DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D130110.2 | NSA/ECOR/E10 - Missing data | nsa30ecorE10.b1 | Missing |
D130411.1 | NSA/ECOR/E10 - CO2 and H2O Fluxes Missing | nsa30ecorE10.b1 | Incorrect |
D130411.2 | NSA/ECOR/E10 - H2O fluxes missing | nsa30ecorE10.b1 | Incorrect |
D131005.2 | NSA/ECOR/E10 - Missing pressure and temperature data | nsa30ecorE10.b1 | Missing |
D140206.1 | NSA/ECOR/E10 - Missing data | nsa30ecorE10.b1 | Missing |
D150212.2 | NSA/ECOR/E10 - Data Missing | nsa30ecorE10.b1 | Missing |
D150218.1 | NSA/ECOR/E10 - All Data Missing | nsa30ecorE10.b1 | Missing |
D150331.4 | NSA/ECOR/E10 - Pressure and Temperature Measurements Missing | nsa30ecorE10.b1 | Missing |
D150717.2 | NSA/ECOR/E10 - Some Measurements Incorrect During Servicing | nsa30ecorE10.b1 | Incorrect |
D160718.2 | NSA/ECOR/TSI/C1/E10 - Data Missing | nsa30ecorE10.b1 | Missing |
D161017.4 | NSA/ECOR/E10 - Sonic Temperature Fluctuations | nsa30ecorE10.b1 | Suspect |
D161202.2 | NSA/ECOR/E10 - Sensible and Latent Heat Fluxes Incorrect | nsa30ecorE10.b1 | Incorrect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/22/2012 | 2200 | 01/03/2013 | 1600 | Missing |
Subject: | NSA/ECOR/E10 - Missing data |
DataStreams: | nsa30ecorE10.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/03/2013 | 1630 | 04/09/2013 | 1935 | Incorrect |
Subject: | NSA/ECOR/E10 - CO2 and H2O Fluxes Missing |
DataStreams: | nsa30ecorE10.b1 |
Description: | The CO2/H2O sensor head cable was disconnected when the ECOR tripod failure occurred on 12/22/2012. The problem was rectified by plugging in the cable and cleaning the LI-7500 sensor head windows. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/20/2012 | 0100 | 12/22/2012 | 2130 | Incorrect |
Subject: | NSA/ECOR/E10 - H2O fluxes missing |
DataStreams: | nsa30ecorE10.b1 |
Description: | H2O fluxes were missing because of sea salt and frost on the sensor head windows. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/26/2013 | 0100 | 10/01/2013 | 1930 | Missing |
Subject: | NSA/ECOR/E10 - Missing pressure and temperature data |
DataStreams: | nsa30ecorE10.b1 |
Description: | IRGA temperature and pressure were missing during this period. Power cycling the IRGA solved this problem. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/10/2013 | 2300 | 02/05/2014 | 2330 | Missing |
Subject: | NSA/ECOR/E10 - Missing data |
DataStreams: | nsa30ecorE10.b1 |
Description: | All data except for temperature and pressure were missing because a sonic head transducer was broken/missing. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/28/2015 | 2030 | 01/30/2015 | 1000 | Missing |
Subject: | NSA/ECOR/E10 - Data Missing |
DataStreams: | nsa30ecorE10.b1 |
Description: | All or most of the data was missing during this period. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
02/09/2015 | 1130 | 02/16/2015 | 0700 | Missing |
Subject: | NSA/ECOR/E10 - All Data Missing |
DataStreams: | nsa30ecorE10.b1 |
Description: | The data is missing for this period, except for a few hours on 2/10. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/27/2015 | 1730 | 03/12/2015 | 2000 | Missing |
Subject: | NSA/ECOR/E10 - Pressure and Temperature Measurements Missing |
DataStreams: | nsa30ecorE10.b1 |
Description: | Pressure and temperature measurements returned after moving the IRGA serial connector to a different port of the Rocketport serial hub. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/15/2015 | 1630 | 07/15/2015 | 1830 | Incorrect |
Subject: | NSA/ECOR/E10 - Some Measurements Incorrect During Servicing |
DataStreams: | nsa30ecorE10.b1 |
Description: | Some measurements were incorrect during servicing of the system. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/12/2016 | 1510 | 07/15/2016 | 0000 | Missing |
Subject: | NSA/ECOR/TSI/C1/E10 - Data Missing |
DataStreams: | nsa30ecorE10.b1 |
Description: | Site data systems were being upgraded during this time. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/27/2016 | 0000 | 10/12/2016 | 0700 | Suspect |
Subject: | NSA/ECOR/E10 - Sonic Temperature Fluctuations |
DataStreams: | nsa30ecorE10.b1 |
Description: | Sonic temperature fluctuated at times. The fluctuations occurred slowly, so as to not affect the calculation of sensible heat flux. |
Measurements: | nsa30ecorE10.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/28/2016 | 0000 | 10/29/2016 | 2330 | Incorrect |
Subject: | NSA/ECOR/E10 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | nsa30ecorE10.b1 |
Description: | Sensible and latent heat fluxes were incorrect when the CO2/H2O analyzer and sonic anemometer were covered by frost, ice, or snow. |
Measurements: | nsa30ecorE10.b1:
|