DQR ID | Subject | Affected Data Streams | Data Quality Metric |
---|---|---|---|
D140905.1 | MAO/ECOR/M1 - Data Missing | mao30ecorM1.b1 | Missing |
D140625.1 | MAO/ECOR/M1 - Fluxes and wind measurements incorrect. | mao30ecorM1.b1 | Incorrect |
D140825.3 | MAO/ECOR/M1 - Latent Heat Flux and CO2 Flux Incorrect | mao30ecorM1.b1 | Incorrect |
D150105.1 | MAO/ECOR/M1 - All Data Missing | mao30ecorM1.b1 | Missing |
D140529.1 | MAO/ECOR/M1 - CO2/H2O Means, CO2 flux, and Latent Heat Flux Incorrect | mao30ecorM1.b1 | Incorrect |
D150402.3 | MAO/ECOR/M1 - Missing Data | mao30ecorM1.b1 | Missing |
D140529.2 | MAO/ECOR/M1 - Wind Direction Too Low by About 10 Degrees. | mao30ecorM1.b1 | Incorrect |
D150512.1 | MAO/ECOR/M1 - Latent Heat Flux and Water Vapor Density Incorrect | mao30ecorM1.b1 | Incorrect |
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-08-27 | 12:00:00 | 2014-08-28 | 20:30:00 | Missing |
Subject: | MAO/ECOR/M1 - Data Missing |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | All data was missing during then stated period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-06-21 | 01:30:00 | 2014-06-21 | 14:00:00 | Incorrect |
Subject: | MAO/ECOR/M1 - Fluxes and wind measurements incorrect. |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | The measurements were incorrect because the ECOR tripod was tipped over. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-06-21 | 01:30:00 | 2014-08-24 | 15:00:00 | Incorrect |
Subject: | MAO/ECOR/M1 - Latent Heat Flux and CO2 Flux Incorrect |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | The analog outputs of the H2O/CO2 analyzer were not working; therefore latent heat flux and CO2 flux were incorrect during the specified period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-12-22 | 13:00:00 | 2014-12-24 | 14:00:00 | Missing |
Subject: | MAO/ECOR/M1 - All Data Missing |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | All data missing because of a broken sonic breakout box wire lead. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-04-03 | 18:00:00 | 2014-05-21 | 14:00:00 | Incorrect |
Subject: | MAO/ECOR/M1 - CO2/H2O Means, CO2 flux, and Latent Heat Flux Incorrect |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | All CO2 and water vapor means, CO2 flux, and latent heat flux are incorrect for the period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-01-20 | 08:00:00 | 2015-03-27 | 22:00:00 | Missing |
Subject: | MAO/ECOR/M1 - Missing Data |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | All data missing for the stated period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2014-04-03 | 18:00:00 | 2014-05-22 | 15:30:00 | Incorrect |
Subject: | MAO/ECOR/M1 - Wind Direction Too Low by About 10 Degrees. |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | ECOR wind direction was about 10 degrees low during this period. |
Measurements |
|
Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
2015-04-05 | 19:00:00 | 2015-05-11 | 16:30:00 | Incorrect |
Subject: | MAO/ECOR/M1 - Latent Heat Flux and Water Vapor Density Incorrect |
---|---|
Affected Datastreams: | mao30ecorM1.b1 |
Description | Latent heat flux was incorrect because the water vapor density was not being correctly measured. |
Measurements |
|