DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D140306.1 | TWP/ECOR/E30 - Sonic Anemometer Not Working. Data not available. | twp30ecorE30.b1 | Missing |
D140307.4 | TWP/ECOR/E30 - CO2 Flux and Latent Heat flux Incorrect | twp30ecorE30.b1 | Incorrect |
D140507.2 | TWP/ECOR/E31 - Reprocessing Notice (RID 1121) | twp30ecorE31.b1 | Does not affect quality |
D140801.2 | TWP/ECOR/E31 - Data Missing | twp30ecorE31.b1 | Missing |
D140925.1 | TWP/ECOR/E31 - Data Missing | twp30ecorE31.b1 | Missing |
D141107.7 | TWP/ECOR/E32 - Sensible and Latent Heat Fluxes Incorrect | twp30ecorE32.b1 | Incorrect |
D141113.1 | TWP/ECOR/E31 - Pressure and Temperature Missing | twp30ecorE31.b1 | Missing |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/06/2014 | 2030 | 02/20/2014 | 1400 | Missing |
Subject: | TWP/ECOR/E30 - Sonic Anemometer Not Working. Data not available. |
DataStreams: | twp30ecorE30.b1 |
Description: | The instrument program would not run because the sonic anemometer was not functioning. Therefore, no instrument data available. |
Measurements: | twp30ecorE30.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/20/2014 | 1430 | 03/07/2014 | 0130 | Incorrect |
Subject: | TWP/ECOR/E30 - CO2 Flux and Latent Heat flux Incorrect |
DataStreams: | twp30ecorE30.b1 |
Description: | The IRGA power cycled to make the serial data stream visible to the computer. CO2 Flux and Latent Heat flux are incorrect during the indicated period. |
Measurements: | twp30ecorE30.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/01/2014 | 0330 | 05/06/2014 | 0100 | Does not affect quality |
Subject: | TWP/ECOR/E31 - Reprocessing Notice (RID 1121) |
DataStreams: | twp30ecorE31.b1 |
Description: | See below for details of reprocessing that was completed on 20141028. Original DQR category: 4 (Red, Incorrect). ----------------------------------------------------------- The Mean Water Vapor Density and ground analog signal leads were switched. This resulted in: 1) The sign of Latent Heat Flux and Mean Water Vapor Density being reversed 2) Mean CO2 density concentration being referenced to the Mean Water Vapor Density signal instead of to ground. |
Measurements: | twp30ecorE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/25/2014 | 1000 | 07/28/2014 | 1330 | Missing |
Subject: | TWP/ECOR/E31 - Data Missing |
DataStreams: | twp30ecorE31.b1 |
Description: | Data missing for this period. |
Measurements: | twp30ecorE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/16/2014 | 0600 | 09/24/2014 | 1330 | Missing |
Subject: | TWP/ECOR/E31 - Data Missing |
DataStreams: | twp30ecorE31.b1 |
Description: | All data missing. |
Measurements: | twp30ecorE31.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/28/2014 | 0530 | 11/07/2014 | 0030 | Incorrect |
Subject: | TWP/ECOR/E32 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | twp30ecorE32.b1 |
Description: | The sonic anemometer is not working, resulting in sensible and latent heat fluxes, momentum flux, and wind speed and direction to be incorrect. |
Measurements: | twp30ecorE32.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/06/2014 | 0000 | 11/13/2014 | 0030 | Missing |
Subject: | TWP/ECOR/E31 - Pressure and Temperature Missing |
DataStreams: | twp30ecorE31.b1 |
Description: | This problem did not affect the sensible heat , latent heat, or CO2 fluxes. |
Measurements: | twp30ecorE31.b1:
|