DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D160121.2 | ENA/AOSMET/C1 - Missing wind speed and direction data | enaaosmetC1.a1 | Missing |
D160208.2 | ENA/AOSMET/C1 - Reprocessed and Corrected: Wind direction off by 80 degrees | enaaosmetC1.a1 | Does not affect quality |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/12/2016 | 0526 | 01/19/2016 | 1130 | Missing |
02/03/2016 | 1615 | 02/08/2016 | 1650 | Missing |
Subject: | ENA/AOSMET/C1 - Missing wind speed and direction data |
DataStreams: | enaaosmetC1.a1 |
Description: | Wind speed and direction data are intermittently missing during this time. The sensor was replaced. |
Measurements: | enaaosmetC1.a1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/19/2016 | 1130 | 02/03/2016 | 1615 | Does not affect quality |
02/08/2016 | 1650 | 02/08/2016 | 1748 | Does not affect quality |
Subject: | ENA/AOSMET/C1 - Reprocessed and Corrected: Wind direction off by 80 degrees |
DataStreams: | enaaosmetC1.a1 |
Description: | DATA REPROCESSED and CORRECTED: An offset was loaded in the configuration settings of the wind sensor, so the wind direction was off by +80 degrees. The raw data were modified and were run through the ingest to correct the addressed issue. The reprocessed data were Archived in July 2016. Please retrieve the reprocessed data for use in your analysis. You may find these data using the ARM Discovery tool at the following link: http://www.archive.arm.gov/discovery/#v/results/s/finst::aos/fsite::ena/ffac::ena.C1 ORIGINAL DQR CATEGORY: Red( Incorrect) REPROCESSED and CORRECTED DATA ARCHIVED:2016-07 REPROCESS IDENTIFICATION NUMBER: RID 1425 --------------------------------------------------- --- ORIGINAL DQR DESCRIPTION --- --------------------------------------------------- An unintentional offset was loaded in the configuration settings of the wind sensor. Wind direction during this time is off by +80 degrees |
Measurements: | enaaosmetC1.a1:
|