Data Quality Report for Order ID: 187106
User ID: zhengg1    Date completed: 2017-08-07
All DQRs
DQR ID Subject Affected Data Streams Data Quality Metric
D170802.8 ENA/HTDMA/NEPHELOMETER/C1 - No dry air supply enaaosnephwet1mC1.b1 Suspect
D170705.4 ENA/HTDMA/NEPHELOMETER/C1 - Dry air low pressure enaaosnephwet1mC1.b1 Suspect
D170731.1 ENA/CCN/C1 - Instrument in safe mode enaaosccn100C1.01 Incorrect
D170726.7 ENA/CO-ANALYZER/C1 - Reprocess: Valve position fields incorrect enaaoscoC1.b1 Incorrect
D170724.3 ENA/ACSM/C1 - Low inlet pressure enaaosacsmC1.a1 Suspect
 
DQR ID: D170802.8    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2017-08-02 12:00:00 2017-08-02 14:05:00 Suspect
Subject: ENA/HTDMA/NEPHELOMETER/C1 - No dry air supply
Affected Datastreams: enaaosnephwet1mC1.b1
Description Dry air supply failed. Instruments working normally, but with a different RH than specified.
Measurements
  • qc_Bbs_R_Dry_Neph3W (Quality check results on field: Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at dry or reference RH)
  • lamp_current (Lamp current)
  • qc_Bbs_G_Dry_Neph3W (Quality check results on field: Aerosol back-hemispheric light scattering coefficient, nominal green wavelength at dry or reference RH)
  • Bbs_G_Wet_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal green wavelength at ramped RH)
  • qc_T_Neph_Dry (Quality check results on field: Sample temperature inside reference nephelometer)
  • qc_Bbs_R_Wet_Neph3W (Quality check results on field: Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at ramped RH)
  • qc_T_Neph_Inlet_Wet (Quality check results on field: Temperature at humidified nephelometer inlet)
  • seconds_after_transition (Seconds since last impactor transition)
  • RH_Neph_Wet (Relative humidity inside humidified nephelometer)
  • qc_Bs_R_Dry_Neph3W (Quality check results on field: Aerosol total light scattering coefficient, nominal red wavelength at dry or reference RH)
  • qc_RH_Neph_Wet (Quality check results on field: Relative humidity inside humidified nephelometer)
  • qc_Bs_G_Wet_Neph3W (Quality check results on field: Aerosol total light scattering coefficient, nominal green wavelength at ramped RH)
  • base_time (Base time in Epoch)
  • bin (Bin number)
  • qc_impactor_state (Quality check results on field: Impactor particle size cut)
  • qc_Bbs_B_Dry_Neph3W (Quality check results on field: Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength at dry or reference RH)
  • scan_max_diameter_setting (Maximum aerosol particle diameter instrument setting)
  • T_Neph_Wet (Sample temperature inside humidified nephelometer)
  • qc_impactor_state (Quality check results on field: Impactor state in terms of aerodynamic diameter cut off)
  • Bbs_G_Dry_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal green wavelength at dry or reference RH)
  • Bs_G_Dry_Neph3W (Aerosol total light scattering coefficient, nominal green wavelength at dry or reference RH)
  • lat (North latitude)
  • scan_min_diameter_setting (Minimum aerosol particle diameter instrument setting)
  • qc_Bs_B_Dry_Neph3W (Quality check results on field: Aerosol total light scattering coefficient, nominal blue wavelength at dry or reference RH)
  • qc_Bs_B_Wet_Neph3W (Quality check results on field: Aerosol total light scattering coefficient, nominal blue wavelength at ramped RH)
  • total_concentration (Total scan concentration over all bins)
  • mode_flag (Instrument operating mode)
  • qc_P_Neph_Wet (Quality check results on field: Pressure inside humidified nephelometer)
  • Bs_B_Wet_Neph3W (Aerosol total light scattering coefficient, nominal blue wavelength at ramped RH)
  • P_Neph_Wet (Pressure inside humidified nephelometer)
  • density_correction_factor (Correction to humidified nephelometer measurements to standard temperature and pressure)
  • qc_Bbs_B_Wet_Neph3W (Quality check results on field: Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength at ramped RH)
  • instrument_state (Instrument state)
  • time_offset (Time offset from base_time)
  • Bs_G_Wet_Neph3W (Aerosol total light scattering coefficient, nominal green wavelength at ramped RH)
  • scan_time_setting (Humidified DMA scanning time instrument setting)
  • sample_flow (Aerosol sample flow rate)
  • P_Neph_Dry (Pressure inside reference nephelometer)
  • alt (Altitude above mean sea level)
  • Bs_R_Wet_Neph3W (Aerosol total light scattering coefficient, nominal red wavelength at ramped RH)
  • density_correction_factor (Correction to ambient nephelometer measurements to standard temperature and pressure)
  • Bbs_B_Dry_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength at dry or reference RH)
  • qc_RH_Neph_Dry (Quality check results on field: Relative humidity inside reference nephelometer)
  • qc_T_Neph_Inlet_Dry (Quality check results on field: Temperature at reference nephelometer inlet)
  • scan_type (Sampling mode scan type)
  • RH_Neph_Dry (Relative humidity inside reference nephelometer)
  • dry_rh_setting (Dry aerosol particle relative humidity instrument setting)
  • time (Time offset from midnight)
  • lamp_voltage (Lamp voltage)
  • humid_rh (Humid aerosol particle relative humidity)
  • dry_diameter_setting (Dry aerosol diameter size instrument setting)
  • bin_center (Bin center value)
  • atomizer (Atomizer calibration status)
  • impactor_state (Impactor particle size cut)
  • Bbs_R_Dry_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at dry or reference RH)
  • T_Neph_Inlet_Dry (Temperature at reference nephelometer inlet)
  • T_Neph_Inlet_Wet (Temperature at humidified nephelometer inlet)
  • impactor_state (Impactor state in terms of aerodynamic diameter cut off)
  • num_bins (Number of distribution bins)
  • Bbs_B_Wet_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength at ramped RH)
  • qc_T_Neph_Wet (Quality check results on field: Sample temperature inside humidified nephelometer)
  • T_Neph_Dry (Sample temperature inside reference nephelometer)
  • Bbs_R_Wet_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at ramped RH)
  • seconds_after_transition (seconds since last impactor transition)
  • qc_P_Neph_Dry (Quality check results on field: Pressure inside reference nephelometer)
  • time_bounds (Time cell bounds)
  • bin_width (Bin width)
  • qc_Bs_G_Dry_Neph3W (Quality check results on field: Aerosol total light scattering coefficient, nominal green wavelength at dry or reference RH)
  • aerosol_concentration (Concentration of aerosol)
  • Bs_R_Dry_Neph3W (Aerosol total light scattering coefficient, nominal red wavelength at dry or reference RH)
  • Bs_B_Dry_Neph3W (Aerosol total light scattering coefficient, nominal blue wavelength at dry or reference RH)
  • qc_Bs_R_Wet_Neph3W (Quality check results on field: Aerosol total light scattering coefficient, nominal red wavelength at ramped RH)
  • lon (East longitude)
  • qc_Bbs_G_Wet_Neph3W (Quality check results on field: Aerosol back-hemispheric light scattering coefficient, nominal green wavelength at ramped RH)
 
DQR ID: D170705.4    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2017-06-29 11:00:00 2017-07-01 08:00:00 Suspect
2017-06-20 08:00:00 2017-06-20 13:00:00 Suspect
2017-06-27 15:00:00 2017-06-28 13:00:00 Suspect
2017-06-24 16:00:00 2017-06-26 09:00:00 Suspect
Subject: ENA/HTDMA/NEPHELOMETER/C1 - Dry air low pressure
Affected Datastreams: enaaosnephwet1mC1.b1
Description Dry air system efficiency low, not able to keep air pressure up. HT-DMA and humidigraph drying efficiency affected. HT-DMA flow stability affected. Humidigraph data unaffected, just RH is different than nominal. Effect on HT-DMA data is uncertain.
Measurements
  • lamp_current (Lamp current)
  • Bbs_G_Wet_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal green wavelength at ramped RH)
  • seconds_after_transition (Seconds since last impactor transition)
  • RH_Neph_Wet (Relative humidity inside humidified nephelometer)
  • bin (Bin number)
  • scan_max_diameter_setting (Maximum aerosol particle diameter instrument setting)
  • T_Neph_Wet (Sample temperature inside humidified nephelometer)
  • scan_min_diameter_setting (Minimum aerosol particle diameter instrument setting)
  • total_concentration (Total scan concentration over all bins)
  • mode_flag (Instrument operating mode)
  • Bs_B_Wet_Neph3W (Aerosol total light scattering coefficient, nominal blue wavelength at ramped RH)
  • P_Neph_Wet (Pressure inside humidified nephelometer)
  • density_correction_factor (Correction to humidified nephelometer measurements to standard temperature and pressure)
  • instrument_state (Instrument state)
  • sample_flow (Aerosol sample flow rate)
  • Bs_G_Wet_Neph3W (Aerosol total light scattering coefficient, nominal green wavelength at ramped RH)
  • scan_time_setting (Humidified DMA scanning time instrument setting)
  • Bs_R_Wet_Neph3W (Aerosol total light scattering coefficient, nominal red wavelength at ramped RH)
  • density_correction_factor (Correction to ambient nephelometer measurements to standard temperature and pressure)
  • scan_type (Sampling mode scan type)
  • dry_rh_setting (Dry aerosol particle relative humidity instrument setting)
  • lamp_voltage (Lamp voltage)
  • humid_rh (Humid aerosol particle relative humidity)
  • dry_diameter_setting (Dry aerosol diameter size instrument setting)
  • bin_center (Bin center value)
  • atomizer (Atomizer calibration status)
  • impactor_state (Impactor particle size cut)
  • T_Neph_Inlet_Wet (Temperature at humidified nephelometer inlet)
  • impactor_state (Impactor state in terms of aerodynamic diameter cut off)
  • num_bins (Number of distribution bins)
  • Bbs_R_Wet_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal red wavelength at ramped RH)
  • seconds_after_transition (seconds since last impactor transition)
  • bin_width (Bin width)
  • aerosol_concentration (Concentration of aerosol)
  • Bbs_B_Wet_Neph3W (Aerosol back-hemispheric light scattering coefficient, nominal blue wavelength at ramped RH)
 
DQR ID: D170731.1    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2017-07-28 23:00:00 2017-07-29 00:00:10 Incorrect
2017-07-29 07:00:00 2017-07-29 08:00:00 Incorrect
Subject: ENA/CCN/C1 - Instrument in safe mode
Affected Datastreams: enaaosccn100C1.01
Description Instrument went into safe mode due to low counts. Instrument was working fine, just the ambient aerosol concentration was very low.
Measurements
  • CCN_T_read_TEC2 (AOS CCN observed temperature at middle of column)
  • CCN_T_nafion_set (AOS CCN set temperature for the Nafion humidifier)
  • seconds_after_transition (Seconds since last impactor transition)
  • CCN_Q_sample (AOS CCN volumetric flowrate of sample air)
  • N_CCN_dN (AOS CCN droplet count by bin size)
  • CCN_OPC_set (AOS CCN set point temperature for the optical particle counter (OPC))
  • N_CCN_bin_number (AOS bin number of lowest channel of OPC include in summation of N_CCN)
  • CCN_T_read_TEC1 (AOS CCN observed temperature at top of column)
  • base_time (Base time in Epoch)
  • CCN_T_sample (AOS CCN temperature of sample air entering the column)
  • size_bin_bounds (Droplet bin bounds)
  • lat (North latitude)
  • CCN_T_inlet_set (AOS CCN set point temperature for the inlet manifold)
  • CCN_T_set_TEC2 (AOS CCN set point for temperature at middle of column)
  • CCN_supersaturation_set_point (AOS CCN sample supersaturation set point value reported by instrument)
  • CCN_proportional_valve_voltage (CCN Proportional valve voltage)
  • CCN_overflow (Number of particles that are larger than 10um)
  • time_offset (Time offset from base_time)
  • CCN_laser_current (AOS CCN OPC laser current)
  • alt (Altitude above mean sea level)
  • CCN_baseline_monitor (AOS CCN voltage used by DMT for OPC diagnostic purposes)
  • CCN_temp_unstable (AOS CCN logical value, indicating whether the instrument has reached thermal gradient stabilization and is within 0.4 degrees C of the set point)
  • size_bin (Size bins for CCN droplet count)
  • time (Time offset from midnight)
  • CCN_alarm_code (CCN alarm code expressed as a summation of powers of 2. 0 indicates no detected problem)
  • CCN_T_set_TEC1 (AOS CCN set point for temperature at top of column)
  • CCN_T_OPC (AOS CCN temperature of the optical particle counter)
  • CCN_T_inlet (AOS CCN temperature of sample air at entrance to instrument)
  • seconds_after_transition (seconds since last impactor transition)
  • CCN_P_sample (AOS CCN sample pressure)
  • CCN_T_set_TEC3 (AOS CCN set point for temperature at bottom of column)
  • time_bounds (Time cell bounds)
  • CCN_first_stage_monitor_voltage (First stage monitor voltage)
  • N_CCN (AOS number concentration of CCN)
  • CCN_Q_sheath (AOS CCN volumetric flowrate of sheath air)
  • CCN_T_read_TEC3 (AOS CCN (read) temperature at bottom of column)
  • CCN_temperature_gradient (Temperature difference between CCN_t_set_TEC3 and CCN_t_set_TEC1)
  • CCN_T_nafion (AOS CCN Nafion temperature)
  • lon (East longitude)
 
DQR ID: D170726.7    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2017-06-13 18:00:00 2017-07-26 23:59:59 Incorrect
Subject: ENA/CO-ANALYZER/C1 - Reprocess: Valve position fields incorrect
Affected Datastreams: enaaoscoC1.b1
Description A bug in the a1- and b1-level AOS CO ingest processes caused the valve position fields to be incorrect. This had the trickle-down effect of flagging the primary fields as incorrect via embedded QC in the b1-level product. Reprocessing is being requested now that this ingest bug has been corrected.
Measurements
  • valve_position_MFC_2 (Valve position mass flow controller 2)
  • valve_position_MFC_1 (Valve position for mass flow controller 1)
 
DQR ID: D170724.3    (Back to Top)
Start Date Start Time End Date End Time Data Quality Metric
2017-07-19 00:27:00 2017-07-20 12:34:00 Suspect
Subject: ENA/ACSM/C1 - Low inlet pressure
Affected Datastreams: enaaosacsmC1.a1
Description The data are questionable because of low inlet pressure. Signal to noise will be low. Data probably cannot be used for PMF.
Measurements
  • sulfate (Mass concentration of sulfate, ambient aerosol in air.)
  • flow_rate (Flow rate, calculated from calibration and inlet pressure)
  • nitrate (Mass concentration of nitrate, ambient aerosol in air.)
  • vaporizer (Vaporizer)
  • inlet_closed (Inlet closed)
  • total_organics (Mass concentration of total organics, ambient aerosol in air)
  • ammonium (Mass concentration of ammonium, ambient aerosol in air.)
  • chloride (Mass concentration of chloride, ambient aerosol in air.)
  • emission_current (Emission current)
  • inlet_open (Inlet open)