DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D090714.3 | SGP/SWATS/E11 - Incorrect soil moisture, 60cm E | sgpswatsE11.b1 | Incorrect |
D120712.1 | SGP/EBBR/E36 - Soil heat flow #3 too shallow | sgp30ebbrE36.b1 | Suspect |
D120821.1 | SGP/EBBR/E34 - Net radiometer cable failure | sgp30ebbrE34.b1 | Incorrect |
D150727.9 | SGP/SWATS/E33 - Measurements at Several Depths Are Suspect | sgpswatsE33.b1 | Suspect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/12/2009 | 1600 | 02/25/2016 | 1400 | Incorrect |
Subject: | SGP/SWATS/E11 - Incorrect soil moisture, 60cm E |
DataStreams: | sgpswatsE11.b1 |
Description: | All trise values from the 60 cm E sensor are incorrectly reporting near zero. This also causes the matric potential (soilwatpot_E) and water content (watcont_E) data to be incorrect at this depth. |
Measurements: | sgpswatsE11.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/06/2012 | 1830 | 06/12/2012 | 2030 | Suspect |
Subject: | SGP/EBBR/E36 - Soil heat flow #3 too shallow |
DataStreams: | sgp30ebbrE36.b1 |
Description: | Soil heat flow sensor #3 was too close to the soil surface. Sensible and latent heat fluxes may have been slightly too small as a result. |
Measurements: | sgp30ebbrE36.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/23/2012 | 0230 | 08/13/2012 | 1730 | Incorrect |
Subject: | SGP/EBBR/E34 - Net radiometer cable failure |
DataStreams: | sgp30ebbrE34.b1 |
Description: | Sensible and latent heat fluxes were incorrect because an animal chewed through the net radiometer cable. |
Measurements: | sgp30ebbrE34.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/15/2012 | 0000 | 02/23/2016 | 1400 | Suspect |
Subject: | SGP/SWATS/E33 - Measurements at Several Depths Are Suspect |
DataStreams: | sgpswatsE33.b1 |
Description: | Measurements at several depths are suspect because of probe failures: 5cm E 15cm E 35cm E 85cm E 125cm E 125cm W 175cm W |
Measurements: | sgpswatsE33.b1:
|