Data Quality Reports for Session: 185156 User: zhaoz1 Completed: 04/21/2017


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D021113.2SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30baebbrE26.c1Does not affect quality
D050114.7SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9 - BA EBBR VAP Bulk Aerodynamicssgp30baebbrE26.c1Incorrect


DQRID : D021113.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/01/1995000006/18/20032359Does not affect quality
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30baebbrE26.c1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30baebbrE26.c1:
  • cs1
  • cs3
  • cs2
  • cs4
  • cs5


Back To Table of Contents

DQRID : D050114.7
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/01/1995000006/30/20032330Incorrect
Subject:
SGP/EBBR/E13/E15/E20/E22/E26/E4/E7/E8/E9  - BA EBBR VAP Bulk Aerodynamics
DataStreams:sgp30baebbrE26.c1
Description:
Fixed AEM and wind speed sensor heights were improperly used in the calculation of bulk 
aerodynamic sensible and latent heat fluxes instead of site specific heights.

This resulted in either under-estimation or over-estimation of the sensible and latent 
heat fluxes.
Measurements:sgp30baebbrE26.c1:
  • austar
  • Heat flux, latent, best estimate(ecomb)
  • Heat flux, sensible, best estimate(hcomb)
  • Heat flux, latent, aerodynamic(ale)
  • Heat flux, sensible, aerodynamic(ah)


Back To Table of Contents