Data Quality Reports for Session: 185416 User: masons1 Completed: 05/05/2017


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D160401.9AWR/MWR/M1 - Thermal instabilityawrmwrlosM1.b1Suspect
D160426.1AWR/MWR/M1 - Reprocess: Incorrect retrievalsawrmwrlosM1.b1Incorrect
D160621.2AWR/MWR/M1 - Instrument thermally unstableawrmwrlosM1.b1Incorrect
D160715.6AWR/MWR/M1 - Thermal instabilityawrmwrlosM1.b1Suspect


DQRID : D160401.9
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/20/2016000003/21/20162359Suspect
Subject:
AWR/MWR/M1 - Thermal instability
DataStreams:awrmwrlosM1.b1
Description:
The radiometer had problems maintaining thermal control. The radiometer set point was 
lowered 10 degrees to 318 K on 3/21/2016
Measurements:awrmwrlosM1.b1:
  • tnd31
  • tnd23
  • Mean 31.4 GHz sky brightness temperature(tbsky31)
  • Water, liquid, total along line-of-sight path, mean, 5-min avg(liq)
  • qc_tkxc
  • qc_tknd
  • Total water vapor along LOS path(vap)
  • 23.8 GHz sky brightness temperature(tbsky23)


Back To Table of Contents

DQRID : D160426.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/01/2016000001/13/20172359Incorrect
Subject:
AWR/MWR/M1 - Reprocess: Incorrect retrievals
DataStreams:awrmwrlosM1.b1
Description:
PWV and LWP retrievals are incorrect. Data will be reprocessed at the end of the 
deployment using coefficients derived from the radiosondes launched at the site.
Measurements:awrmwrlosM1.b1:
  • Water, liquid, total along line-of-sight path, mean, 5-min avg(liq)
  • Total water vapor along LOS path(vap)


Back To Table of Contents

DQRID : D160621.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/12/2016030006/14/20160000Incorrect
Subject:
AWR/MWR/M1 - Instrument thermally unstable
DataStreams:awrmwrlosM1.b1
Description:
The radiometer was thermally unstable.
Measurements:awrmwrlosM1.b1:
  • tnd31
  • tnd23
  • tknd
  • Mean 31.4 GHz sky brightness temperature(tbsky31)
  • tkxc
  • Water, liquid, total along line-of-sight path, mean, 5-min avg(liq)
  • tnd_nom23
  • tnd_nom31
  • Total water vapor along LOS path(vap)
  • 23.8 GHz sky brightness temperature(tbsky23)


Back To Table of Contents

DQRID : D160715.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
07/04/2016142007/05/20162310Suspect
Subject:
AWR/MWR/M1 - Thermal instability
DataStreams:awrmwrlosM1.b1
Description:
The radiometer was thermally unstable.
Measurements:awrmwrlosM1.b1:
  • tnd31
  • tnd23
  • tknd
  • Mean 31.4 GHz sky brightness temperature(tbsky31)
  • tkxc
  • Water, liquid, total along line-of-sight path, mean, 5-min avg(liq)
  • tnd_nom23
  • tnd_nom31
  • Total water vapor along LOS path(vap)
  • 23.8 GHz sky brightness temperature(tbsky23)


Back To Table of Contents



END OF DATA