Data Quality Reports for Session: 186103 User: stemmlerj2 Completed: 06/12/2017


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected Data Quality Metric
D160525.1ASI/MET/M1 - Damaged cableasimetM1.b1Incorrect
D160526.5ASI/MET/M1 - Site setupasimetM1.b1Incorrect
D160526.6ASI/MET/M1 - Broken wireasimetM1.b1Incorrect
D160526.7ASI/MET/M1 - Temp/Humidity sensor not at standard heightasimetM1.b1Does not affect quality


DQRID : D160525.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/23/2016231305/25/20161106Incorrect
Subject:
ASI/MET/M1 - Damaged cable
DataStreams:asimetM1.b1
Description:
Damage to the temp/humidity instrument cable caused incorrect readings during this time.
Measurements:asimetM1.b1:
  • Temperature mean(temp_mean)
  • Vapor pressure mean, calculated(vapor_pressure_mean)
  • vapor_pressure_std
  • Humidity, relative, at 2-m height, 1-min avg(rh_mean)
  • rh_std
  • temp_std


Back To Table of Contents

DQRID : D160526.5
Start DateStart TimeEnd DateEnd Time Data Quality Metric
04/23/2016000004/26/20160931Incorrect
Subject:
ASI/MET/M1 - Site setup
DataStreams:asimetM1.b1
Description:
Instruments were not yet aligned or in their permanent locations. Data during this time 
should not be used.
Measurements:asimetM1.b1:
  • pwd_pw_code_inst
  • qc_pwd_cumul_rain
  • qc_logger_temp
  • ORG precipitation rate mean(org_precip_rate_mean)
  • qc_pwd_precip_rate_mean_1min
  • qc_rh_mean
  • qc_wspd_vec_mean
  • pwd_pw_code_15min
  • qc_pwd_pw_code_1hr
  • time_offset
  • base_time
  • pwd_err_code
  • vapor_pressure_std
  • qc_wdir_vec_mean
  • wdir_vec_std
  • logger_volt
  • North latitude(lat)
  • qc_org_precip_rate_mean
  • Wind speed, lower, 1-min avg(wspd_arith_mean)
  • qc_logger_volt
  • qc_pwd_mean_vis_1min
  • Atmospheric pressure(atmos_pressure)
  • PWD 1 minute mean precipitation rate(pwd_precip_rate_mean_1min)
  • qc_atmos_pressure
  • Humidity, relative, at 2-m height, 1-min avg(rh_mean)
  • East longitude(lon)
  • qc_temp_mean
  • qc_pwd_pw_code_15min
  • logger_temp
  • PWD 1 minute mean visibility(pwd_mean_vis_1min)
  • Wind speed vector mean(wspd_vec_mean)
  • qc_vapor_pressure_mean
  • pwd_cumul_rain
  • qc_wspd_arith_mean
  • Temperature mean(temp_mean)
  • Altitude above mean sea level(alt)
  • Vapor pressure mean, calculated(vapor_pressure_mean)
  • PWD 10 minute mean visibility(pwd_mean_vis_10min)
  • qc_pwd_pw_code_inst
  • Wind direction vector mean(wdir_vec_mean)
  • rh_std
  • time
  • pwd_pw_code_1hr
  • qc_pwd_mean_vis_10min
  • temp_std


Back To Table of Contents

DQRID : D160526.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
04/26/2016093105/10/20161612Incorrect
Subject:
ASI/MET/M1 - Broken wire
DataStreams:asimetM1.b1
Description:
A wire on the sensor cable broke during this time and data are incorrect.
Measurements:asimetM1.b1:
  • Temperature mean(temp_mean)
  • Vapor pressure mean, calculated(vapor_pressure_mean)
  • vapor_pressure_std
  • Humidity, relative, at 2-m height, 1-min avg(rh_mean)
  • rh_std
  • temp_std


Back To Table of Contents

DQRID : D160526.7
Start DateStart TimeEnd DateEnd Time Data Quality Metric
04/26/2016093105/25/20161100Does not affect quality
Subject:
ASI/MET/M1 - Temp/Humidity sensor not at standard height
DataStreams:asimetM1.b1
Description:
Prior to 5/25, the temp/humidity sensor was mounted at 3 meters. On 5/25 the sensor was 
lowered to the standard height of 2 meters. No significant impact on data is expected.
Measurements:asimetM1.b1:
  • Temperature mean(temp_mean)
  • Vapor pressure mean, calculated(vapor_pressure_mean)
  • Humidity, relative, at 2-m height, 1-min avg(rh_mean)


Back To Table of Contents