DQR ID | Subject | Data Streams Affected |
---|---|---|
D121005.1 | PVC/GNDRAD/M1 - Reprocess: Incorrect calibration | pvcgndrad20sM1.a0, pvcgndrad60sM1.b1 |
D121218.4 | PVC/GNDRAD/M1 - IRT failure | pvcgndrad20sM1.a0, pvcgndrad60sM1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/25/2012 | 0000 | 10/04/2012 | 2017 |
Subject: | PVC/GNDRAD/M1 - Reprocess: Incorrect calibration |
DataStreams: | pvcgndrad20sM1.a0, pvcgndrad60sM1.b1 |
Description: | Incorrect program used in Gndrad since PVC deployment period began. The Gndrad program was corrected 10/04/2012 approx 20:17GMT. Reprocessing will be required of the upwelling PSP (up_short_hemsip). This will require applying the following corrections for the time range specified. Serial number: serial number(original) = 30938 serial number(corrected) = 37297 Data: up_short_hemip(corrected) = up_short_hemisp(original)*(113.25(new cal)/129.42(old cal)) |
Measurements: | pvcgndrad60sM1.b1:
pvcgndrad20sM1.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/26/2012 | 0000 | 12/11/2012 | 1556 |
Subject: | PVC/GNDRAD/M1 - IRT failure |
DataStreams: | pvcgndrad20sM1.a0, pvcgndrad60sM1.b1 |
Description: | The IRT failed but continued producing a misleading analog signal. The ground surface temperature measurements were unrepresentative of the actual temperature. |
Measurements: | pvcgndrad60sM1.b1:
pvcgndrad20sM1.a0:
|