DQR ID | Subject | Data Streams Affected | Data Quality Metric |
---|---|---|---|
D060828.2 | SGP/IRT/C1 - UPS failing | sgpirt10mC1.b1 | Suspect |
D120113.6 | SGP/IRT/C1 - Noisy 10m IRT data | sgpirt10mC1.b1 | Incorrect |
D121022.1 | SGP/IRT/C1 - Measurement range | sgpirt10mC1.b1 | Suspect |
D130211.1 | SGP/IRT/C1 - 10m IRT ground surface temperature | sgpirt10mC1.b1 | Does not affect quality |
D130806.2 | SGP/IRT/C1 - Noisy data | sgpirt10mC1.b1 | Suspect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/26/2006 | 0853 | 09/18/2006 | 1530 | Suspect |
Subject: | SGP/IRT/C1 - UPS failing |
DataStreams: | sgpirt10mC1.b1 |
Description: | The IRT data were intermittently bad during this period due to a failing UPS. The problem was corrected by replacing the UPS. |
Measurements: | sgpirt10mC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/03/2012 | 1530 | 01/04/2012 | 2030 | Incorrect |
Subject: | SGP/IRT/C1 - Noisy 10m IRT data |
DataStreams: | sgpirt10mC1.b1 |
Description: | The 10M IRT surface temperatures were very noisy because the connection to the data logger had become loose. |
Measurements: | sgpirt10mC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/25/2012 | 1800 | 08/04/2012 | 2059 | Suspect |
Subject: | SGP/IRT/C1 - Measurement range |
DataStreams: | sgpirt10mC1.b1 |
Description: | The ground surface temperature exceeded the maximum measurement of 50C on some days. The maximum was increased to 60C for IRT10m on 10/1/2012 at 15:25 and for IRT25m on 10/9/2012 at 21:45. |
Measurements: | sgpirt10mC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/11/2012 | 0750 | 02/08/2013 | 1525 | Does not affect quality |
Subject: | SGP/IRT/C1 - 10m IRT ground surface temperature |
DataStreams: | sgpirt10mC1.b1 |
Description: | The 10m IRT was measuring lower ground surface temperature than the 25m IRT. The lens was cleaned on 12/19/2012 and replaced on 2/8/2013 but the difference in temperature appears to be due to the seasonal difference in surface cover - tall grass vesus bare soil. |
Measurements: | sgpirt10mC1.b1:
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/05/2011 | 1603 | 07/14/2011 | 0303 | Suspect |
08/03/2011 | 2242 | 08/12/2011 | 0627 | Suspect |
07/26/2011 | 2021 | 07/26/2011 | 2310 | Suspect |
Subject: | SGP/IRT/C1 - Noisy data |
DataStreams: | sgpirt10mC1.b1 |
Description: | The power supplied to the data logger was very "noisy" causing the surface temperature measurements to also be "noisy". |
Measurements: | sgpirt10mC1.b1:
|