DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D151016.1 | OLI/KAZR/M1 - Clutter Filter On | olikazrgeM1.a1 | Does not affect quality |
D151103.1 | OLI/KAZR/M1 - Calibration, Grooming, and Alignment Period | olikazrgeM1.a1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/15/2015 | 0000 | 10/10/2015 | 1900 | Does not affect quality |
Subject: | OLI/KAZR/M1 - Clutter Filter On |
DataStreams: | olikazrgeM1.a1 |
Description: | The clutter filter was on during this period. The shift in background noise level on 10/10/2015 is resultant from switching the filter off. |
Measurements: | olikazrgeM1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/11/2015 | 0000 | 10/24/2015 | 2359 | Does not affect quality |
Subject: | OLI/KAZR/M1 - Calibration, Grooming, and Alignment Period |
DataStreams: | olikazrgeM1.a1 |
Description: | The calibration, grooming, and alignment for the SACR occurred during this period. The KAZR settings should not have changed during this period. |
Measurements: | olikazrgeM1.a1:
|