateEnd Time
07/01/2007000009/18/20072315
Subject:
TWP/SMET/C3 - Upper wind speed artificially slow
DataStreams:twpsmet60sC3.b1
Description:
The upper wind measurement was consistently slower by around 0.5 - 1 m/s than the lower 
wind measurement.  The bearings on the upper wind measurement were binding.
Measurements:twpsmet60sC3.b1:
  • up_spd_vec_avg
  • up_spd_max
  • up_spd_sd
  • up_spd_min
  • up_spd_arith_avg


Back To Table of Contents

DQRID : D071105.1
Start DateStart TimeEnd DateEnd Time
11/02/2007185511/02/20072010
Subject:
TWP/SMET/C3 - ORG overestimated rainfall
DataStreams:twpsmet60sC3.b1
Description:
Optical rain gauge (ORG) measured approximately 10mm higher than two co-located tipping 
bucket rain gauges and a co-located disdrometer.  The ORG is typically higher but usually 
not by an order of magnitude.
Measurements:twpsmet60sC3.b1:
  • precip_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D071219.1
Start DateStart TimeEnd DateEnd Time
05/22/2007004808/19/20072150
Subject:
TWP/SMET/C2 - Lower Wind Speed Data Suspect
DataStreams:twpsmet60sC2.b1
Description:
The lower wind speed bearings appeared to be binding at speeds below 2 m/s as it did not 
compare well with the upper wind sensor.
Measurements:twpsmet60sC2.b1:
  • lo_spd_arith_avg
  • lo_spd_min
  • lo_spd_vec_avg
  • lo_spd_max
  • lo_spd_sd


Back To Table of Contents

DQRID : D080225.1
Start DateStart TimeEnd DateEnd Time
01/05/2008000002/27/20080315
Subject:
TWP/SMET/C3 - Upper Wind Sensor Data Questionable
DataStreams:twpsmet60sC3.b1
Description:
The wind_up vs. wind_low wind directions diverged, with the differences between the two 
eventually reached 45 degrees. The Upper sensor was found to be mis-aligned and loose.
Measurements:twpsmet60sC3.b1:
  • up_spd_vec_avg
  • up_spd_max
  • up_spd_sd
  • up_spd_min
  • up_spd_arith_avg


Back To Table of Contents

DQRID : D080428.3
Start DateStart TimeEnd DateEnd Time
05/01/2004000006/30/20102359
Subject:
TWP/SMET/C3 - Reprocess: ORG Data has very small rainrate values
DataStreams:twpsmet60sC3.b1
Description:
The ORG data is collected via analog signal and not digital.  Therefore, we
continuously collect data even when no rain is occurring.  We also capture small events 
such as leaves, large bugs, dust, etc blowing through the measurement path.  Because this 
discrete event occurs quickly the value is usually captured for 1 or 2 seconds.  This 
value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less.  

These values are not indicative of rain and should be removed from the record or summing 
over long periods can bias the climate record.  We will reprocess the data to remove these 
small values.
Measurements:twpsmet60sC3.b1:
  • precip_sd
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)


Back To Table of Contents

DQRID : D080428.4
Start DateStart TimeEnd DateEnd Time
07/01/2004000006/30/20102359
Subject:
TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values
DataStreams:twpsmet60sC2.b1
Description:
The ORG data is collected via analog signal and not digital.  Therefore, we continuously 
collect data even when no rain is occurring.  We also capture small events such as leaves, 
large bugs, dust, etc blowing through the measurement path.  Because this discrete event 
occurs quickly the value is usually captured for 1 or 2 seconds.  This value is then 
averaged to the minute producing rainrate on the order of .009 mm/hr or less.  

These values are not indicative of rain and should be removed from the record or summing 
over long periods can bias the climate record.  We will reprocess the data to remove these 
small values.
Measurements:twpsmet60sC2.b1:
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • precip_sd


Back To Table of Contents

DQRID : D080611.2
Start DateStart TimeEnd DateEnd Time
05/27/2008194506/24/20080113
Subject:
TWP/SMET/C3 - Lower Wind Direction Intermittently Wrong
DataStreams:twpsmet60sC3.b1
Description:
The lower wind sensor cabling had a problem causing an intermittent connection for the 
wind direction data.
Measurements:twpsmet60sC3.b1:
  • lo_dir_sd
  • lo_dir_vec_avg


Back To Table of Contents

DQRID : D080617.1
Start DateStart TimeEnd DateEnd Time
05/08/2008000008/07/20082300
Subject:
TWP/SMET/C2 - ORG rainfall measurements too large
DataStreams:twpsmet60sC2.b1
Description:
The ORG was collecting large amounts of rainfall compared to the co-located tipping bucket 
raingauge.  The cable was chewed by mice causing the wires to make contact 
intermittently mimicking rainfall.
Measurements:twpsmet60sC2.b1:
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • precip_sd


Back To Table of Contents

DQRID : D080715.1
Start DateStart TimeEnd DateEnd Time
07/08/2008204507/17/20080144
Subject:
TWP/SMET/C3 - Upper wind speed data incorrect
DataStreams:twpsmet60sC3.b1
Description:
Beginning on 07/08, the upper wind sensor started reporting significantly lower wind 
speeds than the lower wind sensor.  The cable connections weather proofing failed allowing 
corrosion to occur and increasing he resistance of the cables.  This in turn lowered the 
wind speeds artificially.
Measurements:twpsmet60sC3.b1:
  • up_spd_vec_avg
  • up_spd_max
  • up_spd_sd
  • up_spd_min
  • up_spd_arith_avg


Back To Table of Contents

DQRID : D080922.5
Start DateStart TimeEnd DateEnd Time
05/17/2004220205/19/20040559
04/23/2006235704/27/20060348
Subject:
TWP/SMET/C3 - Missing data
DataStreams:twpsmet60sC3.b1
Description:
Data are missing and unrecoverable.
Measurements:twpsmet60sC3.b1:
  • alt
  • lo_dir_sd
  • lon
  • base_time
  • tbrg_count_total
  • time_offset
  • Vapor pressure mean(vappress_mean)
  • Relative humidity mean(relh_mean)
  • logger_temp
  • up_spd_max
  • up_spd_min
  • lo_spd_vec_avg
  • lo_spd_sd
  • precip_sd
  • lo_spd_min
  • Barometric Pressure(atmos_pressure)
  • temp_sd
  • lat
  • up_spd_arith_avg
  • lo_spd_max
  • vappress_sd
  • up_spd_vec_avg
  • relh_sd
  • up_dir_sd
  • time
  • Precipitation maximum(precip_max)
  • Precipitation minimum(precip_min)
  • up_spd_sd
  • lo_dir_vec_avg
  • internal_voltage
  • lo_spd_arith_avg
  • tbrg_total
  • Precipitation mean(precip_mean)
  • Mean Air Temperature or Hardware Error(temp_mean)
  • up_dir_vec_avg


Back To Table of Contents

DQRID : D081022.5
Start DateStart TimeEnd DateEnd Time
11/01/1998000002/23/20090410
Subject:
TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC2.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC2.b1:
  • lo_spd_arith_avg
  • lo_spd_min
  • lo_spd_vec_avg
  • up_spd_min
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_sd
  • up_spd_max
  • lo_spd_sd
  • up_spd_vec_avg


Back To Table of Contents

DQRID : D081022.7
Start DateStart TimeEnd DateEnd Time
03/12/2002000003/03/20032359
Subject:
TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC3.a1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC3.a1:
  • Wind #2 speed arithmetic average(wind2_spd_arith_avg)
  • Wind #2 speed vector average(wind2_spd_vec_avg)
  • wind1_spd_sd
  • Wind #2 speed minimum(wind2_spd_min)
  • Wind #1 speed arithmetic average(wind1_spd_arith_avg)
  • Wind #2 speed maximum gust(wind2_spd_max_gust)
  • Wind #2 speed maximum(wind2_spd_max)
  • wind2_spd_sd
  • Wind #1 speed minimum(wind1_spd_min)
  • Wind #1 speed vector average(wind1_spd_vec_avg)
  • Wind #1 speed maximum gust(wind1_spd_max_gust)
  • Wind #1 speed maximum(wind1_spd_max)


Back To Table of Contents

DQRID : D081022.8
Start DateStart TimeEnd DateEnd Time
03/12/2002000010/17/20080627
Subject:
TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage
DataStreams:twpsmet60sC3.b1
Description:
The marine model of the RM Young wind sensor needs twisted pair shielded cable.  The 
manufacturer did not originally supply the pigtail with twisted pair shielded cable.  Use of 
twisted pair shielded cable for the rest of the cable run to the logger was also not 
specified.  This caused an induced voltage in the wind speed line from the wind direction 
excitation.  The induced voltage varied from sensor to sensor and probably changed anytime 
the cable was replaced or parts of the wind sensor were repaired or replaced. The induced 
voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s.
Measurements:twpsmet60sC3.b1:
  • up_spd_vec_avg
  • lo_spd_vec_avg
  • lo_spd_sd
  • lo_spd_min
  • up_spd_max
  • up_spd_sd
  • up_spd_min
  • lo_spd_arith_avg
  • up_spd_arith_avg
  • lo_spd_max


Back To Table of Contents

DQRID : D081027.2
Start DateStart TimeEnd DateEnd Time
10/05/2008231110/05/20082344
Subject:
TWP/SMET/C2 - ORG rainrate high due to calibration.
DataStreams:twpsmet60sC2.b1
Description:
The rainrate from the ORG was high due to calibration.  This data is not real.
Measurements:twpsmet60sC2.b1:
  • Precipitation minimum(precip_min)
  • Precipitation mean(precip_mean)
  • Precipitation maximum(precip_max)
  • precip_sd


Back To Table of Contents

DQRID : D090129.4
Start DateStart TimeEnd DateEnd Time
01/27/2009185001/30/20091535
Subject:
TWP/SMET/C3 - Reprocess: Station Pressure values reported in hPa instead of kPa.
DataStreams:twpsmet60sC3.b1
Description:
An incorrect program was entered into the datalogger.  This program did not convert the 
station pressure from hPa to kPa.  This made the values larger by a factor of 10 and caused 
the QC bit to be tripped.
Measurements:twpsmet60sC3.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D090225.3
Start DateStart TimeEnd DateEnd Time
05/19/2004051904/19/20050419
Subject:
TWP/SMET/C3 - Reprocess: Temperature data biased low
DataStreams:twpsmet60sC3.b1
Description:
Due to a datalogger problem, the temperature data were biased low by 2.13 degrees C.

The data will be reprocessed.
Measurements:twpsmet60sC3.b1:
  • temp_sd
  • Mean Air Temperature or Hardware Error(temp_mean)


Back To Table of Contents

DQRID : D090515.1
Start DateStart TimeEnd DateEnd Time
04/19/2005042004/04/20090115
Subject:
TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degrees
DataStreams:twpsmet60sC3.b1
Description:
The temperature of the SMET system was biased low by 1.06 Deg C due to a non-precision 
resistor being used int he measurement circuit.  The data will be reprocessed.  Saturation 
Vapor pressure and Vapor pressure will have to be reprocessed also.

Add 1.06 degrees to the temperature data.  

Correct Sat Vap Press using the Buck approximation:
   Es = 6.1121exp((17.502*T)/(240.97 + T) 
where T is the temperature in C.  

Correct Vapor pressure using: E = (RH*Es)/100
Measurements:twpsmet60sC3.b1:
  • temp_sd
  • Mean Air Temperature or Hardware Error(temp_mean)
  • Vapor pressure mean(vappress_mean)
  • vappress_sd


Back To Table of Contents

DQRID : D090604.2
Start DateStart TimeEnd DateEnd Time
05/20/2009000406/05/20092359
Subject:
TWP/SMET/C2 - Barometer data incorrect
DataStreams:twpsmet60sC2.b1
Description:
Beginning 05/20, atmos_pressure exceeded MAX between ~21:00 and 01:00 UTC on most days.  
The inlet tube was accidentally pinched in the door of the logger enclosure artificially 
increasing the atmospheric pressure during the listed times.  Only a few hours exceeded 
max limits.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D090918.1
Start DateStart TimeEnd DateEnd Time
07/01/2009010010/15/20090300
Subject:
TWP/SMET/C2 - Induced wind speed when calm
DataStreams:twpsmet60sC2.b1
Description:
The upper and lower wind sensors were not trending well at wind speed below 1 m/s.  Both 
sensors were showing values above 0m/s when calm.  The lightning protector was at fault 
resulting in an induced wind voltage during calm conditions.

Users should subtract any offset found (for example 0.19 m/s for upper wind speed) when 
the wind speeds are flat-lined.  The offset value was not consistent.
Measurements:twpsmet60sC2.b1:
  • lo_spd_arith_avg
  • lo_spd_min
  • lo_spd_vec_avg
  • up_spd_min
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_max
  • up_spd_vec_avg


Back To Table of Contents

DQRID : D091023.1
Start DateStart TimeEnd DateEnd Time
09/30/2009004509/30/20090500
Subject:
TWP/SMET/C3 - Tower Lowered for Maintenance
DataStreams:twpsmet60sC3.b1
Description:
The tower was lowered for annual anemometer changes.  The wind data is suspect.
Measurements:twpsmet60sC3.b1:
  • lo_spd_sd
  • lo_spd_vec_avg
  • lo_spd_min
  • lo_dir_sd
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_vec_avg
  • up_dir_sd
  • up_spd_max
  • lo_dir_vec_avg
  • up_spd_min
  • up_spd_sd
  • lo_spd_arith_avg
  • up_dir_vec_avg


Back To Table of Contents

DQRID : D091030.2
Start DateStart TimeEnd DateEnd Time
10/14/2009215010/15/20090315
Subject:
TWP/SMET/C2 - Tower Lowered for Maintenance
DataStreams:twpsmet60sC2.b1
Description:
Data is suspect due to the tower being lowered.
Measurements:twpsmet60sC2.b1:
  • vappress_sd
  • lo_spd_arith_avg
  • relh_sd
  • lo_spd_min
  • lo_dir_vec_avg
  • temp_sd
  • up_dir_vec_avg
  • lo_spd_vec_avg
  • Vapor pressure mean(vappress_mean)
  • up_spd_min
  • up_dir_sd
  • up_spd_max
  • Mean Air Temperature or Hardware Error(temp_mean)
  • up_spd_vec_avg
  • lo_dir_sd
  • Relative humidity mean(relh_mean)
  • up_spd_arith_avg
  • lo_spd_max
  • up_spd_sd
  • lo_spd_sd


Back To Table of Contents

DQRID : D100303.3
Start DateStart TimeEnd DateEnd Time
02/04/2010060002/23/20102315
Subject:
TWP/SMET/C2 - Barometer failure
DataStreams:twpsmet60sC2.b1
Description:
The atmos_pressure values were spiking high (up to 110 kPa) from 06:00 UTC on 02/04 until 
the data went missing at 10:44 UTC on 02/06 when the barometer failed completely.

Barometer replaced 2/23.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents



END OF DATA