Data Quality Reports for Session: 184413 User: wlj Completed: 03/21/2017


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D040608.2SGP/BRS/C1 - NIP sensor failuresgpbrsC1.00Missing
D050322.1SGP/BRS/C1 - low downwelling shortwave readingssgpbrsC1.00Suspect


DQRID : D040608.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/02/2004173406/15/20042010Missing
Subject:
SGP/BRS/C1 - NIP sensor failure
DataStreams:sgpbrsC1.00
Description:
Normal incidence values of downwelling shortwave radiation were
               reported as -9999 (missing).  The NIP instrument was damaged by
               lightning in the area near the time of failure.
Measurements:sgpbrsC1.00:
  • Raw data stream - documentation not supported


Back To Table of Contents

DQRID : D050322.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
04/18/2003000012/17/20042030Suspect
Subject:
SGP/BRS/C1 - low downwelling shortwave readings
DataStreams:sgpbrsC1.00
Description:
Downwelling shortwave (DS) values frequently drop below -10 W/m^2 at night, and are 
consistently 20-40 W/m^2 less than the calculated downwelling shortwave during the day in 
clear-sky conditions. Corrective maintenance on 12/17/2004 corrected this offset.  It is not 
clear which CM action corrected the problem since the DS instrument cable was grounded to 
a new location and the DS ventilator fan was found in poor condition and was replaced.  
Either of these issues could have led to the problem observed in this instrument.
Measurements:sgpbrsC1.00:
  • Raw data stream - documentation not supported


Back To Table of Contents



END OF DATA