D140820.4TWP/MERGESONDE/C1 - Reprocess: Suspect rh_scaled valuestwpmergesonde1maceC1.c1Suspect
D140821.4NSA/MERGESONDE/C1 - Reprocess: Suspect rh_scaled valuesnsamergesonde1maceC1.c1Suspect
D140822.10GRW/MERGESONDE/M1 - Reprocessing Notice (RID 1224)grwmergesonde1maceM1.c1Does not affect quality
D140822.13NIM/MERGESONDE/M1 - Suspect rh_scaled valuesnimmergesonde2maceM1.c1Suspect


DQRID : D140820.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
01/01/2000000012/31/20102359Suspect
Subject:
TWP/MERGESONDE/C1 - Reprocess: Suspect rh_scaled values
DataStreams:twpmergesonde1maceC1.c1
Description:
MERGESONDE sometimes uses bad or questionable precipitable water vapor data to scale the 
relative humidity profiles provided by the rh_scaled field. In addition, this bad input 
data is not properly indicated by the vapor_source or qc_rh_scaled fields. This problem 
appears to typically occur when there is moisture impacting the microwave radiometer causing 
large spikes in brightness temperatures. During these periods the rh_scaled values are 
often saturated at 101% for much of the profile.
Measurements:twpmergesonde1maceC1.c1:
  • rh_scaled
  • vapor_source


Back To Table of Contents

DQRID : D140821.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
01/01/2002000012/31/20102359Suspect
Subject:
NSA/MERGESONDE/C1 - Reprocess: Suspect rh_scaled values
DataStreams:nsamergesonde1maceC1.c1
Description:
MERGESONDE sometimes uses bad or questionable precipitable water vapor data to scale the 
relative humidity profiles provided by the rh_scaled field. In addition, this bad input 
data is not properly indicated by the vapor_source or qc_rh_scaled fields. This problem 
appears to typically occur when there is moisture impacting the microwave radiometer causing 
large spikes in brightness temperatures. During these periods the rh_scaled values are 
often saturated at 101% for much of the profile.
Measurements:nsamergesonde1maceC1.c1:
  • vapor_source
  • rh_scaled


Back To Table of Contents

DQRID : D140822.10
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/02/2009000012/30/20102359Does not affect quality
Subject:
GRW/MERGESONDE/M1 - Reprocessing Notice (RID 1224)
DataStreams:grwmergesonde1maceM1.c1
Description:
See below for details of reprocessing that was completed on 20150209.  Original DQR 
category: 3 (Yellow, Suspect).

-----------------------------------------------------------

MERGESONDE sometimes uses bad or questionable precipitable water vapor data to scale the 
relative humidity profiles provided by the rh_scaled field. In addition, this bad input 
data is not properly indicated by the vapor_source or qc_rh_scaled fields. This problem 
appears to typically occur when there is moisture impacting the microwave radiometer causing 
large spikes in brightness temperatures. During these periods the rh_scaled values are 
often saturated at 101% for much of the profile. 

A new version of the MERGESONDE VAP has corrected this problem, and these data will 
eventually be corrected by a reprocessing task.
Measurements:grwmergesonde1maceM1.c1:
  • rh_scaled
  • vapor_source


Back To Table of Contents

DQRID : D140822.13
Start DateStart TimeEnd DateEnd Time Data Quality Metric
01/10/2006000001/07/20072359Suspect
Subject:
NIM/MERGESONDE/M1 - Suspect rh_scaled values
DataStreams:nimmergesonde2maceM1.c1
Description:
MERGESONDE sometimes uses bad or questionable precipitable water vapor data to scale the 
relative humidity profiles provided by the rh_scaled field. In addition, this bad input 
data is not properly indicated by the vapor_source or qc_rh_scaled fields. This problem 
appears to typically occur when there is moisture impacting the microwave radiometer causing 
large spikes in brightness temperatures. During these periods the rh_scaled values are 
often saturated at 101% for much of the profile. 

A new version of the MERGESONDE VAP has corrected this problem, and these data will 
eventually be corrected by a reprocessing task.
Measurements:nimmergesonde2maceM1.c1:
  • vapor_source
  • rh_scaled


Back To Table of Contents