DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D160225.1 | AWR/GVRP/S1 - Biased brightness temperatures | awrgvrpS1.b1 | Incorrect |
D160225.2 | AWR/GVRP/S1 - Reprocessing Notice (RID 1438) | awrgvrpS1.b1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/24/2015 | 0500 | 01/17/2016 | 2200 | Incorrect |
Subject: | AWR/GVRP/S1 - Biased brightness temperatures |
DataStreams: | awrgvrpS1.b1 |
Description: | The calibration of the instrument suddenly changed affecting the brightness temperatures |
Measurements: | awrgvrpS1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/20/2015 | 0000 | 01/17/2016 | 2200 | Does not affect quality |
Subject: | AWR/GVRP/S1 - Reprocessing Notice (RID 1438) |
DataStreams: | awrgvrpS1.b1 |
Description: | DATA REPROCESSED. Data was reprocessed on 20160324 to fix issues noted in the original DQR copied below. -------------------------------------------------------------------------------- The altitude of the site was outside of the range of the pressure sensor quality control limits. The lowest data quality limit (valid_min) should be set to 750 mb. |
Measurements: | awrgvrpS1.b1:
|